journal article·2014-12

Degradation behavior of novel Fe/ß-TCP composites produced by powder injection molding for cortical bone replacement

Andreas Reindl, Rouven Borowsky, Sebastian Boris Hein, Juergen Geis-Gerstorfer, Philipp Imgrund, Frank Petzoldt

Journal of Materials Science· Volume 49· Issue 24
Publisher page

Abstract

When it comes to bone replacement in load-bearing areas, there are currently no adequate biodegradable implants available. Several non-degradable metallic materials fulfill the requirements of biocompatibility and mechanical strength. However, besides magnesium, only iron is a degradable metallic material. The aim of this long-term degradation study was to investigate the effects of iron beta-tricalcium phosphate interpenetrating phase composite on degradation rate and strength in comparison to pure iron. Cylindrical samples with 0–50 vol% beta-tricalcium phosphate (s-TCP) were prepared by powder injection molding. In addition to dense samples, porous iron samples with a porosity of 60.3 % were produced with polyoxymethylene as a placeholder. Dense and porous samples were immersed in 0.9 % sodium chloride solution (NaCl) or in phosphate buffered saline solution (PBS) for 56 days. Following immersion, the degradation rate, compressive yield strength, and ion release were determined. A maximum degradation rate of 196 µm/year was observed after 56 days for iron with 40 vol% s-TCP. This was found to be 28 % higher than for pure iron. After immersion, the compressive yield strength of pure iron decreased by 44 % (NaCl) and 48 % (PBS). In comparison, iron with 40 % s-TCP samples lost <1 % (NaCl) and 9 % (PBS) of strength following immersion. It was demonstrated that the solubility of calcium phosphate enhanced the corrosion processes and led to an increase in degradation, thus showing that the addition of s-TCP to pure iron can be a promising route for a novel degradable bone substitute material, particularly for load-bearing areas due to the increased strength.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding: laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 274:79–9610.1097/00003086-199201000-00010 ↗
2. Ridzwan MIZ, Shuib S, Hassan AY, Shokri AA, Mahamad Ibrahim MN (2007) Problem of stress shielding and improvement to the hip implant designs: a review. J Med Sci 7(3):460–46710.3923/jms.2007.460.467 ↗
3. Purnama A, Hermawan H, Champetier S, Mantovani D, Couet J (2013) Gene expression profile of mouse fibroblasts exposed to a biodegradable iron alloy for stents. Acta Biomater 9(10):8746–875310.1016/j.actbio.2013.02.033 ↗
4. Hermawan H, Purnama A, Dube D, Couet J, Mantovani D (2010) Fe–Mn alloys for metallic biodegradable stents: degradation and cell viability studies. Acta Biomater 6(5):1852–186010.1016/j.actbio.2009.11.025 ↗
5. Zhu S, Huang N, Xu L, Zhang Y, Liu H, Sun H, Leng Y (2009) Biocompatibility of pure iron: in vitro assessment of degradation kinetics and cytotoxicity on endothelial cells. Mater Sci Eng C 29(5):1589–159210.1016/j.msec.2008.12.019 ↗
6. Zhang E, Chen H, Shen F (2010) Biocorrosion properties and blood and cell compatibility of pure iron as a biodegradable biomaterial. J Mater Sci 21(7):2151–2163. doi: 10.1007/s10856-010-4070-0
