Bioactive glass coatings fabricated by laser cladding on ceramic acetabular cups: a proof-of-concept study
Source abstract
Abstract
Deposition of bioceramic coatings on medical implants is a valuable strategy to impart key added values, such as bioactivity. While flat coatings can be easily produced by enameling and similar techniques, applying a bioactive glass layer on surfaces with curved geometry is a great challenge from a technological viewpoint. In this work, for the first time we demonstrated the feasibility of bioactive glass coatings produced by laser cladding on alumina/zirconia ceramic acetabular cups for hip joint prosthesis. Laser-cladded glass coatings can be fabricated in a dense (pore-free) or porous form. Morphological analyses by scanning electron microscopy and micro-computed tomography revealed the good quality of joining at the coating/substrate interface and the good interconnectivity of the pores (size within 200–400 µm) in the outer porous layer. Indentation tests at the interface confirmed the excellent joining between glass and ceramic substrate. These coatings also exhibited a good bioactive behavior in vitro, as demonstrated by the formation of a surface apatite layer upon immersion studies in simulated body fluid.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. Lin X, De Groot K, Wang D, Hu Q, Wismeijer D, Liu Y (2015) A review paper on biomimetic calcium phosphate coatings. Open Biomed Eng J 9:56–6410.2174/1874120701509010056 ↗
2. Dorozhkin SV (2014) Calcium orthophosphate coatings on magnesium and its biodegradable alloys. Acta Biomater 10:2919–293410.1016/j.actbio.2014.02.026 ↗
3. Heimann RB (2013) Structure, properties, and biomedical performance of osteoconductive bioceramic coatings. Surf Coat Technol 233:27–3810.1016/j.surfcoat.2012.11.013 ↗
4. Taeger G, Podleska LE, Schmidt B, Ziegler M, Nast-Kolb D (2003) Comparison of diamond-like-carbon and alumina- oxide articulating with polyethylene in total hip arthroplasty. Materwiss Werksttech 34:1094–110010.1002/mawe.200300717 ↗
5. Huang SJ, Ju WS, Lyu SR (2006) A wear study of diamond-like carbon film for total hip arthroplasty applications. J Med Biol Eng 26:169–175
6. Olofsson J, Grehk TM, Berlind T, Persson C, Jacobson S, Engqvist H (2012) Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement. Biomatter 2:94–10210.4161/biom.20710 ↗
7. Pettersson M, Tkachenko S, Schmidt S, Berlind T, Jacobson S, Hultman L, Engqvist H, Persson C (2013) Mechanical and tribological behavior of silicon nitride and silicon carbon nitride coatings for total joint replacements. J Mech Behav Biomed Mater 25:41–4710.1016/j.jmbbm.2013.05.002 ↗
8. Mukherjee S, Maitz MF, Pham MT, Richter E, Prokert F, Moeller W (2005) Development and biocompatibility of hard Ti-based coatings using plasma immersion ion implantation-assisted deposition. Surf Coat Technol 196:312–31610.1016/j.surfcoat.2004.08.202 ↗
9. Serro AP, Completo C, Colaco R, Dos Santos F, Da Silva CL, Cabral JMS, Araujo H, Pires E, Saramago B (2009) A comparative study of titanium nitrides, TiN, TiNbN and TiCN, as coatings for biomedical applications. Surf Coat Technol 203:3701–370710.1016/j.surfcoat.2009.06.010 ↗
10. Kertzman Z, Marchal J, Suarez M, Staia M, Filip P, Kohli P, Aouadi S (2005) Mechanical, tribological, and biocompatibility properties of ZrN-Ag nanocomposite films. J Biomed Mater Res A 84:1061–1067
