Flexible, wearable microfluidic contact lens with capillary networks for tear diagnostics
Source abstract
Abstract
Wearable contact lenses attract great interest as a minimally invasive diagnostic platform. With advances in biomaterials, electronics and microfabrication, contact lenses offer the potential to analyze the concentration of biomarkers of interest in tears. Emerging wearable contact lenses typically involve external electrodes and batteries, signal processing and wireless transmission, which is accompanied by increased stiffness in the contact lenses and do not have direct means for detecting tears or storing small volumes of tears. Here, we developed a UV-curable biomaterial with good biocompatibility, hydrophilicity and elasticity for fabricating flexible, wearable contact lenses. The contact lens defined a set of tear inlets that allowed tears to flow spontaneously through the capillary network and reservoirs. The previously embedded chemical substrates responded via colorimetric methods to biomarkers in the tears, such as glucose, chloride and urea. Then, the external device took pictures and read the RGB values in the photos to obtain the concentration range of the biomarkers. Furthermore, in vitro tests using an artificial microfluidic hydrogel eyeball device demonstrated the convenient and reliable operation of the lens. Our work offers a new paradigm for noninvasive, multi-target microfluidic contact lenses with capillary networks for tear storage and diagnostics. The fabricated contact lens could serve as an immense point-of-care diagnostic platform in the future.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ocular Surface and Contact Lens · Advanced Sensor and Energy Harvesting Materials · Polydiacetylene-based materials and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Pankratov D, Gonzalez-Arribas E, Blum Z, Shleev S (2016) Tear based bioelectronics. Electroanalysis 28(6):1250–126610.1002/elan.201501116 ↗
2. van Delft JL, Meijer F, van Best JA, van Haeringen NJ (1997) Permeability of blood-tear barrier to fluorescein and albumin after application of platelet-activating factor to the eye of the guinea pig. Mediat Inflamm 6(5–6):381–38310.1080/09629359791532 ↗
3. Khuri RN (1994) U.S. Patent No. 5,352,411. Washington, DC: U.S. Patent and Trademark Office
4. Harvey D, Hayes NW, Tighe B (2012) Fibre optics sensors in tear electrolyte analysis: towards a novel point of care potassium sensor. Contact Lens Anterio 35(3):137–14410.1016/j.clae.2012.02.004 ↗
5. Farandos NM, Yetisen AK, Monteiro MJ, Lowe CR, Yun SH (2015) Contact lens sensors in ocular diagnostics. Adv Healthc Mater 4(6):792–81010.1002/adhm.201400504 ↗
6. Yetisen AK, Jiang N, Tamayol A, Ruiz-Esparza GU, Zhang YS, Medina-Pando S, Gupta A, Wolffsohn JS, Butt H, Khademhosseini A, Yun SH (2017) Paper-based microfluidic system for tear electrolyte analysis. Lab Chip 17(6):1137–114810.1039/C6LC01450J ↗
7. Boehm N, Funke S, Wiegand M, Wehrwein N, Pfeiffer N, Grus FH (2013) Alterations in the tear proteome of dry eye patients-a matter of the clinical phenotype. Invest Ophth Vis Sci 54(3):2385–239210.1167/iovs.11-8751 ↗
8. Baca JT, Finegold DN, Asher SA (2007) Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus. Ocul Surf 5(4):280–29310.1016/S1542-0124(12)70094-0 ↗
9. Chu MX, Miyajima K, Takahashi D, Arakawa T, Sano K, Sawada S, Kudo H, Iwasaki Y, Akiyoshi K, Mochizuki M, Mitsubayashi K (2011) Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment. Talanta 83(3):960–96510.1016/j.talanta.2010.10.055 ↗
10. Jacob JT, Ham B (2008) Compositional profiling and biomarker identification of the tear film. Ocul Surf 6(4):175–18510.1016/S1542-0124(12)70178-7 ↗
11. Moreddu R, Vigolo D, Yetisen AK (2019) Contact lens technology: from fundamentals to applications. Adv Healthc Mater 8(15):190036810.1002/adhm.201900368 ↗
12. Maulvi FA, Lakdawala DH, Shaikh AA, Desai AR, Choksi HH, Vaidya RJ, Ranch KM, Koli AR, Vyas BA, Shah DO (2016) In vitro and in vivo evaluation of novel implantation technology in hydrogel contact lenses for controlled drug delivery. J Control Release 226:47–5610.1016/j.jconrel.2016.02.012 ↗
