journal article·2015-02Open access

Examining microstructural evolution of Portland cements by in-situ synchrotron micro-tomography

Matteo Parisatto, Maria Chiara Dalconi, Luca Valentini, Gilberto Artioli, Alexander Rack, Rémi Tucoulou, Giuseppe Cruciani, Giorgio Ferrari

Journal of Materials Science· Volume 50· Issue 4

Abstract

The application of synchrotron radiation X-ray computed micro-tomography (SR X-μCT) as a non-invasive approach to the microstructural investigation of Portland cement binders during hydration is presented. The two- and three-dimensional µm-scale imaging of undisturbed samples at hydration ages from ~1.5 h to 3 days is used to obtain a direct visualization of the spatial and temporal relationships between different cement paste components. The microstructural evolution of two cementitious systems during the early stages of hydration is successfully monitored from the comparison of tomographic slices and volumes, clearly showing the progressive growth of hydration phases; the changes in the amount of porosity and unreacted clinker are also quantified. Some critical issues related to the experimental setup and data processing are addressed and discussed as well. Furthermore, a simple procedure to estimate the mean X-ray absorption coefficient of cement pastes from X-ray radiographs is illustrated. The results confirm the potentialities of synchrotron-based X-ray computed micro-tomography for the three-dimensional investigation of µm-scale modifications in hydrating cement pastes with an adequate time resolution, thus providing a real in-situ monitoring of the microstructural evolution of such complex materials.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Drilling and Well Engineering · Concrete and Cement Materials Research · Mineral Processing and Grinding

