journal article·2025-11Open access

Microstructure refinement and in vivo evaluation of biodegradable magnesium metal matrix composites

Pedram Sotoudehbagha, Alison Grise, Andrew Romero, Andres Larraza, Sun Latt, Abel Córdova Flores, Kayley Romero, John Lovejoy, Mehdi Razavi

Abstract

The incorporation of bioactive ceramic particles can enhance the bioactivity of bioabsorbable magnesium (Mg) implants. In this study, a melt shearing process was implemented using a rotor-stator assembly to effectively disperse bioactive glass-ceramic (BG) nanoparticles in the Mg melt during casting. The microstructural, electrochemical, and mechanical properties, as well as in vitro cell behavior of the Mg-5wt.%BG composite prepared using the melt shearing process were compared to a Mg-5wt.%BG composite that was manually mixed (Mg-5BG manual) and to pure Mg. Two metallic wire meshes with pore sizes of 250 μm and 2000 μm were mounted on a wide-opening stator to investigate the effect of pore size on stator performance. The grain size distribution revealed a mixture of an equiaxed rosette-like dendritic structure (rosette-like) and equiaxed grains with a non-dendritic (globular) structure for Mg-5BG shear 250 (76.4 ± 15.7 μm) and a globular structure for Mg-5BG shear 2000 (136.9 ± 44.1 μm) compared to elongated grains in pure Mg (234.1 ± 163.8 μm) and rosette-like structure in Mg-5BG manual (121.4 ± 37.6 μm). Additionally, SEM/EDS analysis confirmed a uniform and narrower distribution of BG particles in the Mg-5BG shear 2000 (∼2–4 μm) compared to the unevenly distributed particles in the Mg-5BG manual (∼7–40 μm). The addition of 5 wt% of BG to Mg melt resulted in the appearance of monticellite (CaMgSiO 4 ), magnesium oxide (MgO), and magnesium silicide (Mg 2 Si). Mg-5BG shear 2000 exhibited smaller pits after the removal of corrosion products compared to Mg-5BG manual. Mg-5BG shear 2000 and Mg-5BG manual showed slightly increased ultimate compressive strength values (177 ± 7.22 MPa and 172.9 ± 23.96 MPa, respectively) compared to pure Mg (151.8 ± 4.90 MPa, p > 0.05). Electrochemical testing revealed that Mg-5BG shear 2000 had a higher corrosion current density (i corr = 47.2 ± 18.7 μA/cm 2 ) and a less negative corrosion potential (E corr = −1.47 ± 0.03 V) than both pure Mg (i corr = 5.24 ± 1.60 μA/cm 2 , E corr = −1.56 ± 0.02 V) and Mg-5BG manual (i corr = 6.87 ± 1.14 μA/cm 2 , E corr = −1.62 ± 0.04 V). In vitro cytocompatibility assay indicated high cell viability with 10 % extracts, although reduced viability was observed with 100 % extracts. In vivo implantation in a rat femur model was conducted with four groups: intact (without surgery), sham (drilled without an implant), pure Mg implant, and Mg-5BG shear 2000 implant. The Mg-5BG shear 2000 implant revealed superior bone regeneration and callus formation, as assessed by Nano-CT and X-ray imaging, alongside complete or partial implant resorption without observable histological signs of systemic toxicity in muscle, liver, or kidney tissues at 28 days. These findings suggest that Mg-5BG shear 2000 composites could be a promising candidate for bioactive, absorbable bone implants.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · MXene and MAX Phase Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Bone fracture acute phase response-A unifying theory of fracture repair: clinical and scientific implications10.1007/s12018-018-9256-x ↗