11. Chen CZ, Meng XG, Yu HJ, Yang H, He T, Wang DG, Zhao SG (2014) A review of coating preparing techniques of bioactive glass. Adv Mater Res 833:202–20710.4028/www.scientific.net/AMR.833.202 ↗
12. McEntire BJ, Bal BS, Rahaman MN, Chevalier J, Pezzotti G (2015) Ceramics and ceramic coatings in orthopaedics. J Eur Ceram Soc 35:4327–436910.1016/j.jeurceramsoc.2015.07.034 ↗
13. Hench LL (1988) Bioactive ceramics. Ann NY Acad Sci 523:54–7110.1111/j.1749-6632.1988.tb38500.x ↗
14. Baino F, Novajra G, Miguez-Pacheco V, Boccaccini AR, Vitale-Brovarone C (2016) Bioactive glasses: special applications outside the skeletal system. J Non-Cryst Solids 432:15–3010.1016/j.jnoncrysol.2015.02.015 ↗
15. Hench LL, Splinter RJ, Allen WC, Greenlee TK (1971) Bonding mechanisms at the interface of ceramic prosthetic materials. J Biomed Mater Res 5:117–14110.1002/jbm.820050611 ↗
16. Sun L, Berndt CC, Gross KA, Kucuk A (2001) Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: a review. J Biomed Mater Res (Appl Biomater) 58:570–59210.1002/jbm.1056 ↗
17. Sola A, Bellucci D, Cannillo V, Cattini A (2011) Bioactive glass coatings: a review. Surf Eng 27:560–57210.1179/1743294410Y.0000000008 ↗
18. Baino F, Marshall M, Kirk N, Vitale-Brovarone C (2016) Design, selection and characterization of novel glasses and glass-ceramics for use in prosthetic applications. Ceram Int 42:1482–149110.1016/j.ceramint.2015.09.094 ↗
19. Gomez-Vega JM, Saiz E, Tomsia AP, Oku T, Suganuma K, Marshall GW, Marchall SJ (2000) Novel bioactive functionally graded coatings on Ti6Al4V. Adv Mater 12:894–89810.1002/1521-4095(200006)12:12<894::AID-ADMA894>3.0.CO;2-4 ↗
20. Lopez-Esteban S, Saiz E, Fujino S, Oku T, Suganuma K, Tomsia AP (2003) Bioactive glass coatings for orthopedic metallic implants. J Eur Ceram Soc 23:2921–293010.1016/S0955-2219(03)00303-0 ↗
21. Lopez-Esteban S, Gutierrez-Gonzalez CF, Gremillard L, Saiz E, Tomsia AP (2009) Interfaces in graded coatings on titanium-based implants. J Biomed Mater Res A 88:1010–102110.1002/jbm.a.31935 ↗
22. Yang S, Wang J, Tang L, Ao H, Tan H, Tang T, Liu C (2014) Mesoporous bioactive glass doped-poly (3-hydroxybutyrate-co-3-hydroxyhexanoate) composite scaffolds with 3-dimensionally hierarchical pore networks for bone regeneration. Colloids Surf B: Biointerfaces 116:72–8010.1016/j.colsurfb.2013.12.052 ↗
23. Boccaccini AR, Peters C, Roether JA, Eifler D, Misra SK, Minay EJ (2006) Electrophoretic deposition of polyetheretherketone (PEEK) and PEEK/Bioglass coatings on NiTi shape memory alloy wires. J Mater Sci 41:8152–815910.1007/s10853-006-0556-z ↗
24. Fiorilli S, Baino F, Cauda V, Crepaldi M, Vitale-Brovarone C, Demarchi D, Onida B (2015) Electrophoretic deposition of mesoporous bioactive glass on glass-ceramic foam scaffolds for bone tissue engineering. J Mater Sci Mater Med 26:2110.1007/s10856-014-5346-6 ↗
25. Baino F, Vitale-Brovarone C (2015) Feasibility of glass-ceramic coatings on alumina prosthetic implants by airbrush spraying method. Ceram Int 41:2150–215910.1016/j.ceramint.2014.10.015 ↗
26. Baino F, Vitale-Brovarone C (2015) Wollastonite-containing bioceramic coatings on alumina substrates: design considerations and mechanical modelling. Ceram Int 41:11464–1147010.1016/j.ceramint.2015.05.111 ↗
27. Verné E, Vitale-Brovarone C, Robiglio L, Baino F (2008) Single-piece ceramic prosthesis elements. Patent no. EP2152328 (WO 2008/146322 A2)
