Structural Responses of External Post-Tensioned Tendons to Increasing Localized Damage
Source abstract
Abstract
First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Invalid Email Address
Only a short abstract or summary was supplied by the source.
Source: openalex_inverted_index · Quality: short
Research context
OpenAlex topics: Concrete Corrosion and Durability · Structural Engineering and Vibration Analysis · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Virlogeux, M. P., “External Prestressing: From Construction History to Modern Technique and Technology,” External Prestressing in Bridges, SP-120, American Concrete Institute, Farmington Hills, MI, 1990, pp. 1-60.
2. Bruggeling, A. S. G., “External Prestressing: A State of the Art,” External Prestressing in Bridges, SP-120, American Concrete Institute, Farmington Hills, MI, 1990, pp. 61-82.
3. Poston, R. W.; Frank, K. H.; and West, J. S., “Enduring Strength,” Civil Engineering (New York, N.Y.), V. 73, No. 9, Sept. 2003, pp. 58-63.
4. Podolny, W., “Corrosion of Prestressing Steels and Its Mitigation,” PCI Journal, V. 37, No. 5, 1992, pp. 34-55. doi: 10.15554/pcij.09011992.34.5510.15554/pcij.09011992.34.55 ↗
5. Woodard, R. J., “Collapse of a Segmental Post-Tensioned Concrete Bridge,” Transportation Research Record 1211, Transportation Research Board, National Research Council, Washington, DC, 1989, pp. 38-59.
6. ACI Committee 222, “Corrosion of Prestressing Steels (ACI 222.2R-01),” American Concrete Institute, Farmington Hills, MI, 2001, 42 pp.
7. Corven Engineering, “Mid-Bay Bridge Post-Tensioning Evaluation,” Final Report to Florida Department of Transportation, 2001.
8. Cavell, D. G., and Waldron, P., “A Residual Strength Model for Deteriorating Post-Tensioned Concrete Bridge,” Computers & Structures, V. 79, No. 4, 2001, pp. 361-373. doi: 10.1016/S0045-7949(00)00150-410.1016/S0045-7949(00)00150-4 ↗
9. Coronelli, D.; Castel, A.; Vu, N. A.; and François, R., “Corroded Post-Tensioned Beams with Bonded Tendons and Wire Failure,” Engineering Structures, V. 31, No. 8, 2009, pp. 1687-1697. doi: 10.1016/j.engstruct.2009.02.04310.1016/j.engstruct.2009.02.043 ↗
10. Lee, J., “Evaluation of External Post-Tensioned Tendon using Vibration Signatures,” PhD dissertation, University of Texas at Austin, Austin, TX, 2007.
11. McKinstry, C. A., “Frequency Response of Damaged External Post-Tensioned Tendons,” MS thesis, University of Texas at Austin, Austin, TX, 2010.
12. Wood, S. L.; McKinstry, C. A.; and Lee, J., “Residual Tensile Capacity of Grouted, Post-Tensioned Tendons,” ACI Structural Journal, V. 110, No. 6, Nov.-Dec. 2013, pp. 1099-1107.10.14359/51686164 ↗
13. Irvine, M. H., Cable Structures, Dover Publications, Mineola, New York, 1981, pp. 42-46.
14. Fang, Z., and Wang, J., “Practical Formula for Cable Tension Estimation by Vibration Method,” Journal of Bridge Engineering, ASCE, V. 17, No. 1, 2012, pp. 161-164. doi: 10.1061/(ASCE)BE.1943-5592.000020010.1061/(ASCE)BE.1943-5592.0000200 ↗
15. Zui, H.; Shinke, T.; and Namita, Y., “Practical Formulas for Estimation of Cable Tension by Vibration Method,” Journal of Structural Engineering, ASCE, V. 122, No. 6, 1996, pp. 651-656. doi: 10.1061/(ASCE)0733-9445(1996)122:6(651)10.1061/(ASCE)0733-9445(1996)122:6(651) ↗
16. ASTM A416/A416M-10, “Standard Specification for Steel Strand, Uncoated Seven-Wire for Prestressed Concrete,” ASTM International, West Conshohocken, PA, 2010, 5 pp.
17. ASTM C942-10, “Standard Test Method for Compressive Strength of Grouts for Preplaced-Aggregate Concrete in the Laboratory,” ASTM International, West Conshohocken, PA, 2010, 3 pp.