7. Moravej M, Purnama A, Fiset M, Couet J, Mantovani D (2010) Electroformed pure iron as a new biomaterial for degradable stents: in vitro degradation and preliminary cell viability studies. Acta Biomater 6(5):1843–185110.1016/j.actbio.2010.01.008 ↗
8. Moravej M, Mantovani D (2011) Biodegradable metals for cardiovascular stent application: interests and new opportunities. Int J Mol Sci 12(7):4250–427010.3390/ijms12074250 ↗
9. Mueller PP, Arnold S, Badar M, Bormann D, Bach F, Drynda A, Meyer-Lindenberg A, Hauser H, Peuster M (2012) Histological and molecular evaluation of iron as degradable medical implant material in a murine animal model. J Biomed Mater Res Part A 100A:2881–288910.1002/jbm.a.34223 ↗
10. Peuster M, Hesse C, Schloo T, Fink C, Beerbaum P, von Schnakenburg C (2006) Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta. Biomaterials 27(28):4955–496210.1016/j.biomaterials.2006.05.029 ↗
11. Peuster M, Wohlsein P, Brügemann M, Ehlerding M, Seidler K, Fink C, Brauer H, Fischer A, Hausdorf G (2001) A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal—results 6–18 months after implantation into New Zealand white rabbits. Heart 86:563–56910.1136/heart.86.5.563 ↗
12. Waksman R, Pakala R, Baffour R, Seabron R, Hellinga D, Tio FO (2008) Short-Term Effects of Biocorrodible Iron Stents in Porcine Coronary Arteries. J Interv Cardiol 21(1):15–2010.1111/j.1540-8183.2007.00319.x ↗
13. Feng Q, Zhang D, Xin C, Liu X, Lin W, Zhang W, Chen S, Sun K (2013) Characterization and in vivo evaluation of a bio-corrodible nitrided iron stent. J Mater Sci Mater Med 24(3):713–724. doi: 10.1007/s10856-012-4823-z10.1007/s10856-012-4823-z ↗
14. Quadbeck P (10th–14th 2010) Iron based cellular metals for degradable synthetic bone replacement. Powder metallurgy world congress, Florence, Italy
15. Wegener B, Sievers B, Utzschneider S, Müller P, Jansson V, Rößler S, Nies B, Stephani G, Kieback B, Quadbeck P (2011) Microstructure, cytotoxicity and corrosion of powder-metallurgical iron alloys for biodegradable bone replacement materials. Mat Sci Eng B 176(20):1789–179610.1016/j.mseb.2011.04.017 ↗
16. Glorius S, Nies B, Farack J, Lode A, Quadbeck P, Hauser R, Standke G, Gelinsky M, Scharnweber D, Rößler S, Stephani G (2010) In: Fraunhofer IFAM D (ed) International conference on cellular materials, CellMat 2010, pp 219–224
17. Kraus T, Moszner F, Fischerauer S, Fiedler M, Martinelli E, Eichler J, Witte F, Willbold E, Schinhammer M, Meischel M, Uggowitzer PJ, Löffler JF, Weinberg A (2014) Biodegradable Fe-based alloys for use in osteosynthesis-outcome of an in vivo study after 52 weeks. Acta Biomater 10(7):3346–335310.1016/j.actbio.2014.04.007 ↗
18. Zheng YF, Gu XN, Witte F (2014) Biodegradable metals. Mat Sci Eng: R 77:1–3410.1016/j.mser.2014.01.001 ↗
19. Hermawan H, Moravej M, Dubé D, Fiset M, Mantovani D (2007) Degradation Behaviour of Metallic Biomaterials for Degradable Stents. Adv Mater 15–17:113–11810.4028/www.scientific.net/AMR.15-17.113 ↗
20. Deruyttere A, Froyen L, Bondt S (1989) Metal matrix composites. A bird’s eye view. Bull Mater Sci 12(3–4):217–22310.1007/BF02747133 ↗
21. Mathieu LM, Mueller TL, Bourban P, Pioletti DP, Müller R, Månson JE (2006) Architecture and properties of anisotropic polymer composite scaffolds for bone tissue engineering. Biomaterials 27(6):905–91610.1016/j.biomaterials.2005.07.015 ↗
