Electrochemical sensor based on multi-walled carbon nanotubes–boehmite nanoparticle composite modified electrode
Source abstract
Abstract
A sensitive electrochemical sensor was developed for the analysis of dobutamine (Dob) using a glassy carbon electrode modified with multi-walled carbon nanotubes–boehmite nanoparticle composite (BNP–MWNTs/GCE). Scanning electron microscopy was used for the characterization of synthesized BNPs and the morphology of BNP–MWNTs on the surface of GCE. Under the optimized experimental conditions, the BNP–MWNTs/GCE exhibited higher peak current than bare GCE due to synergetic effect of BNPs and MWCNTs on the electrochemical oxidation of Dob. The effect of various experimental parameters such as pH, scan rate, accumulation time on the voltammetric response of Dob was studied and optimized. A wide linear range from 0.005 to 1.0 µM with a low detection limit of 8.9 nM was found for voltammetric quantification of Dob. The prepared sensor exhibited the acceptable repeatability, high reproducibility along with good stability which makes it appropriate candidate for determination Dob in pharmaceutical preparations.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Analytical Chemistry and Sensors · Pharmacological Effects and Assays
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. Chandra U, Swamy BEK, Gilbert O, Shankar SS, Mahanthesha KR, Sherigara BS (2010) Electrocatalytic oxidation of dopamine at chemically modified carbon paste electrode with 2,4-dinitrophenyl hydrazine. Int J Electrochem Sci 5:1–910.1016/S1452-3981(23)15261-8 ↗
2. Rastogi PK, Ganesan V, Krishnamoorthi S (2012) Ion exchange voltammetry at permselective copolymer modified electrode and its application for the determination of catecholamines. J Electroanal Chem 676:13–1910.1016/j.jelechem.2012.04.027 ↗
3. Zhang Y (2004) Voltammetric behavior of dobutamine at poly(acridine orange) film modified electrode and its determination by adsorptive stripping voltammetry. Anal Lett 37:2031–204210.1081/AL-200026666 ↗
4. Shahrokhian S, Ghalkhani M, Kohansal R, Mohammadi R (2016) Biomimetic sensor for dobutamine employing nano-TiO2/nafion/carbon nanoparticles modified electrode. Electroanalysis 28:970–97810.1002/elan.201500605 ↗
5. Sasikala M, Tirupati B, Venkateshwarlu G (2015) Quantitative determination of drugs by using cerium (IV) and rhodamine B couple: a spectrophotometric study. Int J Pharm Sci Res 6:5179–5187
6. Asadiana E, Shahrokhian S, Irajizad A, Jokar E (2014) N-situ electro-polymerization of graphene nanoribbon/polyanilinecomposite film: application to sensitive electrochemical detection of dobutamine. Sens Actuators B 196:582–58810.1016/j.snb.2014.02.049 ↗
7. Rao KK, Reddy M (2001) Spectrophotometric determination of dobutamine hydrochloride in pharmaceutical formulations. Asian J Chem 13:1535–1538
8. El-Kommos ME (1983) Spectrophotometric method for the determination of dobutamine hydrochloride. Analyst 108:380–38510.1039/an9830800380 ↗
9. Roopa KP, Jayanna BK, Nagaraja P (2015) Spectrophotometric determination of dobutamine hydrochloride in pharmaceutical formulations. Int J Pharm Sci Rev Res 32(1):55–60
10. Sasikala M, Priyanka P, Kumar TV, Venkateshvarlu G (2016) Spectrophotometric estimation of drugs using N-bromo succinamide and indigo caramine couple. Orient J Chem 32:617–62510.13005/ojc/320170 ↗
11. Hardee GE, Lai JW (1983) Determination of dobutamine in plasma by liquid chromatography with electrochemical detection. Anal Lett 16:69–7510.1080/00032718308064462 ↗
12. Husseini H, Mitrovic V, Schlepper M (1993) Rapid and sensitive assay of dobutamine in plasma by high-performance liquid chromatography and electrochemical detection. J Chromatogr B Biomed Sci Appl 620:164–16810.1016/0378-4347(93)80066-D ↗
