journal article·2020-12

Characterization of weld seam surface and corrosion behavior of laser-beam-welded AISI 2205 duplex stainless steel in simulated body fluid

Ceyhun Köse

Journal of Materials Science· Volume 55· Issue 36
Publisher page

Abstract

In this study, AISI 2205 duplex stainless steel was joined with laser welding. Base material and laser-welded samples were kept in simulated body fluid (SBF) for 1, 3, 7, 14, 21, and 28 days. This research investigated microstructure, hydroxyapatite (HA) structure formed on surfaces, surface topography, and corrosion properties of samples which were kept in SBF. Characterization studies were performed by using microhardness, optical microscope, macroscope, SEM–EDS, XRD, and atomic force microscope. According to results, it was found out that HA accumulation was higher on base material surface when compared to weld seam surface, and also calcium-deficient carbonate HA structure with low crystallinity was observed on all surfaces. Very low corrosion rates due to very low weight losses were detected in all samples kept in SBF. The results showed us that heat input changes had an important effect on surface roughness values (Ra), apatite morphology on weld seam surfaces, and corrosion behaviors. Overall, it is considered that laser-welded duplex stainless steel can be used as an implant material depending on surface characterization and corrosion behaviors.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Additive Manufacturing Materials and Processes · Hydrogen embrittlement and corrosion behaviors in metals · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Balamurugan A, Rajeswari S, Balossier G, Rebelo AHS, Ferreira JMF (2008) Corrosion aspects of metallic implants: an overview. Mater Corros 59:855–869. https://doi.org/10.1002/maco.20080417310.1002/maco.200804173 ↗
2. Shih CC, Shih CM, Chou KY, Lin SJ, Su YY (2007) Stability of passivated 316L stainless steel oxide films for cardiovascular stents. J Biomed Mater Res A 80:861–873. https://doi.org/10.1002/jbm.a.3091510.1002/jbm.a.30915 ↗
3. Kuroda D, Hiromoto S, Hanawa T, Katada Y (2002) Corrosion behavior of nickel-free high nitrogen austenitic stainless steel in simulated biological environments. Mater Trans 43:3100–3104. https://doi.org/10.2320/matertrans.43.310010.2320/matertrans.43.3100 ↗
4. Köse C, Kaçar R (2016) In vitro bioactivity and corrosion properties of laser beam welded medical grade AISI 316L stainless steel in simulated body fluid. Int J Electrochem Sci 11:2762–2777. https://doi.org/10.20964/11040276210.20964/110402762 ↗
5. Sivakumar M, Mudali UK, Rajeswari S (1993) Compatibility of ferritic and duplex stainless steels as implant materials: in vitro corrosion performance. J Mater Sci 28:6081–6086. https://doi.org/10.1007/BF0036502510.1007/BF00365025 ↗
6. Wan P, Ren Y, Zhang B, Yang K (2012) Effect of nitrogen on biocorrosion behavior of high nitrogen nickel-free stainless steel in different simulated body fluids. Mater Sci Eng C 32:510–516. https://doi.org/10.1016/j.msec.2011.12.00210.1016/j.msec.2011.12.002 ↗
7. Balla VK, Das M, Bose S, Ram GD, Manna I (2013) Laser surface modification of 316L stainless steel with bioactive hydroxyapatite. Mater Sci Eng C 33:4594–4598. https://doi.org/10.1016/j.msec.2013.07.01510.1016/j.msec.2013.07.015 ↗
8. Manivasagam G, Dhinasekaran D, Rajamanickam A (2010) Biomedical implants: corrosion and its prevention: a review. Recent Pat Corros Sci 2:40–54. https://doi.org/10.2174/187761080100201004010.2174/1877610801002010040 ↗
