Stretchable, Antifreeze, and Water-Retaining Silk Fibroin-Based Ionic Conductive Hydrogel for Wearable Sensors
Source abstract
Abstract
Silk fibroin shows great potential for epidermal electronics and implantable medical devices due to its excellent biocompatibility. However, its practical application as a hydrogel is limited by poor mechanical properties, low water retention, and freezing susceptibility. To address these challenges, we developed a composite ionic conductive hydrogel (SF-PAM) from polyacrylamide and silk fibroin. This material exhibits outstanding mechanical performance with an elongation rate of 1663%, a tensile strength of 0.38 MPa, and a toughness of 12.58 kJ m –2, alongside excellent biocompatibility. Enhanced by lithium ions and sodium carboxylate pyrrolidone, SF-PAM achieves remarkable water retention (90% after 30 days) and antifreeze capabilities (unfrozen at −70 °C). A strain sensor made from SF-PAM demonstrates a wide detection range of 1 to 1200%. Additionally, we integrated this sensor into a smart cart, enabling a wearable electronic skin system that allows precise control through finger movements detected by a smart glove, significantly improving motion monitoring and user experience in wearable technology.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Conducting polymers and applications · Silk-based biomaterials and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Physics College of Physical Science and Technology Research Institution for Biomimetics and Soft Matter
Xiamen University
Funding
Fundamental Research Funds for the Central Universities · National Natural Science Foundation of China · Higher Education Discipline Innovation Project
References (32)
Show source-provided references
1. Correction to “A Highly Stretchable, Conductive, and Transparent Bioadhesive Hydrogel as a Flexible Sensor for Enhanced Real-Time Human Health Monitoring”. Adv. Mater. 2024, 36(44), e241279210.1002/adma.20241279210.1002/adma.202412792 ↗
2. 10.1016/j.cej.2024.15547510.1016/j.cej.2024.155475 ↗
3. 10.1002/adfm.20240160710.1002/adfm.202401607 ↗
4. 10.1002/adsr.20240000310.1002/adsr.202400003 ↗
5. 10.1002/adma.20241627510.1002/adma.202416275 ↗
6. 10.1126/scirobotics.adp359310.1126/scirobotics.adp3593 ↗
7. 10.1038/s41467-024-55323-610.1038/s41467-024-55323-6 ↗
8. 10.1038/s41563-024-01955-410.1038/s41563-024-01955-4 ↗
9. 10.1021/acsnano.3c0525310.1021/acsnano.3c05253 ↗
10. 10.1002/adfm.20231633910.1002/adfm.202316339 ↗
11. 10.1016/j.cej.2024.15887910.1016/j.cej.2024.158879 ↗
12. 10.1016/j.colsurfb.2022.11250910.1016/j.colsurfb.2022.112509 ↗
13. 10.1002/advs.20220105910.1002/advs.202201059 ↗
14. 10.1002/smll.20231164710.1002/smll.202311647 ↗
15. 10.1016/j.carbpol.2024.12206810.1016/j.carbpol.2024.122068 ↗
16. 10.1016/j.ijbiomac.2024.13435610.1016/j.ijbiomac.2024.134356 ↗
17. 10.1002/adfm.20240285310.1002/adfm.202402853 ↗
18. 10.1002/adfm.20241980910.1002/adfm.202419809 ↗
19. 10.1016/j.cej.2024.15870010.1016/j.cej.2024.158700 ↗
20. 10.1002/adma.20180012910.1002/adma.201800129 ↗
21. 10.1002/adma.20210022110.1002/adma.202100221 ↗
22. 10.1039/D3TA05537J10.1039/D3TA05537J ↗
23. 10.1002/adfm.20240445110.1002/adfm.202404451 ↗
24. 10.1016/j.cej.2022.13693110.1016/j.cej.2022.136931 ↗
25. 10.1007/s10570-024-05762-710.1007/s10570-024-05762-7 ↗
26. 10.1021/acs.iecr.1c0335810.1021/acs.iecr.1c03358 ↗
27. 10.1021/acsami.2c0178510.1021/acsami.2c01785 ↗
28. 10.1002/adfm.20221102710.1002/adfm.202211027 ↗
29. 10.1016/j.cej.2024.15077510.1016/j.cej.2024.150775 ↗
30. 10.1021/acsnano.3c1157810.1021/acsnano.3c11578 ↗
31. 10.1002/adfm.20241172510.1002/adfm.202411725 ↗
32. 10.1002/smll.20240787010.1002/smll.202407870 ↗