Detection of cholesterol molecules with a liquid crystal-based pH-driven sensor
Source abstract
Abstract
Determining cholesterol levels is of great importance in the detection of high risk for heart disease. Here, we developed a real-time sensing strategy for free cholesterol molecules, employing ultraviolet (UV)-treated liquid crystals (LCs). When 4-cyano-4′-pentylbiphenyl (5CB), a nematic LC material, is treated with UV light, it shows a bright-to-dark optical response to a very small change in pH from 7.0 to 7.1, which can be observed with a polarizing optical microscopy at the aqueous/LC interface. In diagnostic applications, the second most widely used enzymatic reaction between cholesterol and cholesterol oxidase is able to generate H+, which could be detected by pH-sensitive LCs. Exploiting these mechanisms, a cholesterol sensor was designed and the device performed well in a range of cholesterol concentrations from 10 to 300 mg/mL, which covers the physiologically relevant range of cholesterol in the human body (90–220 mg/mL). We also determined the limit of detection, 1 × 10−9 mg/mL, and explored the effects of inhibitors on this sensor. The results obtained from this study may offer a simple tool for the detection of cholesterol compared with conventional methods and have potential for clinical diagnostics.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Receptor Mechanisms and Signaling · Lipid Membrane Structure and Behavior · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Rahman MM, X-B Li, Kim J, Lim BO, Ahammad AJS, Lee J-J (2014) A cholesterol biosensor based on a bi-enzyme immobilized on conducting poly(thionine) film. Sens Actuators B 202:536–54210.1016/j.snb.2014.05.114 ↗
2. Watanabe M, Yugawa K, Nankai S (2002) Cholesterol sensor and method of determining cholesterol. Google Patents. Patent No.: US 6342364 B1
3. Singh J, Kalita P, Singh MK, Malhotra B (2011) Nanostructured nickel oxide-chitosan film for application to cholesterol sensor. Appl Phys Lett 98(12):12370210.1063/1.3553765 ↗
4. Li G, Liao J, Hu G, Ma N, Wu P (2005) Study of carbon nanotube modified biosensor for monitoring total cholesterol in blood. Biosens Bioelectron 20(10):2140–214410.1016/j.bios.2004.09.005 ↗
5. Li Y, Bai H, Liu Q, Bao J, Han M, Dai Z (2010) A nonenzymatic cholesterol sensor constructed by using porous tubular silver nanoparticles. Biosens Bioelectron 25(10):2356–236010.1016/j.bios.2010.03.036 ↗
6. Chou LCS, Liu C-C (2005) Development of a molecular imprinting thick film electrochemical sensor for cholesterol detection. Sens Actuators B 110(2):204–20810.1016/j.snb.2005.01.031 ↗
7. Dong S, Deng Q, Cheng G (1993) Cholesterol sensor based on electrodeposition of catalytic palladium particles. Anal Chim Acta 279(2):235–24010.1016/0003-2670(93)80322-C ↗
8. Malhotra BD, Kaushik A (2009) Metal oxide–chitosan based nanocomposite for cholesterol biosensor. Thin Solid Films 518(2):614–62010.1016/j.tsf.2009.07.036 ↗
9. Giri AK, Charan C, Saha A, Shahi VK, Panda AB (2014) An amperometric cholesterol biosensor with excellent sensitivity and limit of detection based on an enzyme-immobilized microtubular ZnO@ZnS heterostructure. J Mater Chem A 2(40):16997–1700410.1039/C4TA03627A ↗
10. Dey RS, Raj CR (2014) Enzyme-integrated cholesterol biosensing scaffold based on in situ synthesized reduced graphene oxide and dendritic Pd nanostructure. Biosens Bioelectron 62:357–36410.1016/j.bios.2014.06.063 ↗