9. Ballarre J, Manjubala I, Schreiner WH, Orellano JC, Fratzl P, Ceré S (2010) Improving the osteointegration and bone-implant interface by incorporation of bioactive particles in sol–gel coatings of stainless steel implants. Acta Biomater 6:1601–1609. https://doi.org/10.1016/j.actbio.2009.10.01510.1016/j.actbio.2009.10.015 ↗
10. Cheng T, Tsai W, Lee J (1990) Electrochemical and corrosion behaviour of duplex stainless steels in Hank’s solution. J Mater Sci 25:936–943. https://doi.org/10.1007/BF0337218210.1007/BF03372182 ↗
11. Köse C, Kaçar R, Zorba AP, Bağırova M, Abamor EŞ, Allahverdiyev AM (2018) Interactions between fibroblast cells and laser beam welded AISI 2205 duplex stainless steel. Mater Sci Medz 24:159–165. https://doi.org/10.5755/j01.ms.24.2.1800610.5755/j01.ms.24.2.18006 ↗
12. Gregorutti RW, Grau JE, Sives F, Elsner I (2015) Mechanical, electrochemical and magnetic behaviour of duplex stainless steel for biomedical applications. Mater Sci Technol 31:1818–1824. https://doi.org/10.1179/1743284715Y.000000001710.1179/1743284715Y.0000000017 ↗
13. Rosalbino F, Scavina G, Ubertalli G (2020) Electrochemical corrosion behavior of LDX 2101® duplex stainless steel in a fluoride-containing environment. Mater Corros 2020:1–8. https://doi.org/10.1002/maco.20201182610.1002/maco.202011826 ↗
14. Eliades T, Athanasiou AE (2002) In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility. Angle Orthod 72:222–237. https://doi.org/10.1043/0003-3219(2002)072%3c0222:IVAOOA%3e2.0.CO;210.1043/0003-3219(2002)072<0222:IVAOOA>2.0.CO;2 ↗
15. Kocijan A, Conradi M (2010) The corrosion behaviour of austenitic and duplex stainless steels in artificial body fluids. Mater Tehnol 44:21–24
16. Sathiyanarayanan Marikkannu C, Balasrinivasan P, Muthupandi V (2002) Corrosion behaviour of Ti6A14V and duplex stainless steel (UNS31803) in synthetic bio-Fluids. Anti-Corros Methods Mater 49:33–37. https://doi.org/10.1108/000355902104358410.1108/0003559021043584 ↗
17. Conradi M, Schön PM, Kocijan A, Jenko M, Vancso GJ (2011) Surface analysis of localized corrosion of austenitic 316L and duplex 2205 stainless steels in simulated body solutions. Mater Chem Phys 130(2011):708–713. https://doi.org/10.1016/j.matchemphys.2011.07.04910.1016/j.matchemphys.2011.07.049 ↗
18. Kocijan A, Conradi M, Schön PM (2012) Austenitic and duplex stainless steels in simulated physiological solution characterized by electrochemical and X-ray photoelectron spectroscopy studies. J Biomed Mater Res, Part B 100:799–807. https://doi.org/10.1002/jbm.b.3251310.1002/jbm.b.32513 ↗
19. Gurappa I (2002) Characterization of different materials for corrosion resistance under simulated body fluid conditions. Mater Charact 49:73–79. https://doi.org/10.1016/S1044-5803(02)00320-010.1016/S1044-5803(02)00320-0 ↗
20. Fan X, Chen J, Zou JP, Wan Q, Zhou ZC, Ruan JM (2009) Bone-like apatite formation on HA/316L stainless steel composite surface in simulated body fluid. Trans Nonferr Metals Soc 19:347–352. https://doi.org/10.1016/S1003-6326(08)60276-910.1016/S1003-6326(08)60276-9 ↗
21. Köse C, Kaçar R (2015) Effect of welding speed on the mechanical properties and microstructure of laser welded AISI 316L stainless steel. J Fac Eng Archit Gazi Univ 30:225–235. https://doi.org/10.17341/gummfd.4934410.17341/gummfd.49344 ↗
22. Köse C, Kaçar R (2014) Mechanical properties of laser welded 2205 duplex stainless steel. Mater Test 56:779–785. https://doi.org/10.3139/120.11063210.3139/120.110632 ↗
23. Köse C (2016) An investigation of the surface characterization of laser surface remelted and laser beam welded AISI 316L stainless steel. Int J Electrochem Sci 11:3542–3554. https://doi.org/10.20964/11043310.20964/110433 ↗
