Abstract

This study demonstrates a highly sensitive humidity sensor based on treated multiwalled carbon nanotube (tr-MWCNT) and hydroxyethyl cellulose (HEC) composite films. Tr-MWCNTs are obtained by mixed acid treatment to enhance their hydrophilicity and improve their dispersion in distilled water. Compared to tr-MWCNT/silicone rubber (SR) composite film, the humidity sensitivity of tr-MWCNT/HEC film is much higher than tr-MWCNT/SR film with the same film thickness. The humidity sensing mechanisms of tr-MWCNT/HEC composites are explained by electron donation model and swelling mechanism. Speaking and blowing experiments were also carried out and the results show that tr-MWCNT/HEC composite film is sensitive to both speaking and blowing; furthermore, it can distinguish the small humidity level difference between speaking and blowing. Other sensing characteristics, including response and recovery time, stability, and temperature effect, are also investigated. The high humidity sensitivity of tr-MWCNT/HEC composite film indicates that it can be an excellent humidity sensitive material.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Carbon Nanotubes in Composites · Transition Metal Oxide Nanomaterials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. 10.1088/0957-4484/17/21/02610.1088/0957-4484/17/21/026 ↗
2. 10.1016/S0925-4005(01)00923-610.1016/S0925-4005(01)00923-6 ↗
3. 10.1166/sl.2005.00110.1166/sl.2005.001 ↗
4. 10.1016/j.physe.2010.06.01110.1016/j.physe.2010.06.011 ↗
5. 10.3390/s9090743110.3390/s90907431 ↗
6. 10.1016/S0925-4005(98)00255-X10.1016/S0925-4005(98)00255-X ↗
7. 10.1016/0250-6874(86)80055-510.1016/0250-6874(86)80055-5 ↗
8. 10.3390/s9030171410.3390/s90301714 ↗
9. 10.1016/j.snb.2005.12.04810.1016/j.snb.2005.12.048 ↗
10. 10.1016/j.snb.2012.12.10410.1016/j.snb.2012.12.104 ↗
11. 10.1111/j.1151-2916.1991.tb06911.x10.1111/j.1151-2916.1991.tb06911.x ↗
12. 10.1016/j.carbon.2011.02.02010.1016/j.carbon.2011.02.020 ↗
13. 10.1016/0925-4005(94)01268-M10.1016/0925-4005(94)01268-M ↗
14. 10.1016/j.snb.2007.03.01510.1016/j.snb.2007.03.015 ↗
15. 10.1016/j.synthmet.2012.09.01410.1016/j.synthmet.2012.09.014 ↗
16. 10.1016/S0925-4005(96)02019-910.1016/S0925-4005(96)02019-9 ↗
17. 10.1016/j.sse.2013.05.00110.1016/j.sse.2013.05.001 ↗
18. 10.1016/j.snb.2005.09.01910.1016/j.snb.2005.09.019 ↗
19. 10.1016/j.snb.2010.09.01610.1016/j.snb.2010.09.016 ↗
20. 10.1038/354056a010.1038/354056a0 ↗
21. Tapered plastic optical fiber coated with HEC/PVDF for measurement of relative humidity10.1109/JSEN.2013.2272329 ↗
22. 10.1016/j.snb.2004.04.10510.1016/j.snb.2004.04.105 ↗
23. 10.1016/j.snb.2009.11.04110.1016/j.snb.2009.11.041 ↗
24. 10.1016/j.snb.2006.12.03410.1016/j.snb.2006.12.034 ↗
25. 10.1016/j.snb.2003.12.04610.1016/j.snb.2003.12.046 ↗
26. 10.1016/j.carbon.2006.04.00510.1016/j.carbon.2006.04.005 ↗
27. 10.1088/0957-4484/24/8/08550110.1088/0957-4484/24/8/085501 ↗
28. 10.1103/PhysRevLett.87.15550210.1103/PhysRevLett.87.155502 ↗
29. 10.1016/j.sna.2004.11.03210.1016/j.sna.2004.11.032 ↗
30. 10.1088/0957-0233/14/6/30610.1088/0957-0233/14/6/306 ↗
31. 10.1016/S0925-4005(03)00213-210.1016/S0925-4005(03)00213-2 ↗
32. 10.1155/2011/70730310.1155/2011/707303 ↗
33. 10.1016/j.snb.2010.06.01010.1016/j.snb.2010.06.010 ↗
34. 10.1016/j.sna.2012.10.04110.1016/j.sna.2012.10.041 ↗
35. 14. Kim J.H. , Hong S.M. , Lee J.S. , Moon B.M. , and Kim K. : High sensitivity capacitive humidity sensor with a novel polyimide design fabricated by MEMS technology. In Nano/Micro Engineered and Molecular Systems, 2009. 4th IEEE International Conference on NEMS 2009, IEEE, pp. 703–706.10.1109/NEMS.2009.5068676 ↗