journal article·2017-09-01

Structural Responses of External Post-Tensioned Tendons to Increasing Localized Damage

Authors not provided

ACI Structural Journal· Volume 114· Issue 5
Publisher page

Abstract

First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Invalid Email Address
Only a short abstract or summary was supplied by the source.
Source: openalex_inverted_index · Quality: short

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Engineering and Vibration Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Virlogeux, M. P., “External Prestressing: From Construction History to Modern Technique and Technology,” External Prestressing in Bridges, SP-120, American Concrete Institute, Farmington Hills, MI, 1990, pp. 1-60.
2. Bruggeling, A. S. G., “External Prestressing: A State of the Art,” External Prestressing in Bridges, SP-120, American Concrete Institute, Farmington Hills, MI, 1990, pp. 61-82.
3. Poston, R. W.; Frank, K. H.; and West, J. S., “Enduring Strength,” Civil Engineering (New York, N.Y.), V. 73, No. 9, Sept. 2003, pp. 58-63.
4. Podolny, W., “Corrosion of Prestressing Steels and Its Mitigation,” PCI Journal, V. 37, No. 5, 1992, pp. 34-55. doi: 10.15554/pcij.09011992.34.5510.15554/pcij.09011992.34.55 ↗
5. Woodard, R. J., “Collapse of a Segmental Post-Tensioned Concrete Bridge,” Transportation Research Record 1211, Transportation Research Board, National Research Council, Washington, DC, 1989, pp. 38-59.
6. ACI Committee 222, “Corrosion of Prestressing Steels (ACI 222.2R-01),” American Concrete Institute, Farmington Hills, MI, 2001, 42 pp.
7. Corven Engineering, “Mid-Bay Bridge Post-Tensioning Evaluation,” Final Report to Florida Department of Transportation, 2001.
8. Cavell, D. G., and Waldron, P., “A Residual Strength Model for Deteriorating Post-Tensioned Concrete Bridge,” Computers & Structures, V. 79, No. 4, 2001, pp. 361-373. doi: 10.1016/S0045-7949(00)00150-410.1016/S0045-7949(00)00150-4 ↗
9. Coronelli, D.; Castel, A.; Vu, N. A.; and François, R., “Corroded Post-Tensioned Beams with Bonded Tendons and Wire Failure,” Engineering Structures, V. 31, No. 8, 2009, pp. 1687-1697. doi: 10.1016/j.engstruct.2009.02.04310.1016/j.engstruct.2009.02.043 ↗
10. Lee, J., “Evaluation of External Post-Tensioned Tendon using Vibration Signatures,” PhD dissertation, University of Texas at Austin, Austin, TX, 2007.
11. McKinstry, C. A., “Frequency Response of Damaged External Post-Tensioned Tendons,” MS thesis, University of Texas at Austin, Austin, TX, 2010.
12. Wood, S. L.; McKinstry, C. A.; and Lee, J., “Residual Tensile Capacity of Grouted, Post-Tensioned Tendons,” ACI Structural Journal, V. 110, No. 6, Nov.-Dec. 2013, pp. 1099-1107.10.14359/51686164 ↗
13. Irvine, M. H., Cable Structures, Dover Publications, Mineola, New York, 1981, pp. 42-46.
14. Fang, Z., and Wang, J., “Practical Formula for Cable Tension Estimation by Vibration Method,” Journal of Bridge Engineering, ASCE, V. 17, No. 1, 2012, pp. 161-164. doi: 10.1061/(ASCE)BE.1943-5592.000020010.1061/(ASCE)BE.1943-5592.0000200 ↗
15. Zui, H.; Shinke, T.; and Namita, Y., “Practical Formulas for Estimation of Cable Tension by Vibration Method,” Journal of Structural Engineering, ASCE, V. 122, No. 6, 1996, pp. 651-656. doi: 10.1061/(ASCE)0733-9445(1996)122:6(651)10.1061/(ASCE)0733-9445(1996)122:6(651) ↗
16. ASTM A416/A416M-10, “Standard Specification for Steel Strand, Uncoated Seven-Wire for Prestressed Concrete,” ASTM International, West Conshohocken, PA, 2010, 5 pp.
17. ASTM C942-10, “Standard Test Method for Compressive Strength of Grouts for Preplaced-Aggregate Concrete in the Laboratory,” ASTM International, West Conshohocken, PA, 2010, 3 pp.