journal article·2000-12

Review Micromechanical testing of bone trabeculae - potentials and limitations

E. Lucchinetti, D. Thomann, G. Danuser

Journal of Materials Science· Volume 35· Issue 24
Publisher page

Abstract

The mechanical properties of bone are studied mostly for reasons related to skeletal pathology. However, bone is also very interesting from a material science perspective because it is a natural hierarchical composite material. The mechanical properties of bone depend on both the structural arrangement and the properties of the constituting materials, namely the organic polymer collagen and the inorganic salt apatite. While the mechanical properties of bone samples at the macroscopic scale are measured routinely, mechanical tests on micrometer-sized specimens are still at development stage. In this paper, protocols for measuring the elasticity of cancellous bone trabeculae are reviewed. The published values for the elastic modulus of trabeculae vary between 1 GPa and 15 GPa. Reasons for this broad range of values may be located in the intrinsic difficulties of preparing, handling, and testing inhomogeneous, anisotropic and asymmetric micro-samples. We discuss the major error sources in existing testing procedures and suggest potential strategies to enhance their performance.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone health and osteoporosis research · Cellular Mechanics and Interactions · Elasticity and Material Modeling

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. R. P. HEANEY, Calcif. Tissue Int. 53(Suppl 1) (1993) S3-6.10.1007/BF01673394 ↗
2. J. WOLFF, Das Gesetz der Transformation der Knochen August Hirschwald, Berlin, 1892.
3. G. H. BOURNE, “The Biochemistry and Physiology of Bone,” vol. 1 (Academic Press, New York and London, 1972).
4. A. P. SPENCE, “Basic Human Anatomy” (The Benjamin/Cummings Publishing Company, Inc., Redwood City, CA 94065, 1990).
5. V. CANE, G. MAROTTI, G. VOLPI, D. ZAFFE, S. PALAZZINI, F. REMAGGI and M. A. MUGLIA, Calcif. Tissue Int. 34 (1982) 558.10.1007/BF02411304 ↗
6. W. J. WHITEHOUSE, J. Microsc. 101 (1974) 153.10.1111/j.1365-2818.1974.tb03878.x ↗
7. T. P. HARRIGAN and R. W. MANN, J. Mater. Sci. 19 (1984) 761.10.1007/BF00540446 ↗
8. J. KRAGSTRUP, F. MELSEN and L. MOSEKILDE, Metab-Bone-Dis-Relat-Res. 4 (1983) 291.10.1016/S0221-8747(83)80002-2 ↗
9. F. LINDE, P. NORGAARD, I. HVID, A. ODGAARD and K. SOBALLE, J. Biomech. 24 (1991) 803.10.1016/0021-9290(91)90305-7 ↗
10. S. C. COWIN, “Bone Mechanics” (CRC Press, Boca Raton, Fla., 1989).
11. S. C. COWIN and M. M. MEHRABADI, J. Biomech. 22 (1989) 503.10.1016/0021-9290(89)90001-8 ↗
12. S. A. GOLDSTEIN, ibid. 20 (1987) 1055.10.1016/0021-9290(87)90023-6 ↗
13. T. P. HARRIGAN, J. MURALI, R. W. MANN and W. H. HARRIS, ibid. 21 (1988) 269.10.1016/0021-9290(88)90257-6 ↗
14. C. H. TURNER and S. C. COWIN, J. Biomech. Eng. 110 (1988) 213.10.1115/1.3108433 ↗
15. R. B. ASHMAN, J. D. CORIN and C. H. TURNER, J. Biomech. 20 (1987) 979.10.1016/0021-9290(87)90327-7 ↗