24. Khot Rahul S, Rao TV, Keskar A, Girish HN, Madhusudan P (2020) Investigation on the effect of power and velocity of laser beam welding on the butt weld joint on TRIP steel. J Laser Appl 32:012016. https://doi.org/10.2351/1.513315810.2351/1.5133158 ↗
25. Liang T, Wang L, Liu Y, Song X (2020) Role of script MC carbides on the tensile behavior of laser-welded fusion zone in DZ125L/IN718 joints at 650°C. J Mater Sci 55:13389–13397. https://doi.org/10.1007/s10853-020-04931-w10.1007/s10853-020-04931-w ↗
26. Kokubo T, Takadama H (2006) How useful is SBF in predicting in vivo bone bioactivity? Biomater 27:2907–2915. https://doi.org/10.1016/j.biomaterials.2006.01.01710.1016/j.biomaterials.2006.01.017 ↗
27. ASTM G1-03-E (1999) Standard practice for preparing, cleaning, and evaluation corrosion test specimens. American Society for Testing and Materials
28. Thangarasu V, Anand R (2019) Comparative evaluation of corrosion behavior of Aegle Marmelos Correa diesel, biodiesel, and their blends on aluminum and mild steel metals, Chapter 17. In: Azad AK, Rasul M (eds) Advanced biofuels. Woodhead Publishing, Cambridge, pp 443–47110.1016/B978-0-08-102791-2.00017-9 ↗
29. Zabula AV, Dey S, Robinson JR et al (2020) Screening of molecular lanthanide corrosion inhibitors by a high-throughput method. Corros Sci 165:108377. https://doi.org/10.1016/j.corsci.2019.10837710.1016/j.corsci.2019.108377 ↗
30. Haldhar R, Prasad D, Bhardwaj N (2020) Experimental and theoretical evaluation of acacia catechu extract as a natural, economical and effective corrosion inhibitor for mild steel in an acidic environment. J Bio Tribo Corros 6:76. https://doi.org/10.1007/s40735-020-00368-510.1007/s40735-020-00368-5 ↗
31. Cojocaru EM, Raducanu D, Alturaihi SS, Nocivin A, Coman G, Cojocaru VD (2020) Influence of isochronal treatments on microstructure and mechanical properties of solution treated UNS S32750 SDSS alloy specimens. J Mater Res Technol 4:7870–7879. https://doi.org/10.1016/j.jmrt.2020.05.05610.1016/j.jmrt.2020.05.056 ↗
32. Haghdadi N, Cizek P, Hodgson PD, He Y, Sun B, Jonas JJ, Rohrer GS, Beladi H (2020) New insights into the interface characteristics of a duplex stainless steel subjected to accelerated ferrite-to-austenite transformation. J Mater Sci 55:5322–5339. https://doi.org/10.1007/s10853-020-04358-310.1007/s10853-020-04358-3 ↗
33. Stango SAX, Karthick D, Swaroop S, Mudali UK, Vijayalakshmi U (2018) Development of hydroxyapatite coatings on laser textured 316 LSS and Ti-6Al-4V and its electrochemical behavior in SBF solution for orthopedic applications. Ceram Int 44:3149–3160. https://doi.org/10.1016/j.ceramint.2017.11.08310.1016/j.ceramint.2017.11.083 ↗
34. Oyane A, Wang X, Sogo Y, Ito A, Tsurushima H (2012) Calcium phosphate composite layers for surface-mediated gene transfer. Acta Biomater 8:2034–2046. https://doi.org/10.1016/j.actbio.2012.02.00310.1016/j.actbio.2012.02.003 ↗
35. Park JH, Lee DY, Oh KT, Lee YK, Kim KM, Kim KN (2006) Bioactivity of calcium phosphate coatings prepared by electrodeposition in a modified simulated body fluid. Mater Lett 60:2573–2577. https://doi.org/10.1016/j.matlet.2005.07.09110.1016/j.matlet.2005.07.091 ↗
36. Byrappa K, Ohachi T (2006) Crystal growth technology, Chapter 16 Growth of Hydroxyapatite Crystals. William Andrew Publishing, New York, pp 525–548
37. Köse C, Kaçar R, Zorba AP, Bağırova M, Allahverdiyev MA (2016) The Effect of CO2 laser beam welded AISI 316L austenitic stainless steel on the viability of fibroblast cells, in vitro. Mater Sci Eng C 60:211–218. https://doi.org/10.1016/j.msec.2015.11.03510.1016/j.msec.2015.11.035 ↗
