Electrochemical corrosion behaviors of titanium covered by various TiO2 nanotube films in artificial saliva
Source abstract
Abstract
TiO2 nanotube films obtained by anodization have shown great promise as biomaterials. In the present work, we report on the corrosion behaviors of titanium (Ti) with various TiO2 nanotubes prepared by using controlled anodization procedures. Special emphasis is put on the impact of film morphologies on the corrosion resistance of the Ti substrate. The corrosion behaviors of Ti with different nanotube films were studied in artificial saliva using open-circuit potential measurement, potentiodynamic polarization, and electrochemical impedance spectroscopy techniques. Ti covered by TiO2 nanotube films showed the markedly enhanced corrosion resistance properties compared to bare Ti. The existence of the compact oxide layer formed in a fluoride-free electrolyte was found to be beneficial for improving corrosion resistance properties. Besides, the TiO2 nanotube films obtained by two-step anodization had better corrosion resistance than those obtained by single-step anodization, though they used the identical anodization parameters.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Anodic Oxide Films and Nanostructures · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Noort RV (1987) Titanium: the implant material of today. J Mater Sci 22:3801–3811. https://doi.org/10.1007/BF011333210.1007/BF01133326 ↗
2. Hanawa T, Asami K, Asaoka K (1998) Repassivation of titanium and surface oxide film regenerated in simulated bioliquid. J Biomed Mat Res 40:530–53810.1002/(SICI)1097-4636(19980615)40:4<530::AID-JBM3>3.0.CO;2-G ↗
3. Cheng Y, Yang H, Yang Y, Huang J, Wu K, Chen Z, Wang X, Lin C, Lai Y (2018) Progress in TiO2 nanotube coatings for biomedical applications: a review. J Mater Chem B 6:1862–188610.1039/C8TB00149A ↗
4. Albrektsson T, Sennerby L (1990) Direct bone anchorage of oral implants: clinical and experimental considerations of the concept of osseointegration. Int J Prosthodont 3:30–41
5. Le GL, Soueidan A, Layrolle P, Amouriq Y (2007) Surface treatments of titanium dental implants for rapid osseointegration. Dent Mater 23:844–85410.1016/j.dental.2006.06.025 ↗
6. Demetrescu I, Pirvu C, Mitran V (2010) Effect of nano-topographical features of Ti/TiO2 electrode surface on cell response and electrochemical stability in artificial saliva. Bioelectrochemistry 79:122–12910.1016/j.bioelechem.2010.02.001 ↗
7. Hyeoung HP, Song P, Kyeong SK, Woo YJ, Byeung KP (2010) Bioactive and electrochemical characterization of TiO2 nanotubes on titanium via anodic oxidation. Electrochim Acta 55:6109–611410.1016/j.electacta.2010.05.082 ↗
8. Alves SA, Rossi AL, Ribeiro AR, Toptan F, Pinto AM, Shokuhfar T, Celis JP, Rocha LA (2018) Improved tribocorrosion performance of bio-functionalized TiO2 nanotubes under two-cycle sliding actions in artificial saliva. J Mech Behav Biomed Mater 80:143–15410.1016/j.jmbbm.2018.01.038 ↗
9. Alves SA, Patel SB, Sukotjo C, Mathew MT, Filho PN, Celis JP, Rocha LA, Shokuhfar T (2017) Synthesis of calcium-phosphorous doped TiO2 nanotubes by anodization and reverse polarization: a promising strategy for an efficient biofunctional implant surface. Appl Surf Sci 399:682–70110.1016/j.apsusc.2016.12.105 ↗
10. Alves SA, Rossi AL, Ribeiro AR, Toptan F, Pinto AM, Celis JP, Shokuhfar T, Rocha LA (2017) Tribo-electrochemical behavior of bio-functionalized TiO2 nanotubes in artificial saliva: understanding of degradation mechanisms. Wear 384–385:28–4210.1016/j.wear.2017.05.005 ↗
11. Lee K, Mazare A, Schmuki P (2014) One-dimensional titanium dioxide nanomaterials: nanotubes. Chem Rev 114:9385–945410.1021/cr500061m ↗
12. Park J, Bauer S, Schlegel KA, Neukam FW, Mark KVD, Schmuki P (2009) TiO2 nanotube surfaces: 15 nm—an optimal length scale of surface topography for cell adhesion and differentiation. Small 5:666–67110.1002/smll.200801476 ↗