16. R. B. ASHMAN, S. C. COWIN, W. C. VAN BUSKIRK and J. C. RICE, ibid. 17 (1984) 349.10.1016/0021-9290(84)90029-0 ↗
17. B. VAN RIETBERGEN, H. WEINANS, R. HUISKES and A. ODGAARD, ibid. 28 (1995) 69.10.1016/0021-9290(95)80008-5 ↗
18. B. VAN RIETBERGEN, A. ODGAARD, J. KABEL and R. HUISKES, J. Orthop. Res. 16 (1998) 23.10.1002/jor.1100160105 ↗
19. J. KABEL, B. VAN RIETBERGEN, M. DALSTRA, A. ODGAARD and R. HUISKES, J. Biomech. 32 (1999) 673.10.1016/S0021-9290(99)00045-7 ↗
20. F. J. HOU, S. M. LANG, S. J. HOSHAW, D. A. REIMANN and D. P. FYHRIE, ibid. 31 (1998) 1009.10.1016/S0021-9290(98)00110-9 ↗
21. A. J. C. LADD, J. H. KINNEY, D. L. HAUPT and S. A. GOLDSTEIN, J. Orthop. Res. 16 (1998) 622.10.1002/jor.1100160516 ↗
22. C. R. JACOBS, B. R. DAVIS, C. J. RIEGER, J. J. FRANCIS, M. SAAD and D. P. FYHRIE, J. Biomech. 32 (1999) 1159.10.1016/S0021-9290(99)00115-3 ↗
23. J. W. PUGH, Bull. Hosp. Joint Dis. 34 (1973) 92.
24. J. C. RUNKLE and J. W. PUGH, ibid. 36 (1975) 2.
25. P. R. TOWNSEND, R. M. ROSE and E. L. RADIN, J. Biomech. 8 (1975) 199.10.1016/0021-9290(75)90025-1 ↗
26. P. L. MENTE and J. L. LEWIS, J. Orthop. Res. 7 (1989) 456.10.1002/jor.1100070320 ↗
27. S. D. RYAN and J. L. WILLIAMS, J. Biomech. 22 (1989) 351.10.1016/0021-9290(89)90049-3 ↗
28. J. L. KUHN, S. A. GOLDSTEIN, K. CHOI, M. LONDON, L. A. FELDKAMP and L. S. MATTHEWS, J. Orthop. Res. 7 (1989) 876.10.1002/jor.1100070614 ↗
29. K. CHOI, J. L. KUHN, M. J. CIARELLI and S. A. GOLDSTEIN, J. Biomech. 23 (1990) 1103.10.1016/0021-9290(90)90003-L ↗
30. J. C. RICE, S. C. COWIN and J. A. BOWMAN, ibid. 21 (1988) 155.10.1016/0021-9290(88)90008-5 ↗
31. R. B. ASHMAN and J. Y. RHO, ibid. 21 (1988) 177.10.1016/0021-9290(88)90167-4 ↗
32. J. Y. RHO, R. B. ASHMAN and C. H. TURNER, ibid. 26 (1993) 111.10.1016/0021-9290(93)90042-D ↗
33. A. ODGAARD, I. HVID and F. LINDE, ibid. 22 (1989) 829.10.1016/0021-9290(89)90066-3 ↗
34. A. ODGAARD and F. LINDE, ibid. 24 (1991) 691.10.1016/0021-9290(91)90333-I ↗
35. M. SALOME, F. PEYRIN, P. CLOETENS, C. ODET, A. M. LAVAL-JEANTET, J. BARUCHEL and P. SPANNE, Med. Phys. 26 (1999) 2194.10.1118/1.598736 ↗
36. D. B. BURR and M. HOOSER, Bone 17 (1995) 431.10.1016/S8756-3282(95)00241-3 ↗
37. G. DANUSER, P. T. TRAN and E. D. SALMON, J. Microsc. 198 (2000) 34.10.1111/j.1365-2818.2000.00678.x ↗
38. E. MAZZA, G. DANUSER and J. DUAL, Microsystem Technologies 2 (1996) 83.10.1007/s005420050021 ↗
39. G. DANUSER and E. MAZZA, In “Optical Inspection and Micromeasurements,” edited by C. Gorecki, vol. 2782 (European Optical Society, SPIE, 1996) p. 180.10.1117/12.250744 ↗
40. A. I. D. PRENTICE, Nature 206 (1965) 1167.10.1038/2061167a0 ↗
41. C. H. BACHMAN and E. H. ELLIS, ibid. 206 (1965) 1328.10.1038/2061328a0 ↗
42. A. I. D. PRENTICE, J. Clin. Path. 20 (1967) 717.10.1136/jcp.20.5.717 ↗
43. W. DENK, J. H. STRICKLER and W. W. WEBB, Science 248 (1990) 73.10.1126/science.2321027 ↗
44. T. FUNATSU, Y. HARADA, M. TOKUNAGA, K. SAITO and T. YANAGIDA, Nature 374 (1995) 555.10.1038/374555a0 ↗