journal article·2015-01Open access

Performing elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy-dispersive X-ray spectrometry (SEM/SDD-EDS)

Dale E. Newbury, Nicholas W. M. Ritchie

Journal of Materials Science· Volume 50· Issue 2

Abstract

Abstract Electron-excited X-ray microanalysis performed in the scanning electron microscope with energy-dispersive X-ray spectrometry (EDS) is a core technique for characterization of the microstructure of materials. The recent advances in EDS performance with the silicon drift detector (SDD) enable accuracy and precision equivalent to that of the high spectral resolution wavelength-dispersive spectrometer employed on the electron probe microanalyzer platform. SDD-EDS throughput, resolution, and stability provide practical operating conditions for measurement of high-count spectra that form the basis for peak fitting procedures that recover the characteristic peak intensities even for elemental combination where severe peak overlaps occur, such PbS, MoS2, BaTiO3, SrWO4, and WSi2. Accurate analyses are also demonstrated for interferences involving large concentration ratios: a major constituent on a minor constituent (Ba at 0.4299 mass fraction on Ti at 0.0180) and a major constituent on a trace constituent (Ba at 0.2194 on Ce at 0.00407; Si at 0.1145 on Ta at 0.0041). Accurate analyses of low atomic number elements, C, N, O, and F, are demonstrated. Measurement of trace constituents with limits of detection below 0.001 mass fraction (1000 ppm) is possible within a practical measurement time of 500 s.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · X-ray Spectroscopy and Fluorescence Analysis · Surface and Thin Film Phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Castaing R (1951) Application of electron probes to metallographic analysis. Ph.D. Dissertation, University of Paris
2. Goldstein J, Newbury D, Joy D, Lyman C, Echlin P, Lifshin E, Sawyer L, Michael J (2003) Scanning electron microscopy and X-ray microanalysis, 3rd edn. Springer, New York10.1007/978-1-4615-0215-9 ↗
3. Heinrich K (1981) Electron beam X-ray microanalysis. Van Nostrand Reinhold, New York, pp 99–140
4. Yakowitz H (1968) Evaluation of specimen preparation and the use of standards in electron probe microanalysis. In: Fifty years of progress in metallographic techniques, ASTM-special technical publication 430. American Society of Testing and Materials, Philadelphia 430, pp 383–40810.1520/STP41831S ↗
5. Yakowitz H (1975) Methods of quantitative analysis. In: Goldstein JI, Yakowitz H, Newbury DE, Lifshin E, Colby JW, Coleman JR (eds.) Practical scanning electron microscopy. Plenum, New York, p 338 (error histogram derived from Heinrich K, Yakowitz H, Vieth D (1972) Proceedings of 7th conference electron probe analysis, Microanalysis Society)
6. Fitzgerald R, Keil K, Heinrich KFJ (1968) Solid-state energy-dispersion spectrometer for electron-microprobe X-ray analysis. Science 528:159–160
7. Reed SJB, Ware NG (1973) Quantitative electron microprobe analysis using a lithium drifted silicon detector. X-Ray Spectrom 2:69–7410.1002/xrs.1300020206 ↗
8. Schamber FC (1973) A new technique for deconvolution of complex X-ray energy spectra. In: Proceedings of 8th national conference on electron probe analysis. Electron Probe Analysis Society of America, New Orleans, p 85
9. Statham P, Long J, White G, Kandiah K (1974) Quantitative analysis with an energy dispersive detector using a pulsed electron probe and active signal filtering. X-Ray Spectrom 3:153–15810.1002/xrs.1300030407 ↗
