Compression Tests of Very Large Reinforced Concrete Pile Caps and Comparison with Predicted Strength
Source abstract
Abstract
First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Please select a country... Afghanistan Åland Islands Albania Algeria American Samoa Andorra Angola Anguilla Antarctica Antigua And Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Bahamas Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia Bonaire, Sint Eustatius and Saba Bosnia and Herzegovina Botswana Bouvet Island Brazil British Antarctic Territory British Indian Ocean Territory British Overseas Territory Brunei Darussalam Bulgaria Burkina Faso Burundi Cabo Verde Cambodia Cameroon Canada Cayman Islands Central African Republic Chad Chile China Christmas Island Cocos (Keeling) Islands Colombia Comoros Congo Congo, Democratic Republic of the Cook Islands Costa Rica Côte d'Ivoire Croatia Cuba Curaçao Cyprus Czech Republic Denmark Djibouti Dominica Dominican Republic Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Ethiopia Falkland Islands Faroe Islands Fiji Finland France French Guiana French Polynesia French Southern Territories Gabon Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guam Guatemala Guernsey Guinea Guinea-Bissau Guyana Haiti Heard Island and McDonald Islands Holy See (Vatican City) Honduras Hong Kong Hungary Iceland India Indonesia Iran, Islamic Republic of Iraq Ireland Isle of Man Israel Italy Jamaica Japan Jersey Jordan Kazakhstan Kenya Kiribati Korea (the Republic of) Korea, Democratic People's Republic of Kosovo, Republic of Kuwait Kyrgyzstan Lao People's Democratic Republic Latvia Lebanon Lesotho Liberia Libya Liechtenstein Lithuania Luxembourg Macau Macedonia, Former Yugoslav Republic of Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Martinique Mauritania Mauritius Mayotte Mexico Micronesia, Federated States of Moldova, Republic of Monaco Mongolia Montenegro Montserrat Morocco Mozambique Myanmar Namibia Nauru Nepal Netherlands New Caledonia New Zealand Nicaragua Niger Nigeria Niue Norfolk Island Northern Mariana Islands Norway Oman Pakistan Palau Palestine, State of Panama Papua New Guinea Paraguay Peru Philippines Pitcairn Poland Portugal Puerto Rico Qatar Réunion Romania Russian Federation Rwanda Saint Barthélemy Saint Kitts And Nevis Saint Lucia Saint Martin (French part) Saint Pierre and Miquelon Samoa San Marino Sao Tome And Principe Saudi Arabia Senegal Serbia Seychelles Sierra Leone Singapore Sint Maarten (Dutch part) Slovakia Slovenia Solomon Islands Somalia South Africa South Georgia South Sudan Spain Sri Lanka St Vincent And Grenadines St. Helena Ascensian and Tristan da Aunh Sudan Suriname Svalbard and Jan Mayen Swaziland Sweden Switzerland Syrian Arab Republic Taiwan Tajikistan Tanzania, United Republic of Thailand Timor-Leste Togo Tokelau Tonga Trinidad And Tobago Tunisia Turkey Turkmenistan Turks And Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States United States Minor Outlying Islands Uruguay Uzbekistan Vanuatu Venezuela Viet Nam Virgin Islands (British) Virgin Islands (U.S.) Wallis And Futuna Islands Western Sahara Yemen Zambia Zimbabwe Country/Territory is required
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Geotechnical Engineering and Underground Structures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Clarke, J. L., “Behaviour and Design of Pile Caps with Four Piles,” Cement and Concrete Association, London, UK, 1973.
2. Sabnis, G. M., and Gogate, A. B., “Investigation of Thick Slab (Pile Cap) Behavior,” ACI Journal Proceedings, V. 81, No. 1, Jan.-Feb. 1984, pp. 35-39.10.14359/10638 ↗
3. Schlaich, J.; Schafer, K.; and Jennewein, M., “Toward a Consistent Design of Structural Concrete,” PCI Journal, V. 32, No. 3, 1987, pp. 74-150. doi: 10.15554/pcij.05011987.74.15010.15554/pcij.05011987.74.150 ↗
4. Adebar, P.; Kuchma, D.; and Collins, M. P., “Strut-and-Tie Models for The Design of Pile Caps: An Experimental Study,” ACI Structural Journal, V. 87, No. 1, Jan.-Feb. 1990, pp. 81-92.10.14359/2945 ↗
5. Suzuki, K.; Otsuki, K.; and Tsubata, T., “Influence of Bar Arrangement on Ultimate Strength of Four-Pile Caps,” Transactions of the Japan Concrete Institute, V. 20, 1998, pp. 195-202.
