Mechanism-driven recoil performance in auxetic structures: Numerical modeling and additive manufacturing verification
Source abstract
Abstract
This study presents a novel auxetic mechanical structure (AMS) designed to reduce recoil in stents application. Building upon a peanut-shaped auxetic lattice with a negative Poisson’s ratio, various single- and double-layer AMS configurations were developed by integrating friction-based (clamp, tubular, elliptical interlocking) and locking-based (locking, ratchet) mechanisms. Finite element analysis (FEA) and additive-manufactured prototypes were employed to evaluate mechanical performance, focusing on recoil mitigation, expansion uniformity, and structural integrity. Results demonstrated that locking-based mechanisms significantly improve recoil resistance, reducing recoil to 3.9% in the single-layer locking design and 5.4% in the double-layer ratchet design, compared to 100% recoil in unmodified structures. Friction-based mechanisms provide moderate improvements but require optimization of clamping force and contact area. Despite minor increases in relative density, AMS designs maintain the auxetic response and expand effective surface area, advantageous for drug delivery. Overall, the AMS approach provides a robust and adaptable design strategy for reducing recoil on auxetic structure. However, further optimization and validation across different auxetic geometries and materials are required to enhance clinical applicability.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Cellular and Composite Structures · Topology Optimization in Engineering · Additive Manufacturing and 3D Printing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (64)
Show source-provided references
1. Biocompatible polymer materials with antimicrobial properties for preparation of stents10.3390/nano9111548 ↗
2. Cardiovascular stents: types and future landscape
3. Drug-eluting stents: technical and clinical progress10.3390/biomimetics8010072 ↗
4. Pheophorbide a and paclitaxel bioresponsive nanoparticles as double-punch platform for cancer therapy10.3390/pharmaceutics13081130 ↗
5. Self‐expanding versus balloon expandable stent for intracranial arterial stenosis: a systematic review and meta‐analysis10.1111/jon.13188 ↗
6. Comparative efficacy and safety of self-expandable vs. balloon-expandable stent grafts in visceral artery aneurysm management10.3390/diagnostics14151695 ↗
7. US multicenter experience with the wingspan stent system for the treatment of intracranial atheromatous disease: periprocedural results10.1161/01.STR.0000257963.65728.e8 ↗
8. A study on designing balloon expandable magnesium alloy stent for optimization of mechanical characteristics
9. Manufacturing, processing, and characterization of self-expanding metallic stents: a comprehensive review10.3390/bioengineering11100983 ↗
10. Optimization of polymer coating thickness and strut width in drug eluting stents using magnetic field10.1016/j.ejpb.2024.114455 ↗
11. Designing better cardiovascular stent materials: a learning curve10.1002/adfm.202005361 ↗
12. Structural design of vascular stents: a review10.3390/mi12070770 ↗
13. Evaluation of coronary stents: a review of types, materials, processing techniques, and complications including recoil, dog-boning, and foreshortening10.1016/j.heliyon.2023.e13575 ↗
14. Numerical analysis for non-uniformity of balloon-expandable stent deployment driven by dogboning and foreshortening10.1007/s13239-021-00573-4 ↗
15. Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning10.1371/journal.pone.0224026 ↗
16. Structural design and mechanical properties of metal vascular stents fabricated via laser powder bed fusion
17. Factors associated with chronic stent recoil and its impact on revascularization: a serial optical coherence tomography study10.1016/j.jcin.2025.01.432 ↗
18. A novel double arrowhead auxetic coronary stent10.1016/j.compbiomed.2023.107525 ↗
19. Mechanical behavior of a new stent with negative poisson's ratio: the influence of geometric parameters10.1142/S0219519423501087 ↗
20. Revolutionary auxetic intravascular medical stents for angioplasty applications10.1016/j.matdes.2023.112393 ↗
21. 3D printing of biodegradable polymer vascular stents to treat cardiovascular diseases: a review
22. Advances in additive manufacturing of auxetic structures for biomedical applications
23. Auxetic coronary stent endoprosthesis: fabrication and structural analysis
24. Design of self-expanding auxetic stents using topology optimization10.3389/fbioe.2020.00736 ↗
25. Cellular auxetic structures for mechanical metamaterials: a review10.3390/s20113132 ↗
