Magnetoresistive sensors and magnetic nanoparticles for biotechnology
Source abstract
Abstract
Magnetoresistive biosensors use a new detection method for molecular recognition reactions based on two recently developed techniques and devices: Magnetic markers and XMR sensors, where XMR means either giant magnetoresistance (GMR) or tunneling magnetoresistance (TMR). The markers are specifically attached to the target molecules, and their magnetic stray field is picked up by an embedded magnetoresistive sensor as a change of the electrical resistance. Compared to established, e.g., fluorescent, detection methods, magnetic biosensors have a number of advantages, including low molecular detection limits, flexibility, and the direct availability of an electronic signal suitable for further automated analysis. This makes them a promising choice for the detection units of future widespread and easy-to-use lab-on-a-chip systems or biochips. In this article, we discuss recent advances in this field and compare possible approaches toward single molecule detection.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced biosensing and bioanalysis techniques · Molecular Junctions and Nanostructures · Magnetic properties of thin films
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. 32. de Vries A. : High force magnetic tweezers for molecular manipulation inside living cells. Ph.D. Thesis, University of Twente, Enschede, The Netherlands (2004).
2. 10.1016/0021-9797(92)90163-G10.1016/0021-9797(92)90163-G ↗
3. 10.1007/978-1-4757-6482-610.1007/978-1-4757-6482-6 ↗
4. 26. Dynal Biotech: http://www.dynal.no.
5. 10.1016/j.bios.2003.11.00710.1016/j.bios.2003.11.007 ↗
6. Voet · 1994
7. 10.1016/j.jbiotec.2004.04.01810.1016/j.jbiotec.2004.04.018 ↗
8. 10.1126/science.287.5460.198910.1126/science.287.5460.1989 ↗
9. Sun · 1999 · 577 · 385
10. 10.1002/(SICI)1521-3757(19990614)111:12<1906::AID-ANGE1906>3.0.CO;2-010.1002/(SICI)1521-3757(19990614)111:12<1906::AID-ANGE1906>3.0.CO;2-0 ↗
11. 10.1126/science.105755310.1126/science.1057553 ↗
12. 10.1023/B:INMA.0000027598.65634.1910.1023/B:INMA.0000027598.65634.19 ↗
13. 10.1051/analusis:199927061710.1051/analusis:1999270617 ↗
14. Going their separate ways: A profile of products for cell separation
15. 10.1016/S0956-5663(99)00054-810.1016/S0956-5663(99)00054-8 ↗
16. 10.1016/S0304-8853(99)00335-210.1016/S0304-8853(99)00335-2 ↗
17. 9. See for example the website of the Robert Bosch GmbH, Stuttgart, Germany: http://rb-k.bosch.de/de/start/safety.html (Sept. 2005).
18. 10.1103/PhysRevLett.74.327310.1103/PhysRevLett.74.3273 ↗
19. 10.1016/0375-9601(75)90174-710.1016/0375-9601(75)90174-7 ↗
20. 10.1103/PhysRevLett.57.244210.1103/PhysRevLett.57.2442 ↗
21. 12. Motorola Inc., press release, October 2003, www.motorola.com/mediacenter/news/detail/0,3158_2591_23,00.html.
22. 10.1103/PhysRevLett.61.247210.1103/PhysRevLett.61.2472 ↗
23. 10.1143/PTP.16.4510.1143/PTP.16.45 ↗
24. 10.1146/annurev.matsci.30.1.54510.1146/annurev.matsci.30.1.545 ↗
25. 10.1147/rd.421.000310.1147/rd.421.0003 ↗
26. Magnetic properties of Cu–Mn alloys
27. 23. TeleChem International, Inc.: SuperClean substrate, http://www.arrayit.com (accessed September 2005).
28. 10.1016/S0956-5663(98)00037-210.1016/S0956-5663(98)00037-2 ↗
29. 10.1063/1.36480210.1063/1.364802 ↗
30. 10.1016/j.jbiotec.2004.04.01910.1016/j.jbiotec.2004.04.019 ↗
31. 10.1147/rd.451.004710.1147/rd.451.0047 ↗
32. 10.1103/PhysRev.96.9910.1103/PhysRev.96.99 ↗