28. Vitale-Brovarone C, Baino F, Tallia F, Gervasio C, Verné E (2012) Bioactive glass-derived trabecular coating: a smart solution for enhancing osteointegration of prosthetic elements. J Mater Sci Mater Med 23:2369–238010.1007/s10856-012-4643-1 ↗
29. Baino F, Tallia F, Novajra G, Minguella J, Montealegre MA, Korkusuz F, Vitale-Brovarone C (2015) Novel bone-like porous glass coatings on Al2O3 prosthetic substrates. Key Eng Mater 631:236–24010.4028/www.scientific.net/KEM.631.236 ↗
30. Baino F, Vitale-Brovarone C (2015) Trabecular coating on curved alumina substrates using a novel bioactive and strong glass-ceramic. Biomed Glasses 1:31–4010.1515/bglass-2015-0003 ↗
31. Baino F, Minguella J, Kirk N, Montealegre MA, Fiaschi C, Korkusuz F, Orlygsson G, Vitale-Brovarone C (2016) Novel full-ceramic monoblock acetabular cup with a bioactive trabecular coating: design, fabrication and characterization. Ceram Int 42:6833–684510.1016/j.ceramint.2016.01.065 ↗
32. Gmeiner R, Deisinger U, Schonherr J, Lechner B, Detsch R, Boccaccini AR, Stampfl J (2015) Additive manufacturing of bioactive glasses and silicate bioceramics. J Ceram Sci Technol 6:75–86
33. Comesaña R, Lusquiños F, Del Val J, López-Álvarez M, Quintero F, Riveiro A, Boutinguiza M, De Carlos A, Jones JR, Hill RG, Pou J (2011) Three-dimensional bioactive glass implants fabricated by rapid prototyping based on CO2 laser cladding. Acta Biomater 7:3476–348710.1016/j.actbio.2011.05.023 ↗
34. Comesana R, Lusquinos F, Del Val J, Malot T, López-Álvarez M, Riveiro A, Quintero F, Boutinguiza M, Aubry P, De Carlos A, Pou J (2011) Calcium phosphate grafts produced by rapid prototyping based on laser cladding. J Eur Ceram Soc 31:29–4110.1016/j.jeurceramsoc.2010.08.011 ↗
35. Del Val J, López-Cancelos R, Riveiro A, Badaoui A, Lusquiños F, Quintero F, Comesaña R, Boutinguiza M, Pou J (2016) On the fabrication of bioactive glass implants for bone regeneration by laser assisted rapid prototyping based on laser cladding. Ceram Int 42:2021–203510.1016/j.ceramint.2015.10.009 ↗
36. Lusquiños F, Pou J, Arias JL, Boutinguiza M, Pérez-Amor M, León B, Pérez-Amor M, Driessens FCM, Merry JC, Gibson I, Best S, Bonfield W (2001) Production of calcium phosphate coatings on Ti6Al4V obtained by Nd:yttrium–aluminum–garnet laser cladding. J Appl Phys 90:4231–423610.1063/1.1402975 ↗
37. Lusquiños F, De Carlos A, Pou J, Arias JL, Boutinguiza M, León B, Pérez-Amor M, Driessens FCM, Hing K, Gibson I, Best S, Bonfield W (2003) Calcium phosphate coatings obtained by Nd:YAG laser cladding: physico-chemical and biological properties. J Biomed Mater Res 64:630–63710.1002/jbm.a.10440 ↗
38. Lusquiños F, Pou J, Boutinguiza M, Quintero F, Soto R, León B, Perez-Amor M (2005) Main characteristics of calcium phosphate coatings obtained by laser cladding. Appl Surf Sci 247:486–49210.1016/j.apsusc.2005.01.134 ↗
39. Comesaña R, Quintero F, Lusquiños F, Pascual MJ, Boutinguiza M, Durán A, Pou J (2010) Laser cladding of bioactive glass coatings. Acta Biomater 6:953–96110.1016/j.actbio.2009.08.010 ↗
40. Minguella J, Cuiñas D, Rodríguez JV, Vivancos J (2013) Advanced manufacturing of ceramics for biomedical applications: subjection methods for biocompatible materials. Proc Eng 63:218–22410.1016/j.proeng.2013.08.219 ↗
41. ISO 14577-4 (2007) Metallic materials—Instrumented indentation test for hardness and materials parameters. Part 4: Test method for metallic and non-metallic coatings