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Scrivener KL (2004) Backscattered electron imaging of cementitious microstructures: understanding and quantification. Cem Concr Compos 26(8):935–94510.1016/j.cemconcomp.2004.02.029 ↗
2. Stutzman P (2004) Scanning electron microscopy imaging of hydraulic cement microstructure. Cem Concr Compos 26(8):957–96610.1016/j.cemconcomp.2004.02.043 ↗
3. Walsh D, Otooni MA, Taylor ME Jr, Marcinkowski MJ (1974) Study of Portland cement fracture surfaces by scanning electron microscopy techniques. J Mater Sci 9:423–429. doi: 10.1007/BF0073784210.1007/BF00737842 ↗
4. Kak AC, Slaney M (1988) Principles of computerized tomographic imaging. IEEE Press, New York
5. Bentz DP, Quenard DA, Kunzel HM, Baruchel J, Peyrin F, Martys NS, Garboczi EJ (2000) Microstructure and transport properties of porous building materials. II: three-dimensional X-ray tomographic studies. Mater Struct 33:147–15310.1007/BF02479408 ↗
6. Landis EN, Petrell AL, Lu S, Nagy EN (2000) Examination of pore structure using three-dimensional image analysis of microtomographic data. Concr Sci Eng 2:162–169
7. Bentz DP, Mizell S, Satterfield S, Devaney J, George W, Ketcham P, Graham J, Porterfield J, Quenard D, Vallee F, Sallee H, Boller E, Baruchel J (2002) The visible cement data set. J Res Natl Inst Stand Technol 107:137–14810.6028/jres.107.013 ↗
8. Helfen L, Dehn F, Mikulík P, Baumbach T (2005) Three-dimensional imaging of cement microstructure evolution during hydration. Adv Cem Res 17(3):103–11110.1680/adcr.2005.17.3.103 ↗
9. Burlion N, Bernard D, Chen D (2006) X-ray microtomography: application to microstructure analysis of a cementitious material during leaching process. Cem Concr Res 36:346–35710.1016/j.cemconres.2005.04.008 ↗
10. Gallucci E, Scrivener K, Groso A, Stampanoni M, Margaritondo G (2007) 3D experimental investigation of the microstructure of cements pastes using synchrotron X-ray microtomography (μCT). Cem Concr Res 37:360–36810.1016/j.cemconres.2006.10.012 ↗
11. Promentilla MAB, Sugiyama T, Hitomi T, Takeda N (2009) Quantification of tortuosity in hardened cement pastes using synchrotron-based X-ray computed microtomography. Cem Concr Res 39(6):548–55710.1016/j.cemconres.2009.03.005 ↗
12. Gastaldi D, Canonico F, Capelli L, Boccaleri E, Milanesio M, Palin L, Croce G, Marone F, Mader K, Stampanoni M (2012) In situ tomographic investigation on the early hydration behaviors of cementing systems. Constr Build Mat 29:284–29010.1016/j.conbuildmat.2011.10.016 ↗
13. Stock SR, De Carlo F, Almer JD (2008) High energy X-ray scattering tomography applied to bone. J Struct Biol 161:144–15010.1016/j.jsb.2007.10.001 ↗
14. Bleuet P, Welcomme E, Dooryhée E, Susini J, Hodeau J-L, Walter P (2008) Probing the structure of heterogeneous diluted materials by diffraction tomography. Nat Mater 7:468–47210.1038/nmat2168 ↗
15. Artioli G, Cerulli T, Cruciani G, Dalconi MC, Ferrari G, Parisatto M, Rack A, Tucoulou R (2010) X-ray diffraction microtomography (XRD-CT), a novel tool for non-invasive mapping of phase development in cement materials. Anal Bioanal Chem 397(6):2131–213610.1007/s00216-010-3649-0 ↗
16. Valentini L, Dalconi MC, Parisatto M, Cruciani G, Artioli G (2011) Towards three-dimensional quantitative reconstruction of cement microstructure by X-ray diffraction microtomography. J Appl Crystallogr 44(2):272–28010.1107/S0021889810054701 ↗
17. Voltolini M, Dalconi MC, Artioli G, Parisatto M, Valentini L, Russo V, Bonnin A, Tucoulou R (2013) Understanding cement hydration at the microscale: new opportunities from ‘pencil-beam’ synchrotron X-ray diffraction tomography. J Appl Crystallogr 46(1):142–15210.1107/S0021889812046985 ↗
18. Kantro DL (1980) Influence of water-reducing admixtures on properties of cement paste—a miniature slump test. Cem Concr Aggreg 2:95–10210.1520/CCA10190J ↗
19. Martinez-Criado G, Tucoulou R, Cloetens P, Bleuet P, Bohic S, Cauzid J, Kieffer I, Kosior E, Laboure S, Petitgirard S, Rack A, Angel Sans J, Segura-Ruiz J, Suhonen H, Susini J, Villanova J (2012) Status of the hard X-ray microprobe beamline ID22 of the European Synchrotron Radiation Facility. J Synchrotron Radiat 19(1):10–1810.1107/S090904951104249X ↗