13. Tan AW, Pingguan-Murphy B, Ahmad R, Akbar SA (2013) Advances in fabrication of TiO2 nanofiber/nanowire arrays toward the cellular response in biomedical implantations: a review. J Mater Sci 48:8337–8353. https://doi.org/10.1007/s10853-013-7659-010.1007/s10853-013-7659-0 ↗
14. Minagar S, Berndt CC, Wang J, Ivanova E, Wen C (2012) A review of the application of anodization for the fabrication of nanotubes on metal implant surfaces. Acta Biomater 8:2875–288810.1016/j.actbio.2012.04.005 ↗
15. Barao VA, Mathew MT, Assuncao WG, Yuan JC, Wimmer MA, Sukotjo C (2011) The role of lipopolysaccharide on the electrochemical behavior of titanium. J Dent Res 90:613–61810.1177/0022034510396880 ↗
16. Roy P, Berger S, Schmuki P (2011) TiO2 nanotubes: synthesis and applications. Angew Chem Int Ed 50:2904–293910.1002/anie.201001374 ↗
17. Yao C, Perla V, McKenzie JL, Slamovich EB, Webster TJ (2005) Anodized Ti and Ti6Al4V possessing nanometer surface features enhances osteoblast adhesion. J Biomed Nanotechnol 1:68–7310.1166/jbn.2005.008 ↗
18. Popat KC, Leoni L, Grimes CA, Desai TA (2007) Influence of engineered titania nanotubular surfaces on bone cells. Biomaterials 28:3188–319710.1016/j.biomaterials.2007.03.020 ↗
19. Tsuchiya H, Macak JM, Muller L, Kunze J, Muller F, Greil P, Virtanen S, Schmuki P (2006) Hydroxyapatite growth on anodic TiO2 nanotubes. J Biomed Mater Res A 77:534–54110.1002/jbm.a.30677 ↗
20. Wilmowsky CV, Baue S, Roedl S, Neukam FW, Schmuki P, Schlegel KA (2012) The diameter of anodic TiO2 nanotubes affects bone formation and correlates with the bone morphogenetic protein-2 expression in vivo. Clin Oral Impl Res 23:359–36610.1111/j.1600-0501.2010.02139.x ↗
21. Saji VS, Choe HC, Brantley WA (2009) An electrochemical study on self-ordered nanoporous and nanotubular oxide on Ti–35Nb–5Ta–7Zr alloy for biomedical applications. Acta Biomater 5:2303–231010.1016/j.actbio.2009.02.017 ↗
22. Yu WQ, Qiu J, Xu L, Zhang FQ (2009) Corrosion behaviors of TiO2 nanotube layers on titanium in Hank’s solution. Biomed Mater 4(6):06501210.1088/1748-6041/4/6/065012 ↗
23. Yu WQ, Qiu J, Zhang FQ (2011) In vitro corrosion study of different TiO2 nanotube layers on titanium in solution with serum proteins. Colloids Surf B 84:400–40510.1016/j.colsurfb.2011.01.033 ↗
24. Liu CL, Wang YJ, Wang M, Huang WJ, Chu PK (2012) Electrochemical behaviour of TiO2 nanotube on titanium in artificial saliva containing bovine serum albumin. Br Corros J 47:167–169
25. Indira K, Mudali UK, Rajendran N (2013) In-vitro biocompatibility and corrosion resistance of strontium incorporated TiO2 nanotube arrays for orthopaedic applications. J Biomater Appl 29:113–12910.1177/0885328213516821 ↗
26. Mazare A, Totea G, Burnei C, Schmuki P, Demetrescu I, Ionita D (2016) Corrosion, antibacterial activity and haemocompatibility of TiO2 nanotubes as a function of their annealing temperature. Corros Sci 103:215–22210.1016/j.corsci.2015.11.021 ↗
27. Cheng XL, Roscoe SG (2005) Corrosion behavior of titanium in the presence of calcium phosphate and serum proteins. Biomaterials 26:7350–735610.1016/j.biomaterials.2005.05.047 ↗
28. Richert L, Variola F, Rosei F, Wuest JD, Nanci A (2010) Adsorption of proteins on nanoporous Ti surfaces. Surf Sci 604:1445–145110.1016/j.susc.2010.05.007 ↗
29. Yu D, Zhu X, Xu Z, Zhong X, Gui Q, Song Y, Zhang S, Chen X, Li D (2014) Facile method to enhance the adhesion of TiO2 nanotube arrays to Ti substrate. ACS Appl Mater Interfaces 6:8001–800510.1021/am5015716 ↗
30. Man I, Pirvu C, Demetrescu I (2008) Enhancing titanium stability in Fusayama saliva using electrochemical elaboration of TiO2 nanotubes. Rev Chim 59:615–617
31. Tan AW, Pingguan-Murphy B, Ahmad R, Akbar SA (2012) Review of titania nanotubes: fabrication and cellular response. Ceram Int 38:4421–443510.1016/j.ceramint.2012.03.002 ↗
32. Karpagavalli R, Zhou A, Chellamuthu P, Nguyen K (2007) Corrosion behavior and biocompatibility of nanostructured TiO2 film on Ti6Al4V. J Biomed Mater Res Part A 83:1087–109510.1002/jbm.a.31447 ↗