42. Oliver WC, Pharr GM (1992) An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J Mater Res 7:1564–158310.1557/JMR.1992.1564 ↗
43. Kokubo T, Takadama H (2006) How useful is SBF in predicting in vivo bone bioactivity? Biomaterials 27:2907–291510.1016/j.biomaterials.2006.01.017 ↗
44. Kokubo T, Ito S, Sakka S, Yamamuro T (1986) Formation of a high strength bioactive glass-ceramic in the system MgO–CaO–SiO2–P2O5. J Mater Sci 21:536–54010.1007/BF01145520 ↗
45. Rehman I, Knowles JC, Bonfield W (1998) Analysis of in vitro reaction layers formed on Bioglass® using thin-film X-ray diffraction and ATR-FTIR microspectroscopy. J Biomed Mater Res 41:162–16610.1002/(SICI)1097-4636(199807)41:1<162::AID-JBM19>3.0.CO;2-P ↗
46. Saboori A, Rabiee M, Moztarzadeh F, Sheikhi M, Tahriri M, Karimi M (2009) Synthesis, characterization and in vitro bioactivity of sol-gel-derived SiO2–CaO–P2O5–MgO bioglass. Mater Sci Eng, C 29:335–34010.1016/j.msec.2008.07.004 ↗
47. Ma J, Chen CZ, Wang DG, Meng XG, Shi JZ (2010) Influence of the sintering temperature on the structural feature and bioactivity of sol-gel derived SiO2–CaO–P2O5 bioglass. Ceram Int 36:1911–191610.1016/j.ceramint.2010.03.017 ↗
48. Fernandes JS, Gentile P, Moorehead Crawford A, Miller CA, Pires RA, Hatton PV, Reis RL (2016) Design and properties of novel substituted borosilicate bioactive glasses and their glass-ceramic derivatives. Cryst Growth Design 16:3731–374010.1021/acs.cgd.6b00231 ↗
49. Gautam C, Kumar Yadav A, Kumar Singh A (2012) A review on infrared spectroscopy of borate glasses with effects of different additives. Int Scholarly Res Network ISRN Ceram 42849710.5402/2012/428497 ↗
50. Teghil R, D’Alessio L, Ferro D, Barinov SM (2002) Hardness of bioactive glass film deposited on titanium alloy by pulsed laser ablation. J Mater Sci Lett 21:379–38210.1023/A:1014903117057 ↗
51. Nychka JA, Li D, Alexander B (2008) In vitro bioactivity of 45S5 bioactive glass as a function of indentation load. J Mech Behav Biomed Mater 1:243–25110.1016/j.jmbbm.2007.11.004 ↗
52. Tang CY, Tsui CP, Janackovic DJ, Uskokovic PS (2006) Nanomechanical properties evaluation of bioactive glass coatings on titanium alloy substrate. J Optoelectronics Adv Mater 8:1194–1199
53. Shahgholi M, Oliviero S, Baino F, Vitale-Brovarone C, Gastaldi D, Vena P (2016) Mechanical characterization of glass-ceramic scaffolds at multiple characteristic lengths through nanoindentation. J Eur Ceram Soc 36:2403–240910.1016/j.jeurceramsoc.2016.01.042 ↗
54. Chalker PR, Bull SJ, Rickerby DS (1991) A review of the methods for the evaluation of coating-substrate adhesion. Mater Sci Eng, A 140:583–59210.1016/0921-5093(91)90482-3 ↗
55. Gomez-Vega JM, Saiz E, Tomsia AP, Marshall GW, Marshall SJ (2000) Bioactive glass coatings with hydroxyapatite and Bioglass® particle on Ti-based implants. 1. Processing. Biomaterials 21:105–11110.1016/S0142-9612(99)00131-3 ↗
56. ISO 13779-4 (2002) Implants for surgery—Hydroxyapatite—part 4: determination of coating adhesion strength
57. Karageorgiou V, Kaplan D (2005) Porosity of 3D biomaterial scaffolds and osteogenesis. Biomaterials 26:5474–549110.1016/j.biomaterials.2005.02.002 ↗
58. Jones JR (2013) Review of bioactive glass: from Hench to hybrids. Acta Biomater 9:4457–448610.1016/j.actbio.2012.08.023 ↗
59. Rahaman MN, Day DE, Bal BS, Fu Q, Jung SB, Bonewald LF, Tomsia AP (2011) Bioactive glass in tissue engineering. Acta Biomater 7:2355–237310.1016/j.actbio.2011.03.016 ↗