22. Barrère F, Mahmood TA, de Groot K, van Blitterswijk CA (2008) Advanced biomaterials for skeletal tissue regeneration: instructive and smart functions. Mat Sci Eng: R 59(1–6):38–7110.1016/j.mser.2007.12.001 ↗
23. Jarcho M, Kay JF, Gumaer KI, Doremus RH, Drobeck HP (1977) Tissue, cellular and subcellular events at a bone-ceramic hydroxylapatite interface. J Bioeng 1(2):79–92
24. Klein CPAT, de Blieck-Hogervorst JMA, Wolke JGC, de Groot K (1990) Studies of the solubility of different calcium phosphate ceramic particles in vitro. Biomaterials 11(7):509–51210.1016/0142-9612(90)90067-Z ↗
25. LeGeros RZ (1993) Biodegradation and Bioresorption of Calcium Phosphate Ceramics. Clin Mater 14:65–8810.1016/0267-6605(93)90049-D ↗
26. Rezwan K, Chen QZ, Blaker JJ, Boccaccini AR (2006) Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering. Biomaterials 27(18):3413–343110.1016/j.biomaterials.2006.01.039 ↗
27. Klein CPAT, Driessen AA, de Groot K, van den Hooff A (1983) Biodegradation behavior of various calcium phosphate materials in bone tissue. J Biomed Mater Res Part A 17(5):769–78410.1002/jbm.820170505 ↗
28. Pilliar R, Filiaggi M, Wells J, Grynpas M, Kandel R (2001) Porous calcium polyphosphate scaffolds for bone substitute applications—in vitro characterization. Biomaterials 22:963–97210.1016/S0142-9612(00)00261-1 ↗
29. Suchanek W, Yoshimura M (1998) Processing and properties of hydroxyapatite-based biomaterials for use as hard tissue replacement implants. J Mater Res 13(1):94–11710.1557/JMR.1998.0015 ↗
30. Flautre B, Descamps M, Delecourt C, Blary MC, Hardouin P (2001) Porous HA ceramic for bone replacement: role of the pores and interconnections-experimental study in the rabbit. J Mater Sci 12:679–682. doi: 10.1023/A:1011256107282
31. Schinhammer M, Hofstetter J, Wegmann C, Moszner F, Löffler JF, Uggowitzer PJ (2013) On the immersion testing of degradable implant materials in simulated body fluid: active pH regulation using CO2. Adv Eng Mater 15(6):434–44110.1002/adem.201200218 ↗
32. German RM, Bose A (1997) Injection molding of metals and ceramics. Metal Powder Industries Federation, Princeton
33. He D, Ekere NN (2004) Effect of particle size ratio on the conducting percolation threshold of granular conductive–insulating composites. J Phys D 37(13):184810.1088/0022-3727/37/13/019 ↗
34. Periasamy C, Jhaver R, Tippur HV (2010) Quasi-static and dynamic compression response of a lightweight interpenetrating phase composite foam. Mat Sci Eng A 527(12):2845–285610.1016/j.msea.2010.01.066 ↗
35. ASTM (1972) Standard guide for laboratory immersion corrosion testing of metals, Philadelphia, PA, USA. Am Soc Test and Mater (G31). Accessed 2004
36. Dahme A (1953) Berechnung der spezifischen inneren Oberfläche poröser Körper. Ing Arch 21(5–6):346–35110.1007/BF00535857 ↗
37. Okazaki Y, Gotoh E (2005) Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26(1):11–2110.1016/j.biomaterials.2004.02.005 ↗
38. Xu L, Zhu S, Huang N, Li X, Zhang Y (2009) The corrosion of pure iron in five different mediums. J Biomed Eng 26(4):783–786
39. Fung Y (1993) Biomechanics: mechanical properties of living tissues, 2nd edn. Springer, New York10.1007/978-1-4757-2257-4 ↗
40. Geis-Gerstorfer J, Schille C, Schweizer E, Rupp F, Scheideler L, Reichel H, Hort N, Nolte A, Wendel H (2011) Blood triggered corrosion of magnesium alloys. 2nd Symposium on Biodegradable Metals 176(20):1761–176610.1016/j.mseb.2011.06.006 ↗