Effect of annealing on magnetic properties of Ni–Mn–Ga glass-coated microwires
Source abstract
Abstract
We studied the effect of annealing on magnetic properties and structure of Heusler-type NiMnGa glass-covered microwires with a metallic nucleus diameter of about 22 µm prepared using the Taylor–Ulitovsky method. The as-prepared NiMnGa glass-covered microwires do not present ferromagnetic order at room temperature. Magnetization curves of the as-prepared samples do not present either saturation or coercivity at temperatures above 5 K. After annealing of the microwires, a ferromagnetic ordering is obtained with a Curie temperature of about 300 K which is beneficial for magnetic solid state refrigeration. The hysteresis observed on temperature dependence of magnetization in annealed samples and magnetic softening at about 260 K has been interpreted as the first-order phase transformation. Observed changes have been discussed considering internal stress relaxation after annealing, nanocrystalline structure of the as-prepared and annealed samples, recrystallization process and magnetic ordering of phases identified in the as-prepared sample and appearing under recrystallization. Existence of insulating and flexible glass-coating is beneficial for improvement of mechanical properties but the glass coating considerably affects magnetic properties of NiMnGa microwires. Therefore special attention must be paid to annealing conditions for realization of martensitic transformation.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Magnetic Properties of Alloys · Metallic Glasses and Amorphous Alloys
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. 10.1016/j.intermet.2017.12.01610.1016/j.intermet.2017.12.016 ↗
2. 10.1016/j.jallcom.2013.04.08310.1016/j.jallcom.2013.04.083 ↗
3. 10.1002/adma.20100275310.1002/adma.201002753 ↗
4. 10.1063/1.486891910.1063/1.4868919 ↗
5. Hernando · 1994 · 260
6. 10.1103/PhysRevB.67.06440710.1103/PhysRevB.67.064407 ↗
7. 10.1063/1.326600910.1063/1.3266009 ↗
8. 10.1038/srep3930010.1038/srep39300 ↗
9. 10.1063/1.500457110.1063/1.5004571 ↗
10. 10.1063/1.344526510.1063/1.3445265 ↗
11. Effect of atomic order on the martensitic and magnetic transformations in Ni–Mn–Ga ferromagnetic shape memory alloys
12. 10.1016/j.intermet.2013.07.01010.1016/j.intermet.2013.07.010 ↗
13. 10.1063/1.275054010.1063/1.2750540 ↗
14. 10.3390/cryst702004110.3390/cryst7020041 ↗
15. 10.1088/0022-3727/33/10/30510.1088/0022-3727/33/10/305 ↗
16. 10.1007/s11664-008-0483-710.1007/s11664-008-0483-7 ↗
17. 10.1016/S0304-8853(02)00509-710.1016/S0304-8853(02)00509-7 ↗
18. 10.1016/j.actamat.2015.08.00210.1016/j.actamat.2015.08.002 ↗
19. 12. Ulitovsky A.V. , Maianski I.M. , and Avramenco A.I. : Method of continuous casting of glass coated microwire. USSR Patent No. 128427, Bulletin No. 10, 1960, p. 14.
20. 10.1063/1.36792610.1063/1.367926 ↗
21. Internal stress distribution in glass-covered amorphous magnetic wires
22. 10.1038/s41598-017-19032-z10.1038/s41598-017-19032-z ↗
23. 10.1007/BF0158689310.1007/BF01586893 ↗
24. Acet · 2011 · 19
25. 10.1063/1.149101810.1063/1.1491018 ↗
26. 10.1016/j.jallcom.2017.08.11910.1016/j.jallcom.2017.08.119 ↗
27. 10.1140/epjst/e2008-00673-310.1140/epjst/e2008-00673-3 ↗
28. 10.1016/j.jmmm.2012.02.08910.1016/j.jmmm.2012.02.089 ↗
29. 10.1016/S0167-577X(03)00305-710.1016/S0167-577X(03)00305-7 ↗
30. 10.1016/j.jallcom.2017.10.23210.1016/j.jallcom.2017.10.232 ↗
31. 10.1016/j.jmmm.2003.12.83610.1016/j.jmmm.2003.12.836 ↗
32. 10.1016/j.jallcom.2017.11.18710.1016/j.jallcom.2017.11.187 ↗
33. 10.1038/srep0887110.1038/srep08871 ↗
34. 10.1002/0470870508.ch1410.1002/0470870508.ch14 ↗
35. 10.1166/jnn.2012.654210.1166/jnn.2012.6542 ↗
36. 10.1063/1.324614910.1063/1.3246149 ↗
37. 10.1016/S0304-8853(97)00041-310.1016/S0304-8853(97)00041-3 ↗
38. 10.1016/S0304-8853(99)00240-110.1016/S0304-8853(99)00240-1 ↗
39. 10.1016/S1359-6462(98)00494-110.1016/S1359-6462(98)00494-1 ↗