journal article·2007-07

Degradation susceptibility of surgical magnesium alloy in artificial biological fluid containing albumin

Chenglong Liu, Yunchang Xin, Xiubo Tian, Paul K. Chu

Journal of Materials Research· Volume 22· Issue 7
Publisher page

Abstract

The objective of this study is to investigate the corrosion susceptibility of surgical AZ91 magnesium alloys in simulated body fluids (SBFs) consisting of bovine serum albumin (BSA) and acidic SBFs (pH 5) using electrochemical methods. The addition of BSA significantly moves the open-circuit potential toward a more positive value and suppresses the corrosion reaction. The corrosion resistance under the open-circuit conditions in the SBFs with 1 g/L BSA is approximately twice that in the SBFs. A higher BSA concentration decreases the corrosion susceptibility. In addition, the acidic SBF results in a higher alloy dissolution rate. The possible mechanisms are discussed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Study on the relationship between the corrosion interface structure and negative difference effect for pure magnesium.
2. 10.1016/0013-4686(92)87014-Q10.1016/0013-4686(92)87014-Q ↗
3. 10.1016/S0142-9612(98)00217-810.1016/S0142-9612(98)00217-8 ↗
4. 10.1016/j.msea.2003.08.06010.1016/j.msea.2003.08.060 ↗
5. Electrochemical studies of the adsorption behavior of bovine serum albumin on stainless steel.
6. 10.1016/S0010-938X(98)00078-X10.1016/S0010-938X(98)00078-X ↗
7. Effect of pH values on as-extruded magnesium alloy AM60.
8. Davis · 2003 · 16
9. Park · 1979 · 187–193
10. 10.1002/(SICI)1097-4636(19970905)36:3<387::AID-JBM13>3.0.CO;2-B10.1002/(SICI)1097-4636(19970905)36:3<387::AID-JBM13>3.0.CO;2-B ↗
11. 10.1016/j.electacta.2003.12.03610.1016/j.electacta.2003.12.036 ↗
12. 10.1016/j.biomaterials.2004.01.01510.1016/j.biomaterials.2004.01.015 ↗
13. Metal implants and surface reactions.
14. 10.1016/j.biomaterials.2004.09.04910.1016/j.biomaterials.2004.09.049 ↗
15. Surface charge of alumina and magnesia in aqueous media.10.1111/j.1151-2916.1964.tb13801.x ↗
16. 10.1016/j.biomaterials.2004.03.02510.1016/j.biomaterials.2004.03.025 ↗
17. 10.1016/j.corsci.2005.01.01010.1016/j.corsci.2005.01.010 ↗
18. 10.1002/adem.20050001310.1002/adem.200500013 ↗
19. 10.1016/j.biomaterials.2005.05.04710.1016/j.biomaterials.2005.05.047 ↗
20. 10.1002/jbm.82016020510.1002/jbm.820160205 ↗
21. Woodward · 1993 · 234
22. 10.1007/BF0234421310.1007/BF02344213 ↗
23. 10.1002/jbm.82014020810.1002/jbm.820140208 ↗
24. FTIR study on the precipitates of bovine serum albumin reacted with calcium hydroxyapatite.
25. 10.1016/j.corsci.2004.09.01810.1016/j.corsci.2004.09.018 ↗
26. 10.1016/S0142-9612(97)00153-110.1016/S0142-9612(97)00153-1 ↗
27. Corrosion behaviors and surface modification of magnesium alloys for biomaterial applications.
28. 10.1002/jbm.1032910.1002/jbm.10329 ↗
29. 10.1016/j.biomaterials.2005.07.03710.1016/j.biomaterials.2005.07.037 ↗
30. Cao · 2002 · 63–67
31. 10.1016/j.corsci.2006.05.03310.1016/j.corsci.2006.05.033 ↗
32. 10.1016/S0010-938X(96)00172-210.1016/S0010-938X(96)00172-2 ↗
33. 10.1016/S0010-938X(01)00092-010.1016/S0010-938X(01)00092-0 ↗