13. Jiang N, Montelongo Y, Butt H, Yetisen AK (2018) Microfluidic contact lenses. Small 14(15):e170436310.1002/smll.201704363 ↗
14. Senior M (2014) Novartis signs up for Google smart lens. Nat Biotechnol 32(9):85610.1038/nbt0914-856 ↗
15. Choi K, Park HG (2017) Smart reinvention of the contact lens with graphene. ACS Nano 11(6):5223–522610.1021/acsnano.7b03180 ↗
16. Kim J, Kim M, Lee MS, Kim K, Ji S, Kim YT, Park J, Na K, Bae KH, Kim HK, Bien F, Lee CY, Park JU (2017) Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics. Nat Commun 8:1499710.1038/ncomms14997 ↗
17. Mak WC, Cheung KY, Orban J, Lee CJ, Turner APF, Griffith M (2015) Surface-engineered contact lens as an advanced theranostic platform for modulation and detection of viral infection. Acs Appl Mater Inter 7(45):25487–2549410.1021/acsami.5b08644 ↗
18. Song C, Ben-Shlomo G, Que L (2019) A multifunctional smart soft contact lens device enabled by nanopore thin film for glaucoma diagnostics and in situ drug delivery. J Microelectromech Syst 28(5):810–81610.1109/JMEMS.2019.2927232 ↗
19. Lee S, Jo I, Kang S, Jang B, Moon J, Park JB, Lee S, Rho S, Kim Y, Hong BH (2017) Smart contact lenses with graphene coating for electromagnetic interference shielding and dehydration protection. ACS Nano 11(6):5318–532410.1021/acsnano.7b00370 ↗
20. Park J, Kim J, Kim SY, Cheong WH, Jang J, Park YG, Na K, Kim YT, Heo JH, Lee CY, Lee JH, Bien F, Park JU (2018) Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays. Sci Adv 4(1):984110.1126/sciadv.aap9841 ↗
21. Pandey J, Liao YT, Lingley A, Mirjalili R, Parviz B, Otis BP (2010) A fully integrated RF-powered contact lens with a single element display. IEEE Trans Biomed Circ S 4(6):454–46110.1109/TBCAS.2010.2081989 ↗
22. Liao YT, Yao HF, Lingley A, Parviz B, Otis BP (2012) A 3-mu W CMOS glucose sensor for wireless contact-lens tear glucose monitoring. IEEE J Solid-St Circ 47(1):335–34410.1109/JSSC.2011.2170633 ↗
23. De Smedt S (2015) Noninvasive intraocular pressure monitoring: current insights. Clin Ophthalmol (Auckland, NZ) 9:1385–139210.2147/OPTH.S53772 ↗
24. Elder JA (2003) Ocular effects of radio frequency energy. Bioelectromagnetics 24(S6):S148–S16110.1002/bem.10117 ↗
25. Van Lith R, Baker E, Ware H, Yang J, Farsheed AC, Sun C, Ameer G (2016) 3D-printing strong high-resolution antioxidant bioresorbable vascular stents. Adv Mater Technol 1(9):160013810.1002/admt.201600138 ↗
26. Sun MH, Luo CX, Xu LP, Ji H, Qi OY, Yu DP, Chen Y (2005) Artificial lotus leaf by nanocasting. Langmuir 21(19):8978–898110.1021/la050316q ↗
27. Olanrewaju A, Beaugrand M, Yafia M, Juncker D (2018) Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits. Lab Chip 18(16): 2323–234710.1039/C8LC00458G ↗
28. Bavil AK, Kim J (2018) A capillary flow-driven microfluidic system for microparticle-labeled immunoassays. Analyst 143(14):3335–334210.1039/C8AN00898A ↗
29. Young T (1805) III. An essay on the cohesion of fluids. Philos Trans R Soc Lond 95:65–87
30. Delamarche E, Bernard A, Schmid H, Bietsch A, Michel B, Biebuyck H (1998) Microfluidic networks for chemical patterning of substrate: design and application to bioassays. J Am Chem Soc 120(3):500–50810.1021/ja973071f ↗
31. Eijkel JCT, van den Berg A (2006) Young 4ever: the use of capillarity for passive flow handling in lab on a chip devices. Lab Chip 6(11):1405–140810.1039/B613839J ↗
32. Zhongkuan L, Xinwang D, Huiyuan H (2016) Preparation and properties of PHEMA hydrogel material. Rare Metal Mater Eng 45:427–430
33. Acun A, Hasirci V (2014) Construction of a collagen-based, split-thickness cornea substitute. J Biomater Sci Polym Ed 25(11):1110–113210.1080/09205063.2014.920170 ↗
34. Chetty S, Gruppetta S (2012) Structured illumination microscopy for in vivo human retinal imaging: a theoretical assessment. Opt Express 20(23):25700–2571010.1364/OE.20.025700 ↗
35. Farkas A, Vamos R, Bajor T, Mullner N, Lazar A, An H (2003) Utilization of lacrimal urea assay in the monitoring of hemodialysis: conditions, limitations and lacrimal arginase characterization. Exp Eye Res 76(2):183–19210.1016/S0014-4835(02)00276-2 ↗