6. Suzuki, K., and Otsuki, K., “Experimental Study on Corner Shear Failure of Pile Caps,” Transactions of the Japan Concrete Institute, V. 23, 2002, pp. 303-310.
7. Miguel, M. G.; Takeya, T.; and Giongo, J. S., “Structural Behaviour of Three-Pile Caps Subjected to Axial Compressive Loading,” Materials and Structures, V. 41, No. 1, 2007, pp. 85-98. doi: 10.1617/s11527-007-9221-510.1617/s11527-007-9221-5 ↗
8. Gu, Q.; Sun, C.; and Peng, S., “Experimental Study on Deep Four-Pile Caps with Different Reinforcement Layouts Based on 3D Strut-and-Tie Analogy,” Key Engineering Materials, V. 400, 2009, pp. 917-922.10.4028/www.scientific.net/KEM.400-402.917 ↗
9. Miguel-Tortola, L.; Pallarés, L.; and Miguel, P. F., “Punching Shear Failure in Three-Pile Caps: Influence of The Shear Span-Depth Ratio and Secondary Reinforcement,” Engineering Structures, V. 155, 2018, pp. 127-143. doi: 10.1016/j.engstruct.2017.10.07710.1016/j.engstruct.2017.10.077 ↗
10. Guo, H., “Investigation on Punching Behavior of Pile Cap under Column Reinforced by Section Steel Truss,” ACI Structural Journal, V. 115, No. 2, 2018, pp. 379-390. doi: 10.14359/5170094810.14359/51700948 ↗
11. Reineck, K.-H., and Novak, L. C., eds., Further Examples for The Design of Structural Concrete with Strut-and-Tie Models, SP-273, American Concrete Institute, Farmington Hills, MI, 2010, 288 pp.
12. Darwin, D.; Dolan, C. W.; and Nilson, A. H., Design of Concrete Structures, 15th edition, McGraw-Hill Education, New York, 2016, 786 pp.
13. ASTM C42/C42M-04, “Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete,” ASTM International, West Conshohocken, PA, 2004, 6 pp.
14. ASTM C39/C39M-05, “Test Method for Compressive Strength of Cylindrical Concrete Specimens,” ASTM International, West Conshohocken, PA, 2005, 7 pp.
15. ASTM C496/C496M-04e1, “Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens,” ASTM International, West Conshohocken, PA, 2004, 5 pp.
16. ASTM A615/A615M-05a, “Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement,” ASTM International, West Conshohocken, PA, 2005, 6 pp.
17. ASTM E8/E8-04, “Test Methods for Tension Testing of Metallic Materials,” ASTM International, West Conshohocken, PA, 2004, 24 pp.
18. Higgins, C., and Sorentino, A., “Report: VA Hospital Pile Cap Tests,” Oregon State University, Corvallis, OR, 2011, 98 pp. (available on request)
19. ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-02) and Commentary (ACI 318R-02),” American Concrete Institute, Farmington Hills, MI, 2002, 443 pp.
20. Reineck, K.-H., ed., Examples for the Design of Structural Concrete with Strut-and-Tie Models, SP-208, American Concrete Institute, Farmington Hills, MI, 2002, 242 pp.
21. ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19),” American Concrete Institute, Farmington Hills, MI, 2019, 623 pp.
22. Mitchell, D.; Collins, M. P.; Bhide, S. B.; and Rabbat, B., AASHTO LRFD Strut-and-Tie Model Design Examples, Portland Cement Association, Skokie, IL, 2004.
23. Boulifa, R.; Samai, M. L.; Benhassine, M. T.; and Tekkouk, A., “Predicting Strength Capacity of Three-Dimensional Concrete Struts in Pile Caps,” ACI Structural Journal, V. 118, No. 2, Mar. 2021, pp. 111-126.10.14359/51729344 ↗