Testing the accuracy of low-beam-energy electron-excited X-ray microanalysis with energy-dispersive spectrometry
Source abstract
Abstract
Abstract The accuracy of electron-excited X-ray microanalysis with energy-dispersive spectrometry (EDS) has been tested in the low beam energy range, specifically at an incident beam energy of 5 keV, which is the lowest beam energy for which a useful characteristic X-ray peak can be excited for all elements of the periodic table, excepting H and He. Elemental analysis results are reported for certified reference materials (CRM), stoichiometric compounds, minerals, and metal alloys of independently known or measured composition which had microscopic homogeneity suitable for microanalysis. Two-hundred sixty-three concentration measurements for 39 elements in 113 materials were determined following the k-ratio protocol and using the EDS analytical software NIST DTSA-II. The accuracy of the results, as characterized by the relative deviation from expected value (RDEV) metric, was such that more than 98% of the results were found to be captured within a range of ±5% RDEV, while 82% of the results fell in the range -2% to 2% RDEV.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · X-ray Spectroscopy and Fluorescence Analysis · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Goldstein JI, Newbury DE, Michael JR, Ritchie NWM, Scott JHJ, Joy DC (2018) Scanning Electron Microscopy and X-ray Microanalysis, 4th edn. Springer, New York10.1007/978-1-4939-6676-9 ↗
2. Newbury DE, Ritchie NWM (2016) Electron-Excited X-ray Microanalysis at Low Beam Energy: Almost Always an Adventure! Microsc Microanal 22:735–75310.1017/S1431927616011521 ↗
3. Ritchie, N.W. (2021) DTSA-II open access software for quantitative electron excited X-ray microanalysis with energy dispersive spectrometry; available for free, including tutorials, at the NIST website: https://www.nist.gov/services-resources/software/nist-dtsa-ii.
4. Ritchie NW, Newbury DE (2012) Uncertainty estimates for electron probe X-ray microanalysis measurements. Anal chem 84(22):9956–996210.1021/ac301843h ↗
5. Ritchie NW (2020) Embracing uncertainty: Modeling the standard uncertainty in electron probe microanalysis—Part I. Microsc Microanal 26(3):469–48310.1017/S1431927620001555 ↗
6. Ritchie NW (2021) Embracing Uncertainty: Modeling Uncertainty in EPMA—Part II. Microsc Microanal 27(1):74–8910.1017/S1431927620024691 ↗
7. Ritchie N, Filip V (2011) Semantics for high speed automated particle analysis by SEM/EDX. Microsc Microanal 17(S2):896–89710.1017/S1431927611005356 ↗
8. Pouchou JL, & Pichoir F (1991) In: Electron Probe Quantitation. Heinrich KFJ, Newbury D (Eds.). Plenum, New York
9. Chantler CT, Olsen K, Dragoset RA, Chang J, Kishore AR, Kotochigova SA, Zucker DS (2005) X-Ray Form Factor, Attenuation and Scattering Tables (version 2.1). [Online] Available: http://physics.nist.gov/ffast [22-Jul-2019]. National Institute of Standards and Technology, Gaithersburg, MD. Originally published as Chantler, C.T., J. Phys. Chem. Ref. Data 29(4), 597-1048 (2000)
10. and Chantler, C.T., J. Phys. Chem. Ref. Data 24, 71-643 (1995).10.1063/1.555974 ↗
11. Sabbatucci L, Salvat F (2016) Theory and calculation of the atomic photoeffect. Radiat Phys Chem 121:122–14010.1016/j.radphyschem.2015.10.021 ↗
12. Newbury DE, Ritchie NWM (2015) Review: performing elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy dispersive x-ray spectrometry (SEM/SDD-EDS). J Mater Sci 50:493–518. https://doi.org/10.1007/s10853-014-8685-210.1007/s10853-014-8685-2 ↗
13. Gopon P, Fournelle J, Sobol PE, Llovet X (2013) Low-voltage electron-probe microanalysis of Fe–Si compounds using soft X-rays. Microsc Microanal 19(6):1698–170810.1017/S1431927613012695 ↗
14. Llovet X, Pinard PT, Heikinheimo E, Louhenkilpi S, Richter S (2016) Electron probe microanalysis of Ni silicides using Ni-L X-ray lines. Microsc Microanal 22(6):1233–124310.1017/S1431927616011831 ↗
15. Newbury D, Ritchie N (2020) Quantitative electron-excited X-ray microanalysis with low energy L-peaks. Microsc Microanal 26(S2):44–4910.1017/S1431927620013215 ↗
16. Newbury DE, Ritchie NWM (2019) Using the EDS Clues: Peak Fitting Residual Spectrum and Analytical Total. Microsc Microanal 25(Suppl 2):446–44710.1017/S1431927619002964 ↗
17. Meisenkothen F, Wheeler R, Uchic MD, Kerns RD, Scheltens FJ (2009) Electron Channeling: A Problem for X-Ray Microanalysis in Materials Science. Microsc Microanal 15(2):83–9210.1017/S1431927609090242 ↗