13. Yingxue Z, Funan C, Zhujun Z (2004) Chemiluminescence determination of dobutamine hydrochloride in human serum by high performance liquid chromatographic separation connected with ultrafiltration technology. Chin J Anal Chem 6:769–771
14. Thippani R, Pothuraju NR, Ramisetti NR, Shaik S (2013) Optimization and validation of a fast RP–HPLC method for the determination of dobutamine in rat plasma: pharmacokinetic studies in healthy rat subjects. J Pharm Anal 3:434–43910.1016/j.jpha.2013.07.003 ↗
15. Alberts G, Boomsma F, Schalekamp M (1992) Simultaneous determination of catecholamines and dobutamine in human plasma and urine by high-performance liquid chromatography with fluorimetric detection. J Chromatogr B Biomed Sci Appl 583:236–24010.1016/0378-4347(92)80558-8 ↗
16. Tian FS, Chen YH, Liang HY (2014) Determination of dobutamine hydrochloride by enzymatic catalytic spectrofluorimetry. Luminescence 29:92–9510.1002/bio.2509 ↗
17. Jin L, Jian-hua L, Gui-liang C (2006) Capillary gas chromatographic determination of organic residual in dobutamine hydrochloride using head-space injection and direct injection of solution. Chin J Pharm Anal 26:120–123
18. Keski-Hynnil H, Kurkela M, Elovaara E, Antonio L, Magdalou J, Luukkanen L, Taskinen J, Kostiainen R (2002) Comparison of electrospray, atmospheric pressure chemical ionization, and atmospheric pressure photoionization in the identification of apomorphine, dobutamine, and entacapone phase II metabolites in biological samples. Anal Chem 74:3449–345710.1021/ac011239g ↗
19. Wang Y (2011) Simultaneous determination of uric acid, xanthine and hypoxanthine at poly(pyrocatechol violet)/functionalized multi-walled carbon nanotubes composite film modified electrode. Colloids Surf B Biointerfaces 88:614–62110.1016/j.colsurfb.2011.07.051 ↗
20. Xiang D, Liu X, Dong X (2017) A facile synthetic method and electrochemical performances of nickel oxide/carbon fibers composites. J Mater Sci 52:7709–7718. doi: 10.1007/s10853-017-1019-410.1007/s10853-017-1019-4 ↗
21. Ghalkhani M, Shahrokhian S (2016) Development of a nanocellulose composite based voltammetric sensor for vitamin B9 analysis. Current Nanosci 12(4):493–49910.2174/1573413712666151202211216 ↗
22. Shahrokhian S, Balotf H, Ghalkhani M (2015) Nano composite coating based on cellulose nanofibers/carbon nanoparticles: application to voltammetric determination of clonazepam. J Solid State Electrochem 19:251–26010.1007/s10008-014-2597-6 ↗
23. Luo F, Ling Y, Zhang Q, Yu X, Liu Q, Yang Z (2017) Carbon paper-free membrane electrode assembly fabricated from a Pt electrocatalyst supported on multi-walled carbon nanotubes. J Mater Sci 52:8412–8420. doi: 10.1007/s10853-017-1081-y10.1007/s10853-017-1081-y ↗
24. Ghalkhani M, Beheshtian J, Salehi M (2016) Electrochemical and DFT study of an anticancer and active anthelmintic drug at carbon nanostructured modified electrode. Mater Sci Eng C 69:1345–135310.1016/j.msec.2016.08.031 ↗
25. Chernyshov DV, Shvedene NV, Antipova ER, Pletnev IV (2008) Ionic liquid-based miniature electrochemical sensors for the voltammetric determination of catecholamines. Anal Chim Acta 621:178–18410.1016/j.aca.2008.05.042 ↗
26. Ling Y, Huang Q, Feng D, Li X, Wei Y (2013) Electrochemical oxidation of dobutamine on a magnesium oxide micro flowers–nafion composite film modified glassy carbon electrode. Anal Methods 5:4580–458410.1039/c3ay40496j ↗
27. Lin X, Ni Y, Kokot S (2013) A novel electrochemical sensor for the analysis of β-agonists: the poly(acid chrome blue K)/graphene oxide-nafion/glassy carbon electrode. J Hazard Mater 260:508–51710.1016/j.jhazmat.2013.06.004 ↗
