journal article·2019-05-01

Undercut and Grouted Anchors as Post-Installed Shear Reinforcement

Authors not provided

ACI Structural Journal· Volume 116· Issue 3
Publisher page

Abstract

First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Invalid Email Address
Only a short abstract or summary was supplied by the source.
Source: openalex_inverted_index · Quality: short

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Joint ACI-ASCE Committee 326, “Shear and Diagonal Tension,” ACI Journal Proceedings, V. 59, No. 1-3, Jan.-Mar., 1962, pp. 1-30, 277-344, and 352-396.
2. ACI Committee 364, “Increasing Shear Capacity within Existing Reinforced Concrete Structures (ACI 364.2T-08),” American Concrete Institute, Farmington Hills, MI, 2008, 4 pp.
3. Kunz, J., and Randl, N., “Strengthening and Design of Shear Beams,” Tailor Made Concrete Structures, J. C. Walraven and D. Stoelhorst, eds., 2008, pp. 657-663.
4. Kunz, J., “Strengthening with Post-installed Shear Reinforcement,” Conservation of Structures, 2013, pp. 154-158.
5. Ruiz, M. F.; Muttoni, A.; and Kunz, J., “Strengthening of Flat Slabs against Punching Shear Using Post-Installed Shear Reinforcement,” ACI Structural Journal, V. 107, No. 4, July-Aug. 2010, pp. 434-442.10.14359/51663816 ↗
6. Heymsfield, E., and Durham, S. A., “Retrofitting Short-Span Precast Channel Beam Bridges Constructed without Shear Reinforcement,” Journal of Bridge Engineering, ASCE, V. 16, No. 3, 2011, pp. 445-452. doi: 10.1061/(ASCE)BE.1943-5592.000016710.1061/(ASCE)BE.1943-5592.0000167 ↗
7. Barros, J. A. O., and Dalfré, G. M., “Assessment of the Effectiveness of the Embedded Through-Section Technique for the Shear Strengthening of Reinforced Concrete Beams,” Strain, V. 49, No. 1, 2013, pp. 75-93. doi: 10.1111/str.1201610.1111/str.12016 ↗
8. Chaallal, O.; Mofidi, A.; Benmokrane, B.; and Neale, K., “Embedded Through-Section FRP Rod Method for Shear Strengthening of RC Beams: Performance and Comparison with Existing Techniques,” Journal of Composites for Construction, ASCE, V. 15, No. 3, 2011, pp. 374-383. doi: 10.1061/(ASCE)CC.1943-5614.000017410.1061/(ASCE)CC.1943-5614.0000174 ↗
9. Randl, N., “Research on Post-Installed Reinforcement for Structural Retrofitting,” Proceedings of 18th Congress of IABSE, Seoul, South Korea, 2012, 5 pp.10.2749/222137912805112086 ↗
10. ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14),” American Concrete Institute, Farmington Hills, MI, 2014, 520 pp.
11. AASHTO LRFD Bridge Design Specifications, seventh edition, American Association of State and Highway Transportation Officials, Washington, DC, 2014.
12. Bissonnette, B.; Vaysburd, A. M.; and Von Fay, K. F., “Best Practices for Preparing Concrete Surfaces Prior to Repairs and Overlays,” Report No. MERL 12-17, U.S. Department of the Interior, Bureau of Reclamation, Denver, CO, 2012.
13. Cook, R. A.; Collins, D. M.; Klingner, R. E.; and Polyzois, D., “Load-Deflection Behavior of Cast-in-Place and Retrofit Concrete Anchors,” ACI Structural Journal, V. 89, No. 6, Nov.-Dec. 1992, pp. 639-649.10.14359/4134 ↗
14. Zamora, N. A.; Cook, R. A.; Konz, R. C.; and Consolazio, G. R., “Behavior and Design of Single, Headed and Unheaded, Grouted Anchors under Tensile Load,” ACI Structural Journal, V. 100, No. 2, Mar.-Apr. 2003, pp. 222-230.10.14359/12486 ↗
15. Collins, M. P., and Kuchma, D., “How Safe Are Our Large, Lightly Reinforced Concrete Beams, Slabs, and Footings?” ACI Structural Journal, V. 96, No. 4, July-Aug. 1999, pp. 482-491.10.14359/684 ↗
16. Wight, J. K., and MacGregor, J. G., Reinforced Concrete Mechanics and Design, sixth edition, Pearson, Boston, MA, 2012.