Sensitivity-Controllable Liquid-Metal-Based Pressure Sensor for Wearable Applications
Source abstract
Abstract
Liquid-metal-based sensors have great opportunities in various applications such as health monitoring, intelligent artificial skin, and soft robotics. However, current liquid-metal-based pressure sensors suffer from low pressure sensitivity, low signal reliability, and poor interconnection properties. This paper introduces a sensitivity-engineerable, reliable liquid-metal-based pressure sensor with a robust interconnection structure for multifunctional wearable applications. Herein, we investigated the effects of dimensions of rigid microbumps on the liquid-metal-based soft pressure sensor. Furthermore, two different types of rigid microbump structures such as embedded bump (E-bump) and anchored bump (A-bump) were designed and integrated with a liquid metal microchannel using multimaterial 3D printing technology, and it enabled the engineering of pressure sensitivity for different purposes. High sensitivity was achieved with E-bump structures, and a robust interconnection structure was realized with A-bump structures. Integration of E-bumps has increased the average sensitivity of the sensor to 0.0727 kPa–1 (5.43 times higher), and A-bump integration has decreased the average sensitivity to 0.0004 Pa–1 (91.65 times lower) in the range of 0–50 kPa, as compared to the pressure sensor without any microbumps. Therefore, the liquid metal interconnection was established with the A-bump structures for reliable pressure monitoring in practical wearable applications. These characteristics allow the demonstration of the multifunctional wearable electronic applications, including a fingertip pressure sensor glove for wireless multiposition wrist pulse monitoring as traditional East Asian medicine pulse diagnosis and a wireless human–machine interface device.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Tactile and Sensory Interactions · Muscle activation and electromyography studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea
Funding
National Research Foundation of Korea
References (30)
Show source-provided references
1. 10.1021/nn503454h10.1021/nn503454h ↗
2. 10.1002/adfm.20140037910.1002/adfm.201400379 ↗
3. 10.1021/nn103523t10.1021/nn103523t ↗
4. 10.1002/adma.20130474210.1002/adma.201304742 ↗
5. 10.1016/j.carbon.2014.05.02210.1016/j.carbon.2014.05.022 ↗
6. 10.1002/adfm.20120049810.1002/adfm.201200498 ↗
7. 10.3390/s806371910.3390/s8063719 ↗
8. 10.1021/nn501204t10.1021/nn501204t ↗
9. 10.1002/adma.20110340610.1002/adma.201103406 ↗
10. 10.1038/nature1400210.1038/nature14002 ↗
11. 10.1039/C4NR03295K10.1039/C4NR03295K ↗
12. 10.3390/s1807239510.3390/s18072395 ↗
13. 10.1021/acsami.7b0039810.1021/acsami.7b00398 ↗
14. 10.1021/acsami.9b0778610.1021/acsami.9b07786 ↗
15. 10.1021/acsomega.7b0157510.1021/acsomega.7b01575 ↗
16. 10.1021/acssensors.6b0011510.1021/acssensors.6b00115 ↗
17. 10.1002/adma.20170198510.1002/adma.201701985 ↗
18. 10.1088/0960-1317/26/2/02501110.1088/0960-1317/26/2/025011 ↗
19. 10.1002/adhm.20190097810.1002/adhm.201900978 ↗
20. 10.1088/0960-1317/20/12/12502910.1088/0960-1317/20/12/125029 ↗
21. 10.1063/1.476721710.1063/1.4767217 ↗
22. 10.1109/JSEN.2013.227232010.1109/JSEN.2013.2272320 ↗
23. 10.4103/2229-5186.7934510.4103/2229-5186.79345 ↗
24. Tang A. C. Y. · 2012 · 61
25. 10.1002/adfm.20180341310.1002/adfm.201803413 ↗
26. 10.3390/s1902038610.3390/s19020386 ↗
27. Kabigting, J. E.; Chen, A. D.; Chang, E. J.H.; Lee, W.N.; Roberts, R. C. MEMS pressure sensor array wearable for traditional Chinese medicine pulse-taking. In 2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN); IEEE, 2017; pp 59–62.10.1109/BSN.2017.7936007 ↗
28. 10.1016/j.eujim.2012.03.00310.1016/j.eujim.2012.03.003 ↗
29. Wang, P.; Zuo, W.; Zhang, H.; Zhang, D. Design and implementation of a multi-channel pulse signal acquisition system. In 2012 5th International Conference on BioMedical Engineering and Informatics; IEEE, 2012; pp 1063–1067.10.1109/BMEI.2012.6512884 ↗
30. 10.1039/C7LC00426E10.1039/C7LC00426E ↗