28. Bolzan AE, Piatti RCV, Arvia AJ (2003) Electrochemical processes at gold thiourea-containing aqueous acid solution interface. J Electroanal Chem 552:19–3410.1016/S0022-0728(03)00020-2 ↗
29. Kang J, Li Z, Lu X, Wang Y (2004) Studies on the electrochemical behavior of 3-nitrobenzaldehyde thiosemicarbazone at glassy carbon electrode modified with nano-Al2O3. Electrochim Acta 50:19–2610.1016/j.electacta.2004.07.008 ↗
30. Zhou W, Dai X, Fu T-M, Xie C, Liu J, Lieber CM (2014) Long term stability of nanowire nanoelectronics in physiological environments. Nano Lett 14:1614–161910.1021/nl500070h ↗
31. Gholivand MB, Malekzadeh G, Derakhshan AA (2014) Boehmite nanoparticle modified carbon paste electrode for determination of piroxicam. Sens Actuators B 201:378–38610.1016/j.snb.2014.04.054 ↗
32. Tok AIY, Boey FYC, Zhao XL (2006) Novel synthesis of Al2O3 nano-particles by flame spray pyrolysis. J Mater Process Technol 178:270–27310.1016/j.jmatprotec.2006.04.007 ↗
33. Jayaraman V, Prabhu E, Murthy ASR, Clinsha PC, Gnanasekar KI, Gnanasekaran T (2014) Na–β–Al2O3 based sensor for sodium aerosol. Sens Actuators B 202:9–1310.1016/j.snb.2014.05.053 ↗
34. Li J, Sun W, Wang X, Duan H, Wang Y, Sun Y, Ding C, Luo C (2016) Ultra-sensitive film sensor based on Al2O3–Au nanoparticles supported on PDDA-functionalized graphene for the determination of acetaminophen. Anal Bioanal Chem 408:5567–557610.1007/s00216-016-9654-1 ↗
35. Su YL, Tai CY, Zen JM (2013) A simple method to tune up screen-printed carbon electrodes applicable to the design of disposable electrochemical sensors. Electroanalysis 25:2539–254610.1002/elan.201300382 ↗
36. Marco JP, Borges KB, Tarley CRT, Ribeiro ES, Pereira AC (2013) Development and application of an electrochemical biosensor based on carbon paste and silica modified with niobium oxide, alumina and DNA (SiO2/Al2O3/Nb2O5/DNA) for amitriptyline determination. J Electroanal Chem 704:159–16810.1016/j.jelechem.2013.06.021 ↗
37. Habibi D, Faraji AR, Gil A (2013) A highly sensitive supported manganese-based voltammetric sensor for the electrocatalytic determination of captopril. Sens Actuators B 18:80–8610.1016/j.snb.2013.02.095 ↗
38. Xue ZH, Feng YJ, Guo HX, Hu CX, Mohmed AMI, Li JS, Lu XQ (2014) A novel electrocatalytic platform for separation of the overlapping voltammetric responses of AA, DA and UA. RSC Adv 4:5849–585210.1039/c3ra45677c ↗
39. Sun J-Y, Gan T, Deng Y-P, Shi Z-X, Lv Z (2015) Pt nanoparticles-functionalized hierarchically porous γ-Al2O3 hollow spheres based electrochemical sensor for ultrasensitive guaiacol detection. Sens Actuators B 211:339–34510.1016/j.snb.2015.01.104 ↗
40. Ulihin AS, Uvarov NF, Mateyshina YuG, Brezhneva LI, Matvienko AA (2006) Composite solid electrolytes LiClO4–Al2O3. Solid State Ion 177:2787–279010.1016/j.ssi.2006.03.018 ↗
41. Moss RE, Pérez-Roa RE, Anderson MA (2013) Electrochemical response of titania, zirconia, and alumina electrodes to phosphate adsorption. Electrochim Acta 104:314–32110.1016/j.electacta.2013.04.074 ↗
42. Bleam WF, Pfeffer PE, Goldberg S, Taylor RW, Dudley R (1991) A phosphorus-31 solid-state nuclear magnetic resonance study of phosphate adsorption at the boehmite/aqueous solution interface. Langmuir 7:1702–171210.1021/la00056a023 ↗
43. Rajabi L, Derakhshan AA (2010) Room Temperature synthesis of boehmite and crystallization of nanoparticles: effect of concentration and ultrasound. Sci Adv Mater 2:163–17210.1166/sam.2010.1063 ↗
44. Granados-Correa F, Jiménez-Becerril J (2009) Chromium (VI) adsorption on boehmite. J Hazard Mater 162:1178–118410.1016/j.jhazmat.2008.06.002 ↗