Mechanical characterization of anti-infectious, anti-allergic, and bioactive coatings on orthopedic implant surfaces
Source abstract
Abstract
In total joint replacement much effort has been made to reduce implant loosening. We investigated different implant coatings (copper integrated titanium dioxide (TiO2–Cu), titanium nitride (TiN), plasma polymerized allylamine (PPAAm), and calcium phosphate (CaP)) regarding the adhesion strength and wear resistance. Standardized scratch and adhesive tests were applied. Abrasive wear was measured with artificial bone and bone cement using a special testing machine. All tested coatings have higher bonding strengths than the 22 N/mm2 required for medical implant surface coatings by ASTM standard 4711-F. Using bone cement, wear testing revealed higher wear rates in most cases. Polished surfaces reduce the amount of wear, whereas rough surfaces highly increase the wear rate due to three-body wear, especially ceramic surfaces. In general, the application of bone cement in conjunction with modified implant surfaces can lead to an increase in wear rate.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Metal and Thin Film Mechanics · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Zeiler G, Distler A (2000) Biomaterialien 1:1910.1515/BIOMAT.2000.1.1.19 ↗
2. Schuh A, Thomas P, Holzwarth U et al (2004) Orthopäde 33:727
3. Malchau H, Herberts P, Eisler T et al (2002) J Bone Joint Surg Am 84:210.2106/00004623-200200002-00002 ↗
4. Darouiche RO (2004) N Engl J Med 350(14):142210.1056/NEJMra035415 ↗
5. Holzwarth U, Thomas P, Kachler W et al (2005) Orthopäde 34:104610.1007/s00132-005-0849-y ↗
6. Schuh A, Thomas P, Kachler W et al (2005) Orthopäde 34:32710.1007/s00132-005-0764-2 ↗
7. Doehring TC, Rubash HE, Dore DE (1999) Clin Orthop Relat Res 362:23010.1097/00003086-199905000-00032 ↗
8. Widmer KH, Zurfluh B, Morscher EW (1997) Orthopäde 26:181
9. Bader R, Steinhauser E, Zimmermann S et al (2004) J Mater Sci: Mater Med 15:711
10. Steinau HU, Schackert HK, Bauer H (2007) Chirurgisches Forum 2007 für experimentelle und klinische Forschung. Springer, Berlin10.1007/978-3-540-71123-0 ↗
11. Thull R (2003) Orthopäde 32:5110.1007/s00132-002-0412-z ↗
12. Piotrowski A, Bensmann G (2002) Mat-wiss u Werkstofftech 33:46410.1002/1521-4052(200208)33:8<464::AID-MAWE464>3.0.CO;2-4 ↗
13. Gristina AG, Naylor P, Myrvik Q (1988–1989) Med Prog Technol 14:205
14. Gollwitzer H, Thomas P, Diehl P et al (2005) J Orthop Res 23(4):80210.1016/j.orthres.2005.02.003 ↗
15. Cook G, Costerton JW, Darouiche RO (2000) Int J Antimicrob Agents 13(3):16910.1016/S0924-8579(99)00120-X ↗
16. Schierholz JM, Lucas LJ, Rump A (1998) J Hosp Infect 40(4):25710.1016/S0195-6701(98)90301-2 ↗
17. Gollwitzer H, Meyer H, Stemberger A (2003) Trauma Berufskrankh 5:34710.1007/s10039-002-0695-7 ↗
18. Sreenivasan PK, Furgang D, Markowitz K et al (2008). Clin Oral Investig. doi: 10.1007/s00784-008-0227-310.1007/s00784-008-0227-3 ↗
19. Thian ES, Huang J, Vickers ME et al (2006) J Mater Sci 41:709. doi: 10.1007/s10853-006-6489-810.1007/s10853-006-6489-8 ↗
20. Heidenau F, Stenzel F, Schmidt H et al (2001) Biomaterialien 1:19
21. Heidenau F, Mittelmeier W, Detsch R et al (2005) J Mater Sci: Mater Med 16:883
22. Finke B, Lüthen F, Schröder K et al (2007) Biomaterials 28:452110.1016/j.biomaterials.2007.06.028 ↗
23. Becker P, Neumann HG, Nebe B et al (2004) J Mater Sci: Mater Med 15:437
24. Neumann HG, Baumann A, Wanke G et al (2002) Key Eng Mater 218–220:601
25. Haenle M, Heidenau F, Bader R et al (2007) Biomaterialien 8(2):88
26. Roessler S, Zimmermann R, Scharnweber D et al (2002) Colloid Surf B: Biointerf 26:38710.1016/S0927-7765(02)00025-5 ↗
27. Zimmermann E, Geiger B, Addadi L (2002) Biophys J 82:184810.1016/S0006-3495(02)75535-5 ↗
28. Cohen M, Kam Z, Addadi L et al (2006) EMBO J 25:30210.1038/sj.emboj.7600960 ↗
29. Cohen M, Klein E, Geiger B et al (2003) Biophys J 85:199610.1016/S0006-3495(03)74627-X ↗
30. Khan A, Kerfoot SM, Heit B et al (2004) J Immunol 173:759410.4049/jimmunol.173.12.7594 ↗
31. Bolton J, Hu X (2002) J Mater Sci: Mater Med 13(6):567
32. Fritsche A, Haenle M, Mittelmeier W et al (2008) Mat-wiss u Werkstofftech 39(9):65910.1002/mawe.200800325 ↗
33. ISO 20502 (2005) Fine ceramics (advanced ceramics, advanced technical ceramics)—Determination of adhesion of ceramic coatings by scratch testing
34. DIN EN 582 (1994) Ermittlung der Haftzugfestigkeit
35. Bader R, Steinhauser E, Holzwarth U et al (2004) Proc Inst Mech Eng [H] 218:22310.1243/0954411041561009 ↗
36. Bader R, Mittelmeier W, Steinhauser E et al (2005) Materialprüfung 47:2
37. Ruth M, Peritz E, Gabriel KR (1976) Biometrika 63–3:655
38. Oechsner H, Schafft M, Schumacher A et al (1998) Mat-wiss u Werkstofftech 29:46610.1002/mawe.19980290905 ↗
39. Rie KT, Gebauer A, Wöhle J et al (1994) Mat-wiss u Werkstofftech 25:43110.1002/mawe.19940251107 ↗
40. ASTM F 1147 (2005) Standard test method for tension testing of calcium phosphate and metallic coatings
41. Lenz R, Mittelmeier W, Hansmann D et al (2009) Response of human osteoblasts exposed to wear particles generated at the interface of total hip stems and bone cement. J Biomed Mater Res A 89:37010.1002/jbm.a.31996 ↗
42. Fritsche A, Lüthen F, Lembke U et al (2008) In: Abstracts book 17th annual meeting EORS 2008, Madrid, 147 pp