journal article·2018-02

Controllably degradable transient electronic antennas based on water-soluble PVA/TiO2 films

Fang Xu, Huaiwu Zhang, Lichuan Jin, Yuanxun Li, Jie Li, Gongwen Gan, Miaoqin Wei, Mingming Li, Yulong Liao

Journal of Materials Science· Volume 53· Issue 4
Publisher page

Abstract

Transient electronic is an emerging field that designed electronic devices can be fleetly and partially (or completely) degraded when transiency is triggered. Here, a class of PVA-based degradable composite film was synthesized, whose physical properties allow it to be used as substrate material for transient electronic devices. We found the dielectric properties and dissolution rate of the composite film can be tuned by controlling the TiO2 nanoparticle addition. Based on the as-synthesized PVA/TiO2 composite film, patch antennas were further designed and fabricated. The antennas were found to possess excellent radiation performances at a frequency of 2.5 GHz. Most importantly, the antennas could be physically degraded within 1 h when immersed in pure water. This study shows that the PVA-based film is a good candidate substrate or supporting material for transient electronics. In addition, the design and manufacture methods reported here provide a reference for other transient devices with complex structure and function.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Nanomaterials and Printing Technologies · Electrospun Nanofibers in Biomedical Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Hwang SW, Tao H, Kim DH et al (2012) A physically transient form of silicon electronics. Science 337:1640–1644. doi: 10.1126/science.122632510.1126/science.1226325 ↗
2. Kim DH, Kim YS, Amsden J et al (2009) Silicon electronics on silk as a path to bioresorbable, implantable devices. Appl Phys Lett 95:133701–133703. doi: 10.1063/1.323855210.1063/1.3238552 ↗
3. Berggren M, Richter-Dahlfors A (2007) Organic bioelectronics. Adv Mater 19:3201–3213. doi: 10.1002/adma.20070041910.1002/adma.200700419 ↗
4. Kang SK, Murphy RKJ, Hwang SW et al (2016) Bioresorbable silicon electronic sensors for the brain. Nature 530:71–76. doi: 10.1038/nature1649210.1038/nature16492 ↗
5. Fu KK, Wang ZY, Dai JQ, Carter M, Hu LB (2016) Transient electronics: materials and devices. Chem Mater 28:3527–3539. doi: 10.1021/acs.chemmater.5b0493110.1021/acs.chemmater.5b04931 ↗
6. Gao Y, Zhang Y, Wang X et al (2017) Moisture-triggered physically transient electronics. Sci Adv 3:e.1701222–e.1701229. doi: 10.1126/sciadv.170122210.1126/sciadv.1701222 ↗
7. Gao Y, Sim K, Yan X, Jiang J, Xie JW, Yu CJ (2017) Thermally triggered mechanically destructive electronics based on electrospun poly(epsilon-caprolactone) nanofibrous polymer films. Sci Rep 7:947–955. doi: 10.1038/s41598-017-01026-610.1038/s41598-017-01026-6 ↗
8. Yin L, Huang X, Xu HX et al (2014) Materials, designs, and operational characteristics for fully biodegradable primary batteries. Adv Mater 26:3879–3884. doi: 10.1002/adma.20130630410.1002/adma.201306304 ↗
9. Dong ZF, Wang Q, Du YM (2006) Alginate/gelatin blend films and their properties for drug controlled release. J Membr Sci 280:37–44. doi: 10.1016/j.memsci.2006.01.00210.1016/j.memsci.2006.01.002 ↗
10. Acar H, Cinar S, Thunga M, Kessler MR, Hashemi N, Montazami R (2014) Study of physically transient insulating materials as a potential platform for transient electronics and bioelectronics. Adv Funct Mater 24:4135–4143. doi: 10.1002/adfm.20130418610.1002/adfm.201304186 ↗
11. Hwang SW, Song JK, Huang X et al (2014) High-performance biodegradable/transient electronics on biodegradable polymers. Adv Mater 26:3905–3911. doi: 10.1002/adma.20130605010.1002/adma.201306050 ↗
12. Hernandez HL, Kang SK, Lee OP et al (2014) Triggered transience of metastable poly(phthalaldehyde) for transient electronics. Adv Mater 26:7637–7642. doi: 10.1002/adma.20140304510.1002/adma.201403045 ↗