10. Fiori CE, Myklebust RL, Heinrich KFJ, Yakowitz H (1976) Prediction of continuum intensity in energy-dispersive X-ray microanalysis. Anal Chem 48:172–17610.1021/ac60365a022 ↗
11. Myklebust R, Fiori C, Heinrich K (1979) FRAME C: a compact procedure for quantitative energy-dispersive electron probe X-ray analysis. National Bureau of Standards Tech. Note 1106 (Spectral processing techniques in a quantitative energy dispersive X-ray microanalysis procedure (FRAME C). In: Heinrich K, Newbury D, Myklebust R, Fiori C (eds) Energy dispersive X-ray spectrometry, U.S. Dept of Commerce, National Bureau of Standards Special Pub. 604 (1981) pp 365–379)10.6028/NBS.TN.1106 ↗
12. Fiori CE, Swyt CR, Myklebust RL (1992) Desktop spectrum analyzer. Office of standard reference data. National Institute of Standards and Technology, Gaithersburg
13. Newbury DE (2000) Energy-dispersive spectrometry. In: Kaufmann EN et al (eds) Methods in materials research. Wiley, New York, pp 11d.1.1-11d.1.25 (reissued as EN Kaufmann
14. (ed) (2003) Characterization of materials. ISBN: 0-471-26882-8)
15. Newbury DE, Swyt CR, Myklebust RL (1995) “Standardless” quantitative electron probe microanalysis with energy-dispersive X-ray spectrometry: is it worth the risk? Anal Chem 67:1866–187110.1021/ac00107a017 ↗
16. Newbury DE, Ritchie NWM (2013) Is scanning electron microscopy/energy dispersive spectrometry (SEM/EDS) quantitative? Scanning 35:141–16810.1002/sca.21041 ↗
17. Newbury DE (2005) Misidentification of major constituents by automatic qualitative energy dispersive X-ray microanalysis: a problem that threatens the credibility of the analytical community. Microsc Microanal 11:545–56110.1017/S1431927605050531 ↗
18. Newbury DE (2007) Mistakes encountered during automatic peak identification in low beam energy X-ray microanalysis. Scanning 29:137–15110.1002/sca.20009 ↗
19. Newbury DE (2009) Mistakes encountered during automatic peak identification of minor and trace constituents in electron-excited energy dispersive X-Ray microanalysis. Scanning 31:1–1110.1002/sca.20151 ↗
20. Newbury DE, Ritchie NWM (2011) Is scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) quantitative? Effects of specimen shape. In: SPIE proceedings, vol 8036, pp 803601-1–803602-16
21. Struder L, Fiorini C, Gatti E, Hartmann R, Holl P, Krause N, Lechner P, Longoni A, Lutz G, Kemmer J, Meidinger N, Popp M, Soltau H, van Zanthier C (1998) High resolution non dispersive X-ray spectroscopy with state of the art silicon detectors. Mikrochim Acta 15:11–19
22. Newbury DE (2006) Electron-excited energy dispersive X-ray spectrometry at high speed and at high resolution: silicon drift detectors and microcalorimeters. Microsc Microanal 12:527–53710.1017/S1431927606060673 ↗
23. Newbury DE, Ritchie NWM (2013) Quantitative SEM/EDS, step 1: what constitutes a sufficiently flat specimen? Microsc Microanal 19(Suppl 2):1244–124510.1017/S1431927613008210 ↗
24. Ritchie NWM, NIST DTSA-II software, including tutorials. www.cstl.nist.gov/div837/837.02/epq/dtsa2/index.html
25. Ritchie NWM, Newbury DE (2012) Uncertainty estimates for electron probe X-ray microanalysis measurements. Anal Chem 84:9956–996210.1021/ac301843h ↗
26. Ritchie NWM, Newbury DE, Davis JM (2012) EDS measurements at WDS precision and accuracy using a silicon drift detector. Microsc Microanal 18:892–90410.1017/S1431927612001109 ↗
27. Bastin G, Heijligers H (1991) Quantitative electron probe microanalysis of ultralight elements boron-oxygen. In: Heinrich K, Newbury D (eds) Electron probe quantitation. Plenum, New York, pp 163–17510.1007/978-1-4899-2617-3_9 ↗