journal article·1992-02

Fabrication of porous hydroxyapatite ceramics by microwave processing

Yi Fang, Dinesh K. Agrawal, Della M. Roy, Rustum Roy

Journal of Materials Research· Volume 7· Issue 2
Publisher page

Abstract

Porous hydroxyapatite ceramics with porosity up to 73% have been fabricated by microwave processing at 1150 to 1200 °C for 1 to 5 min. Various porosities in these ceramics have been obtained by using starting materials with different morphology, adjusting green density, changing sintering time and temperature, as well as optionally mixing ammonium carbonate in the hydroxyapatite powder during the consolidation process. Porosity, microstructure, and diametral tensile strength of the porous hydroxyapatite ceramics have been studied.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Advanced materials and composites · Surface Treatment and Coatings

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. 10.1007/BF0113201510.1007/BF01132015 ↗
2. 12. Fang Y. , Agrawal D. K. , and Roy D. M. , “Thermal Stability of Synthetic Hydroxyapatite” (in preparation).
3. 10. Fang Y. , Agrawal D. K. , Roy D. M. , and Roy R. , “Microwave Sintering of Hydroxyapatite Ceramics”, submitted to J. Am. Ceram. Soc. (under review).
4. Sutton · Am. Ceram. Soc. Bull. · 1989 · 68 · 376
5. 10.1016/0167-577X(86)90060-110.1016/0167-577X(86)90060-1 ↗
6. 10.1111/j.1151-2916.1985.tb10150.x10.1111/j.1151-2916.1985.tb10150.x ↗
7. 10.1038/247220a010.1038/247220a0 ↗
8. 10.1002/jbm.82009040610.1002/jbm.820090406 ↗
9. 11. Takata S. , Wakabayashi S. , Noma H. , and Waktsuki T. , “Porous Hydroxyapatite Material for Artificial Bone Substitute”, U. S. Patent No. 4629464 (December 16, 1986).
10. Lavernia · Am. Ceram. Soc. Bull. · 1991 · 70 · 95
11. 10.1126/science.176.4037.92210.1126/science.176.4037.922 ↗
12. 4. Roy D. M. , “Porous Biomaterials and Method of Making Same”, U. S. Patent No. 3929971 (1975).
13. 10.1016/S0022-5320(69)90043-410.1016/S0022-5320(69)90043-4 ↗
14. Eysel · “Topotactic Reaction of Aragonite to Hydroxyapatite”, Zeits. Kirst. · 1975 · 141 · 11
15. 14. Rudanick A. , Hunter A. R. , and Holden F. C. , “An Analysis of the Diametral-Compression Test”, Mat. Res. Standards, 283 (April 1963).