11. Nankai S, Yamamoto T, Yoshioka T (2000) Cholesterol sensor. Google Patents. Patent No.: US 6214612 B1
12. Sekretaryova AN, Beni V, Eriksson M, Karyakin AA, Turner AP, Vagin MY (2014) Cholesterol self-powered biosensor. Anal Chem 86(19):9540–954710.1021/ac501699p ↗
13. Vidal JC, Espuelas J, Garcia-Ruiz E, Castillo JR (2004) Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped with self-assembled monolayers. Talanta 64(3):655–66410.1016/j.talanta.2004.03.038 ↗
14. Brake JM, Abbott NL (2002) An experimental system for imaging the reversible adsorption of amphiphiles at aqueous-liquid crystal. Langmuir 18:6101–610910.1021/la011746t ↗
15. Zhang M, Jang CH (2014) Liquid crystal-based detection of thrombin coupled to interactions between a polyelectrolyte and a phospholipid monolayer. Anal Biochem 455:13–1910.1016/j.ab.2014.03.018 ↗
16. Zhang M, Jang CH (2013) Liquid crystal based optical sensor for imaging trypsin activity at interfaces between aqueous phases and thermotropic liquid crystals. Bull Korean Chem Soc 34(10):2973–297710.5012/bkcs.2013.34.10.2973 ↗
17. Hu Q, Jang CH (2010) Liquid crystal-based imaging of enzymatic reactions at aqueous-liquid crystal interfaces decorated with oligopeptide amphiphiles. Bull Korean Chem Soc 31(5):1262–126610.5012/bkcs.2010.31.5.1262 ↗
18. Liu D, Hu QZ, Jang CH (2013) Orientational behaviors of liquid crystals coupled to chitosan-disrupted phospholipid membranes at the aqueous-liquid crystal interface. Colloids Surf B 108:142–14610.1016/j.colsurfb.2013.02.047 ↗
19. Bi X, Hartono D, Yang K-L (2009) Real-time liquid crystal pH sensor for monitoring enzymatic activities of penicillinase. Adv Funct Mater 19(23):3760–376510.1002/adfm.200900823 ↗
20. Zhong S, Jang CH (2014) Highly sensitive and selective glucose sensor based on ultraviolet-treated nematic liquid crystals. Biosens Bioelectron 59:293–29910.1016/j.bios.2014.03.070 ↗
21. Tyagi M, Chandran A, Joshi T, Prakash J, Agrawal VV, Biradar AM (2014) Self assembled monolayer based liquid crystal biosensor for free cholesterol detection. Appl Phys Lett 104(15):15410410.1063/1.4871704 ↗
22. Park JS, Jang CH, Tingey ML, Lowe AM, Abbott NL (2006) Influence of 4-cyano-4′-biphenylcarboxylic acid on the orientational ordering of cyanobiphenyl liquid crystals at chemically functionalized surfaces. J Colloid Interface Sci 304(2):459–47310.1016/j.jcis.2006.08.063 ↗
23. Hartono D, Lai SL, Yang KL, Yung LY (2009) A liquid crystal-based sensor for real-time and label-free identification of phospholipase-like toxins and their inhibitors. Biosens Bioelectron 24(7):2289–229310.1016/j.bios.2008.11.021 ↗
24. Carlton RJ, Ma CD, Gupta JK, Abbott NL (2012) Influence of specific anions on the orientational ordering of thermotropic liquid crystals at aqueous interfaces. Langmuir 28(35):12796–1280510.1021/la3024293 ↗
25. Hu QZ, Jang CH (2011) Orientational behaviour of ultraviolet-tailored 4-cyano-4′-pentylbiphenyl at the aqueous/liquid crystal interface. Liq Cryst 38(9):1209–121610.1080/02678292.2011.603439 ↗
26. Hartono D, Hody Yang KL, Yung LY (2010) The effect of cholesterol on protein-coated gold nanoparticle binding to liquid crystal-supported models of cell membranes. Biomaterials 31(11):3008–301510.1016/j.biomaterials.2010.01.003 ↗
27. BRENDA (2014) Information on EC 1.1.3.6—cholesterol oxidase. http://brenda-enzymes.info/enzyme.php?ecno=1.1.3.6