13. Jain RA (2000) The manufacturing techniques of various drug loaded biodegradable poly(lactide-co-glycolide) (PLGA) devices. Biomaterials 21:2475–2490. doi: 10.1016/s0142-9612(00)00115-010.1016/s0142-9612(00)00115-0 ↗
14. Grayson ACR, Voskerician G, Lynn A, Anderson JM, Cima MJ, Langer R (2004) Differential degradation rates in vivo and in vitro of biocompatible poly(lactic acid) and poly(glycolic acid) homo- and co-polymers for a polymeric drug delivery microchip. J Biomater Sci Polym Ed 15:1281–1304. doi: 10.1163/156856204195999110.1163/1568562041959991 ↗
15. Sim K, Wang X, Li YH et al (2017) Destructive electronics from electrochemical-mechanically triggered chemical dissolution. J Micromech Microeng 27:065010–065018. doi: 10.1088/1361-6439/aa682f10.1088/1361-6439/aa682f ↗
16. Park CW, Kang SK, Hernandez HL et al (2015) Thermally triggered degradation of transient electronic devices. Adv Mater 27:3783–3788. doi: 10.1002/adma.20150118010.1002/adma.201501180 ↗
17. Wang XQ, Yucel T, Lu Q, Hu X, Kaplan DL (2010) Silk nanospheres and microspheres from silk/PVA blend films for drug delivery. Biomaterials 31:1025–1035. doi: 10.1016/j.biomaterials.2009.11.00210.1016/j.biomaterials.2009.11.002 ↗
18. Yang DZ, Li YN, Nie J (2007) Preparation of gelatin/PVA nanofibers and their potential application in controlled release of drugs. Carbohydr Polym 69:538–543. doi: 10.1016/j.carbpol.2007.01.00810.1016/j.carbpol.2007.01.008 ↗
19. Liu TY, Hu SH, Liu KH, Liu DM, Chen SY (2008) Study on controlled drug permeation of magnetic-sensitive ferrogels: effect of Fe3O4 and PVA. J Control Release 126:228–236. doi: 10.1016/j.jconrel.2007.12.00610.1016/j.jconrel.2007.12.006 ↗
20. Frosini V, Butta E, Calamia M (1967) Dielectric behavior of some polar high polymers at ultra-high frequencies (microwaves). J Appl Polym Sci 11:527–55110.1002/app.1967.070110404 ↗
21. Yang CC (2007) Synthesis and characterization of the cross-linked PVA/TiO2 composite polymer membrane for alkaline DMFC. J Membr Sci 288:51–60. doi: 10.1016/j.memsci.2006.10.04810.1016/j.memsci.2006.10.048 ↗
22. Rao JK, Raizada A, Ganguly D, Mankad MM, Satayanarayana SV, Madhu GM (2015) Investigation of structural and electrical properties of novel CuO–PVA nanocomposite films. J Mater Sci 50:7064–7074. doi: 10.1007/s10853-015-9261-010.1007/s10853-015-9261-0 ↗
23. Wu TM, Cheng JC, Yan MC (2003) Crystallization and thermoelectric behavior of conductive-filler-filled poly(1-caprolactone)/poly(vinyl butyral)/montmorillonite nanocomposites. Polymer 44:2553–2562. doi: 10.1016/s0032-3861(03)00106-x10.1016/s0032-3861(03)00106-x ↗
24. Andrade GI, Barbosa-Stancioli EF, Mansur AAP, Vasconcelos WL, Mansur HS (2008) Small-angle X-ray scattering and FTIR characterization of nanostructured poly (vinyl alcohol)/silicate hybrids for immunoassay applications. J Mater Sci 43:450–463. doi: 10.1007/s10853-007-1953-710.1007/s10853-007-1953-7 ↗
25. Shehap AM, Akil DS (2016) Structural and optical properties of TiO2 nanoparticles/PVA for different composites thin films. Int J Nanoelectron Mater 9:17–36
26. Skipetrov SE (1999) Effective dielectric function of a random medium. Phys Rev B 60:12705–12709. doi: 10.1103/PhysRevB.60.1270510.1103/PhysRevB.60.12705 ↗
27. Maex K, Baklanov MR, Shamiryan D, Iacopi F, Brongersma SH, Yanovitskaya ZS (2003) Low dielectric constant materials for microelectronics. J Appl Phys 93:8793–8841. doi: 10.1063/1.156746010.1063/1.1567460 ↗
28. Choudhary S, Sengwa RJ (2017) Anomalous behavior of the dielectric and electrical properties of polymeric nanodielectric poly(vinyl alcohol)–titanium dioxide films. J Appl Polym Sci 134::44568–44579. doi: 10.1002/app.4456810.1002/app.44568 ↗
29. Song LN, Myers AC, Adams JJ, Zhu Y (2014) Stretchable and reversibly deformable radio frequency antennas based on silver nanowires. ACS Appl Mater Interfaces 6:4248–4253. doi: 10.1021/am405972e10.1021/am405972e ↗