2. Surgical enhancement of fracture healing - operative vs. nonoperative treatment10.1016/j.injury.2020.11.049 ↗
3. Do all fractures need surgery?
4. The use of titanium and stainless steel in fracture fixation10.1586/erd.10.53 ↗
5. Elective removal vs. retaining of hardware after osteosynthesis in asymptomatic patients-a scoping review10.1186/s13643-020-01488-2 ↗
6. Development of degradable magnesium-based metal implants and their function in promoting bone metabolism (A review)10.1016/j.jot.2022.09.013 ↗
7. Fracture healing physiology and the quest for therapies for delayed healing and nonunion10.1002/jor.23460 ↗
8. Revision surgery using retrograde nail versus replating in nonunion distal femur fracture treated with plate10.1155/2022/5742743 ↗
9. Healing, nonunion, and re-operation after internal fixation of diaphyseal and distal femoral fractures: a systematic review and meta-analysis10.1007/s00264-018-3864-4 ↗
10. Advances and challenges in polymer-based scaffolds for bone tissue engineering: a path towards personalized regenerative medicine10.3390/polym16233303 ↗
11. Principles of nonunion management: state of the art10.1097/BOT.0000000000001122 ↗
12. Biomechanical comparison of biodegradable magnesium screws and titanium screws for operative stabilization of displaced capitellar fractures10.1016/j.jse.2020.02.009 ↗
13. Bioabsorbable vs. titanium screws for first tarsometatarsal joint arthrodesis: an in-vitro study10.1016/j.jcot.2019.08.017 ↗
14. Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study10.1186/1475-925X-12-62 ↗
15. A review on magnesium alloys for biomedical applications
16. Results of the use of bioabsorbable magnesium screws for surgical treatment of mason type II radial head fractures10.4055/cios23074 ↗
17. Magnesium-based alloys used in orthopedic surgery10.3390/ma15031148 ↗
18. Magnesium-based biomaterials as emerging agents for bone repair and regeneration: from mechanism to application10.1016/j.jma.2021.03.004 ↗
19. Biodegradable magnesium-based implants in Orthopedics—a general review and perspectives10.1002/advs.201902443 ↗
20. Processing and properties of biodegradable magnesium Microtubes for using as vascular sents: a brief review10.1007/s12540-019-00285-4 ↗
21. In vivo monitoring the biodegradation of magnesium alloys with an electrochemical H2 sensor10.1016/j.actbio.2016.03.039 ↗
22. Degradation characteristics of high-purity magnesium implants under single static and cyclic compressive loads in vivo and in vitro10.1016/j.jma.2024.12.014 ↗
23. Toward tailoring the degradation rate of magnesium-based biomaterials for various medical applications: assessing corrosion, cytocompatibility and immunological effects10.3390/ijms22020971 ↗
24. Advances in biodegradable orthopaedic implants: optimizing magnesium alloy corrosion resistance for enhanced bone repair10.1007/s44174-024-00208-x ↗
25. Additive manufacturing of magnesium alloys
26. Development of a novel magnesium alloy with high degradation resistance and osteo/angiogenesis activity through scandium‐enhanced growth of passivation film
27. High-performance ultra-lean biodegradable Mg–Ca alloys and guidelines for their processing10.1016/j.actamat.2024.120247 ↗
28. In vivo degradation behavior of magnesium alloy for bone implants with improving biological activity, mechanical properties, and corrosion resistance10.3390/ijms24021602 ↗
29. Preparation and evaluation of HA–PP coating on AZ31B magnesium alloy for implant applications10.1177/02670844241235763 ↗
30. In vivo safety of new coating for biodegradable magnesium implants10.3390/ma16175807 ↗
31. New biodegradable Mg–Zn–Ca bulk metallic glass composite with large plasticity reinforced by SnZn alloy10.1016/j.msea.2023.145045 ↗
32. Biodegradable Mg-Fe interpenetrating-phase composites by reactive melt infiltration10.1016/j.msea.2025.148876 ↗
33. The critical role of nano-hydroxyapatites as an advanced scaffold in drug delivery towards efficient bone regeneration: recent progress and challenges10.1016/j.carpta.2025.100692 ↗
34. Nanoparticles in bone regeneration: a narrative review of current advances and future directions in tissue engineering10.3390/jfb15090241 ↗