26. Origami derived self-assembly stents fabricated via 4D printing10.1016/j.compstruct.2022.115669 ↗
27. From in vitro to in vivo: diverse applications of kirigami technology in medical devices
28. On the auxetic properties of rotating rhombi and parallelograms: a preliminary investigation10.1002/pssb.200777705 ↗
29. 3D printed auxetic cardiovascular stents: a state-of-the-art review on topological design, manufacturing, mechanical and biological properties
30. Bio-inspired auxetic mechanical metamaterials evolved from rotating squares unit10.1016/j.mechmat.2022.104421 ↗
31. Multiscale experimental characterization of nonlinear mechanics and auxeticity in mechanical metamaterials with rotating squares10.1016/j.compstruct.2025.118931 ↗
32. Computational optimisation of the cassini oval aperture auxetic metamaterial
33. Deformation and energy absorption characteristics of graded auxetic metamaterials featuring peanut-shaped perforations under in-plane compression10.1016/j.ijsolstr.2025.113318 ↗
34. A novel two-dimensional mechanical metamaterial with negative Poisson's ratio10.1016/j.commatsci.2019.109232 ↗
35. Investigation into the shape memory behavior of peanut-pattern auxetic structures10.3144/expresspolymlett.2022.50 ↗
36. Performance evaluation of peanut-shaped tubular auxetics with enhanced stiffness: a finite element study10.1088/1361-651X/aca5a4 ↗
37. Additive manufacturing and mechanical properties of auxetic and non-auxetic Ti24Nb4Zr8Sn biomedical stents: a combined experimental and computational modelling approach10.3390/cryst13111592 ↗
38. Bending resistance and transverse energy absorption behaviors of auxetic tubes with orthogonal pattern of peanut-shaped perforations
39. Acute stent recoil: in vivo evaluation of different stent designs
40. The platinum chromium element stent platform: from alloy, to design, to clinical practice10.1007/s12325-010-0022-9 ↗
41. Effect of stent design on reduction of elastic recoil: a comparison via quantitative intravascular ultrasound
42. Composite tree-like re-entrant structure with high stiffness and controllable elastic anisotropy10.1016/j.ijsolstr.2020.09.003 ↗
43. Novel 3D auxetic lattice structures developed based on the rotating rigid mechanism10.1016/j.ijsolstr.2021.111232 ↗
44. A stretchable sandwich panel metamaterial with auxetic rotating-square surface10.1016/j.ijmecsci.2023.108334 ↗
45. Additive manufacturing-enabled advanced design and process strategies for multi-functional lattice structures10.3390/ma17143398 ↗
46. Design, fabrication, and properties evaluation of novel nested lattice structures
47. Review of mechanics and applications of auxetic structures
48. Progress in auxetic mechanical metamaterials: structures, characteristics, manufacturing methods, and applications10.1002/adem.202000312 ↗
49. Auxetics and FEA: modern materials driven by modern simulation methods10.3390/ma17071506 ↗
50. Auxetic 3D printed metastructure stents for enhanced mechanical and structural performance and biocompatibility in coronary artery treatments10.1016/j.actbio.2025.06.043 ↗
51. Design, development and manufacturing of re-entrant auxetic stent implant for enhanced mechanical attributes
52. Multi-objective optimization of auxetic coronary stents based on finite element simulation and surrogate modeling10.1080/10255842.2025.2556003 ↗
53. Mechanical compliance and anti-migration performance of auxetic tracheal stents with multi-circular cores10.1177/09544119251380165 ↗
54. Compressive properties of 3D printed auxetic structures: experimental and numerical studies10.1080/17452759.2019.1644184 ↗
55. Mechanical and biological characteristics of 3D-printed auxetic structure in bone tissue engineering10.1016/j.jbiomech.2025.112685 ↗
56. Experimental and finite element analysis of a novel symmetric auxetic structures under compression test: a case study with abaqus
57. Tensile behavior of an auxetic structure: analytical modeling and finite element analysis10.1016/j.ijmecsci.2017.12.029 ↗
58. Tensile properties of an auxetic structure with re-entrant and chiral features—a finite element study10.1007/s00170-018-2637-y ↗
59. Euler buckling
60. Mechanical design of antichiral-reentrant hybrid intravascular stent10.1142/S1758825118501053 ↗
61. Computational analysis of mechanical performance for composite polymer biodegradable stents10.3390/ma14206016 ↗
62. Conceptual design and analysis of novel hybrid auxetic stents with superior expansion10.1016/j.mechmat.2023.104813 ↗
63. A review on powder bed fusion technology of metal additive manufacturing10.1201/9781315119106-15 ↗
64. A review of stereolithography: processes and systems10.3390/pr8091138 ↗