20. Jennings RJ (1988) A method for comparing beam-hardening filter materials for diagnostic radiology. Med Phys 15:588–59910.1118/1.596210 ↗
21. Haibel A (2008) Synchrotron X-ray absorption tomography. In: Banhart J (ed) Advanced tomographic methods in materials research and engineering. Oxford University Press, New York, pp 141–16010.1093/acprof:oso/9780199213245.003.0005 ↗
22. Brooks RA, Di Chiro G (1976) Beam hardening in X-ray reconstructive tomography. Phys Med Biol 21:390–39810.1088/0031-9155/21/3/004 ↗
23. Snigirev A, Snigireva I, Kohn V, Kuznetsov S, Schelokov I (1995) On the possibilities of X-ray phase contrast microimaging by coherent high-energy synchrotron radiation. Rev Sci Instrum 66:5486–549210.1063/1.1146073 ↗
24. Raven C, Snigirev A, Snigireva I, Spanne P, Souvorov A, Kohn V (1996) Phase-contrast microtomography with coherent high-energy synchrotron X-rays. Appl Phys Lett 69:1826–182810.1063/1.117446 ↗
25. Cloetens P, Ludwig W, Baruchel J, Guigay J-P, Rejmankova-Pernot P, Salomé-Pateyron M, Schlenker M, Buffière JY, Maire E, Peix G (1999) Hard X-ray phase imaging using simple propagation of a coherent synchrotron radiation beam. J Phys D 32:A145–A15110.1088/0022-3727/32/10A/330 ↗
26. Labiche J-C, Mathon O, Pascarelli S, Newton MA, Guilera Ferre G, Curfs C, Vaughan G, Homs A, Fernandez Carreiras D (2007) The fast readout low noise camera as a versatile x-ray detector for time resolved dispersive extended X-ray absorption fine structure and diffraction studies of dynamic problems in materials science, chemistry, and catalysis. Rev Sci Instrum 78:09130110.1063/1.2783112 ↗
27. Koch A, Peyrin F, Heurtier P, Ferrand B, Chambaz B, Ludwig W, Couchaud M (1999) X-ray camera for computed microtomography of biological samples with micrometer resolution using Lu3Al5O12 and Y3Al5O12 scintillators. SPIE Conference on Physics of Medical Imaging, San Diego 3659:170–179
28. Mirone A, Wilcke R, Hammersley A, Ferrero C (2012) PyHST (High Speed Tomographic Reconstruction), http://www.esrf.eu/UsersAndScience/Experiments/TBS/SciSoft/
29. Mirone A, Brun E, Gouillart E, Tafforeau P, Kieffer J (2014) The PyHST2 hybrid distributed code for high speed tomographic reconstruction with iterative reconstruction and a priori knowledge capabilities. Nucl Instr Meth Phys Res B 324:41–4810.1016/j.nimb.2013.09.030 ↗
30. Henke BL, Gullikson EM, Davis JC (1993) X-ray interactions: photoabsorption, scattering, transmission, and reflection at E = 50-30000 eV, Z = 1-92, At Data Nucl Data Tables 54(2):181–342 ( http://henke.lbl.gov/optical_constants/ )10.1006/adnd.1993.1013 ↗
31. Bentz DP, Coveney PV, Garboczi EJ, Kleyn MF, Stutzman PE (1994) Cellular automaton simulations of cement hydration and microstructure development. Model Simul Mater Sci Eng 2:783–80810.1088/0965-0393/2/4/001 ↗
32. Cloetens P, Ludwig W, Baruchel J, Van Dyck D, Van Landuyt J, Guigay J-P, Schlenker M (1999) Holotomography: quantitative phase tomography with micrometer resolution using hard synchrotron radiation X-rays. Appl Phys Lett 75:2912–291410.1063/1.125225 ↗
33. Weitkamp T, Haas D, Wegrzynek D, Rack A (2011) ANKAphase: software for single-distance phase-retrieval from inline X-ray phase contrast radiographs. J Synchrotron Radiat 18:617–62910.1107/S0909049511002895 ↗
34. Langer M, Cloetens P, Guigay J-P, Peyrin F (2008) Quantitative comparison of direct phase retrieval algorithms in in-line phase tomography. Med Phys 35(10):4556–456610.1118/1.2975224 ↗
35. Zabler S, Riesemeier H, Fratzl P, Zaslansky P (2006) Fresnel-propagated imaging for the study of human tooth dentin by partially coherent X-ray tomography. Opt Expr 14(19):8584–859710.1364/OE.14.008584 ↗
36. Hubbell JH, Seltzer SM (1996) Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest, http://www.nist.gov/pml/data/xraycoef/index.cfm10.6028/NIST.IR.5632 ↗
37. Rack A, Garcia-Moreno F, Schmitt C, Betz O, Cecilia A, Ershov A, Rack T, Banhart J, Zabler S (2010) On the possibilities of hard X-ray imaging with high spatio-temporal resolution using polychromatic synchrotron radiation. J X-ray Sci Technol 18(4):429–44110.3233/XST-2010-0273 ↗