35. Comprehensive study of magnesium based metal matrix composite10.1016/j.matpr.2021.04.062 ↗
36. Fabrication and processing of magnesium-based metal matrix nanocomposites for bioabsorbable implants10.3390/met14121318 ↗
37. Assessment and improvement of melt quality of Recycled secondary A357 alloy by application of the high shear melt conditioning (HSMC) technology10.3390/cryst14121044 ↗
38. Degassing of aluminum alloy melts by high shear melt conditioning technology: an overview10.3390/met12101772 ↗
39. Fabrication of biodegradable nano-sized β-TCP/Mg composite by a novel melt shearing technology10.1016/j.msec.2012.03.017 ↗
40. The hot deformation behavior and microstructure evolution of HA/Mg-3Zn-0.8Zr composites for biomedical application10.1016/j.msec.2017.03.239 ↗
41. Strength retention, corrosion control and biocompatibility of Mg–Zn–Si/HA nanocomposites10.1016/j.jmbbm.2019.103584 ↗
42. Effects of MgO modified β-TCP nanoparticles on the microstructure and properties of β-TCP/Mg-Zn-Zr composites
43. Investigation of microstructure, texture evolution and plastic anisotropy of short-time homogenized MS-DC cast 2024 aluminum alloy during rolling and annealing10.1016/j.msea.2024.146392 ↗
44. Numerical simulation of the flow field and temperature field in direct-chill casting of 2024 aluminium alloy under the influence of intensive melt shearing10.1016/j.jmrt.2022.12.030 ↗
45. Diopside-based bioactive glass-ceramic nanoparticles for osteoimmunomodulation10.1016/j.ceramint.2025.05.405 ↗
46. Mixing and agitation
47. International · 2024
48. International · 2023
49. International · 2015
50. 2012
51. BoneJ2 - refactoring established research software10.12688/wellcomeopenres.16619.1 ↗
52. The non-dendritic microstructure arising from grain boundary formation and wetting: a phase-field simulation and experimental investigation of semi-solid deformation10.1016/j.matdes.2022.111111 ↗
53. In-situ microstructural control of A6082 alloy to modify second phase particles by melt conditioned direct chill (MC-DC) casting process – a novel approach
54. Preparation and rheo-squeeze casting of semi-solid AZ91–2 wt% Ca magnesium alloy by gas bubbling process10.1557/jmr.2015.36 ↗
55. Liquid metal engineering by application of intensive melt shearing
56. Chapter 2 - severe plastic deformation methods for bulk samples
57. Sustainable magnesium recycling: insights into grain refinement through plastic deformation-assisted solid-state recycling (SSR)10.1016/j.jma.2024.10.016 ↗
58. Solid-state recycling of magnesium and its alloys via plastic deformation: an overview of processing and properties10.1016/j.jmrt.2024.07.032 ↗
59. Semisolid rheoforming of magnesium alloys: a review10.1016/j.matdes.2020.108990 ↗
60. In situ observations of dendritic fragmentation due to local solute-enrichment during directional solidification of an aluminum alloy10.1016/j.actamat.2007.03.030 ↗
61. Morphological development of solidification structures under forced fluid flow: a Monte-Carlo simulation10.1016/S1359-6454(02)00305-1 ↗
62. Solidification behavior of Sn-15 wt pct Pb alloy under a high shear rate and high intensity of turbulence during semisolid processing10.1007/s11661-002-0338-4 ↗
63. A model of growth morphology for semi-solid metals10.1016/j.actamat.2004.04.005 ↗
64. Solidification behaviour under intensive forced convection10.1016/j.msea.2005.09.037 ↗
65. Melt flow-induced mechanical deformation of dendrites in alloy solidification: a coupled thermal fluid - solid mechanics approach10.1016/j.jmrt.2023.06.222 ↗
66. Novel magnesium nanocomposite for wire-Arc directed energy deposition10.3390/ma17020500 ↗
67. A thermodynamic analysis of the Mg-Si system10.1361/105497100770339914 ↗
68. Microstructure and mechanical property correlation of Mg-Si alloys10.1007/s12633-021-01521-6 ↗
69. Mechanisms of grain refinement by intensive shearing of AZ91 alloy melt10.1016/j.actamat.2010.08.016 ↗
70. Microstructure refinement and mechanical properties of eutectic Mg2Si reinforced Mg matrix composites containing Sr element10.1016/j.jmrt.2022.02.035 ↗