38. Rubitschek F, Niendorf T, Karaman I, Maier HJ (2012) Corrosion fatigue behavior of a biocompatible ultrafine-grained niobium alloy in simulated body fluid. J Mech Behav Biomed Mater 5:181–192. https://doi.org/10.1016/j.jmbbm.2011.08.02310.1016/j.jmbbm.2011.08.023 ↗
39. Chew KK, Zein SHS, Ahmad AL (2012) The corrosion scenario in human body: stainless steel 316L orthopaedic implants. Nat Sci 4:184–188. https://doi.org/10.4236/ns.2012.4302710.4236/ns.2012.43027 ↗
40. Hansen DC (2008) Metal corrosion in the human body: the ultimate bio-corrosion scenario. Trans Electrochem Soc Interface 17:17–31
41. Hedberg YS, Wallinder IO (2016) Metal release from stainless steel in biological environments: a review. Biointerphases 11:018901. https://doi.org/10.1116/1.493462810.1116/1.4934628 ↗
42. Tabeshian A, Persson D, Arnberg L, Aune R (2019) Comparison of the electrochemical behavior of amorphous Zr55Cu30Ni5Al10, stainless steel (316LVM), and CoCrMo (F75) in simulated body fluid with and without addition of protein. Mater Corros 70:652–660. https://doi.org/10.1002/maco.20181048010.1002/maco.201810480 ↗
43. Li TT, Ling L, Lin MC, Peng HK, Ren HT, Lou CW, Lin JH (2020) Recent advances in multifunctional hydroxyapatite coating by electrochemical deposition. J Mater Sci 55:6352–6374. https://doi.org/10.1007/s10853-020-04467-z10.1007/s10853-020-04467-z ↗
44. Pulikkottil VJ, Chidambaram S, Bejoy PU, Femin PK, Paul Rishad M (2016) Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: an in vitro study. J Pharm Bioallied Sci 8:96–99. https://doi.org/10.4103/0975-7406.19203210.4103/0975-7406.192032 ↗
45. Kong D, Dong C, Ni X, Zhang L, Luo H, Li R, Wang L, Man C, Li X (2019) The passivity of selective laser melted 316L stainless steel. Appl Surf Sci 144:495–504. https://doi.org/10.1016/j.apsusc.2019.14449510.1016/j.apsusc.2019.144495 ↗
46. Han Z, He C, Lian J, Zhao Y, Chen X (2020) Effects of temperature on corrosion behaviour of 2205 duplex stainless steel in carbon dioxide-containing environments. Int J Electrochem Sci 15:3627–3645. https://doi.org/10.20964/2020.05.7310.20964/2020.05.73 ↗
47. Yang X, Shao J, Liu Z, Zhang D, Cui L, Du C, Li X (2020) Stress-assisted microbiologically influenced corrosion mechanism of 2205 duplex stainless steel caused by sulfate-reducing bacteria. Corros Sci 173:108746. https://doi.org/10.1016/j.corsci.2020.10874610.1016/j.corsci.2020.108746 ↗
48. Man C, Dong C, Liu T, Kong D, Wang D, Li X (2019) The enhancement of microstructure on the passive and pitting behaviors of selective laser melting 316L SS in simulated body fluid. Appl Surf Sci 467–468:193–205. https://doi.org/10.1016/j.apsusc.2018.10.15010.1016/j.apsusc.2018.10.150 ↗
49. Ralston KD, Birbilis N, Davies CHJ (2010) Revealing the relationship between grain size and corrosion rate of metals. Scripta Mater 63:1201–1204. https://doi.org/10.1016/j.scriptamat.2010.08.03510.1016/j.scriptamat.2010.08.035 ↗
50. Gupta RK, Prasad N, Rai AK, Biswal R, Sundar R, Bose A, Ganesh P, Ranganathan K, Bindra K, Kaul R (2018) Corrosion study on laser shock peened 316L stainless steel in simulated body fluid and chloride medium. Lasers Manuf Mater Process 5:270–282. https://doi.org/10.1007/s40516-018-0066-210.1007/s40516-018-0066-2 ↗
51. Köse C (2018) Investigation on microstructure, surface and corrosion characteristics of heat treated AISI 420 martensitic stainless steel laser welds in simulated body fluid (SBF). Int J Electrochem Sci 13(2018):12208–12225. https://doi.org/10.20964/2018.12.3010.20964/2018.12.30 ↗
52. Oshida Y, Tuna EB, Aktoren O, Gencay K (2010) Dental implant systems. Int J Mol Sci 11:1580–1678. https://doi.org/10.3390/ijms1104158010.3390/ijms11041580 ↗