71. The development of binary Mg-Ca alloys for use as biodegradable materials within bone10.1016/j.biomaterials.2007.12.021 ↗
72. Investigating local corrosion processes of magnesium alloys with scanning probe electrochemical techniques: a review10.1016/j.jma.2022.09.024 ↗
73. High shear dispersion technology prior to twin roll casting for high performance magnesium/SiC p metal matrix composite strip fabrication10.1016/j.compositesa.2016.07.025 ↗
74. Comparative investigation on antibacterial, biological and mechanical behaviour of monticellite and diopside derived from biowaste for bone regeneration10.1016/j.matchemphys.2022.126157 ↗
75. Coating bone-like apatite onto organic substrates using solutions mimicking body fluid10.1002/term.3 ↗
76. A template route to the preparation of mesoporous amorphous calcium silicate with high in vitro bone-forming bioactivity10.1002/jbm.b.30813 ↗
77. Nanoscale characterization of the interface between bone and hydroxyapatite implants and the effect of silicon on bone apposition10.1016/j.micron.2006.03.006 ↗
78. Apatite formation on bioactive calcium-silicate cements for dentistry affects surface topography and human marrow stromal cells proliferation10.1016/j.dental.2010.06.002 ↗
79. Apatite formation in Hanks' solution on β-Ca2SiO4 films prepared by MOCVD10.1016/j.surfcoat.2011.07.014 ↗
80. Novel fast-setting calcium silicate bone cements with high bioactivity and enhanced osteogenesis in vitro10.1039/b819033j ↗
81. Carbonate formation on sol-gel bioactive glass 58S and on Bioglass® 45S5
82. Synthesis and characterization of bioactive quaternary silicate gel-glasses10.1088/1742-6596/1082/1/012070 ↗
83. Rosehip extract-functionalized magnesium hydroxide nanoparticles and its effect on osteoblastic and osteoclastic cells10.3390/ma14154172 ↗
84. Preoperative canal bone ratio is related to high-degree stress shielding: a minimum 5-year Follow-up study of a proximally hydroxyapatite-coated straight tapered titanium femoral component10.1016/j.arth.2017.12.019 ↗
85. Bioresorbability, porosity and mechanical strength of bone substitutes: what is optimal for bone regeneration?10.1016/j.injury.2011.06.008 ↗
86. Hall-Petch relationship and deformation mechanism of pure Mg at room temperature10.1016/j.jallcom.2022.165924 ↗
87. Back stress strengthening and strain hardening in gradient structure10.1080/21663831.2016.1153004 ↗
88. Microstructure and mechanical properties of SiC nanoparticles reinforced magnesium matrix composites fabricated by ultrasonic vibration10.1016/j.msea.2011.03.061 ↗
89. Magnesium matrix composite reinforced by nanoparticles – a review10.1016/j.jma.2020.08.018 ↗
90. Mechanical and corrosion properties of Mg–MgO and Mg–Al2O3 composites fabricated by equal channel angular extrusion method10.1016/j.smmf.2022.100010 ↗
91. High temperature wettability and corrosion of ZrO2, Al2O3, Al2O3-C, MgO and MgAlON ceramic substrates by an AZ91 magnesium alloy melt10.1016/j.jeurceramsoc.2022.01.040 ↗
92. Improved cytotoxicity testing of magnesium materials10.1016/j.mseb.2011.04.008 ↗
93. 2009
94. Effects of magnesium degradation products on mesenchymal stem cell fate and osteoblastogenesis10.1016/j.gene.2015.08.028 ↗
95. Recommendation for modifying current cytotoxicity testing standards for biodegradable magnesium-based materials10.1016/j.actbio.2015.04.011 ↗
96. Magnesium ions regulate mesenchymal stem cells population and osteogenic differentiation: a fuzzy agent-based modeling approach10.1016/j.csbj.2021.07.005 ↗
97. Dynamic in vivo monitoring of fracture healing process in response to magnesium implant with multimodal imaging: pilot longitudinal study in a rat external fixation model10.1039/D2BM00051B ↗
98. Intramedullary Mg2Ag nails augment callus formation during fracture healing in mice10.1016/j.actbio.2016.03.041 ↗
99. Implant-derived magnesium induces local neuronal production of CGRP to improve bone-fracture healing in rats10.1038/nm.4162 ↗
100. High-purity magnesium pin enhances bone consolidation in distraction osteogenesis model through activation of the VHL/HIF-1α/VEGF signaling10.1177/0885328220928550 ↗