Seismic Behavior of Precast and Post-Tensioned Exterior Connections with Ductile Headed Rods
Source abstract
Abstract
First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Invalid Email Address
Only a short abstract or summary was supplied by the source.
Source: openalex_inverted_index · Quality: short
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. ACI Committee 318, 2019, “Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19),” American Concrete Institute, Farmington Hills, MI, 624 pp.
2. ACI Committee 374, 2013, “Guide for Testing Reinforced Concrete Structural Elements Under Slowly Applied Simulated Seismic Loads (ACI 374.2-13),” American Concrete Institute, Farmington Hills, MI, 18 pp.
3. ACI Committee 374, 2014, “Acceptance Criteria for Moment Frames Based on Structural Testing (ACI 374.1-05) and Commentary (Reapproved 2019),” American Concrete Institute, Farmington Hills, MI, 9 pp.
4. AIJ, 1999, “Design Guidelines for Earthquake Resistant Reinforced Concrete Buildings Based on Inelastic Displacement Concept,” Architectural Institute of Japan, Tokyo, Japan, pp. 138-192.
5. AIK, 2016, “Korean Building Code—Structural 2016,” Architectural Institute of Korea, Seoul, Korea.
6. AISC, 2016, “Specification for Structural Steel Buildings ANSI/AISC 360-16,” American Institute of Steel Construction, Chicago, IL.
7. Bhatt, P., and Kirk, D. W., 1985, “Tests on an Improved Beam Column Connection for Precast Concrete,” ACI Journal Proceedings, V. 82, No. 6, Nov.-Dec., pp. 834-843.10.14359/10395 ↗
8. Chang, B.; Hutchinson, T.; Wang, X.; and Englekirk, R., 2013, “Experimental Seismic Performance of Beam-Column Subassemblies Using Ductile Embeds,” Journal of Structural Engineering, ASCE, V. 139, No. 9, pp. 1555-1566. doi: 10.1061/(ASCE)ST.1943-541X.000062810.1061/(ASCE)ST.1943-541X.0000628 ↗
9. Cheok, G., and Lew, H. S., 1993a, “Model Precast Concrete Beam-to-Column Connections Subject to Cyclic Loading,” PCI Journal, V. 38, No. 4, pp. 80-92. doi: 10.15554/pcij.07011993.80.9210.15554/pcij.07011993.80.92 ↗
10. Cheok, G. S., and Lew, H. S., 1990, “Performance of 1/3-Scale Model Precast Concrete Beam-Column Connections Subjected to Cyclic Inelastic Loads,” NISTIR 4433, NIST, Gaithersburg, MD.10.6028/NIST.IR.4433 ↗
11. Cheok, G. S., and Lew, V. H. S., 1991, “Performance of 1/3-Scale Model Precast Concrete Beam-Column Connections Subjected to Cyclic Inelastic Loads-Report No. 2,” NISTIR 4589, NIST, Gaithersburg, MD.10.6028/NIST.IR.4589 ↗
12. Cheok, G. S., and Stone, W. C., 1993b, “Performance of 1/3-Scale Model Precast Concrete Beam-Column Connections Subjected to Cyclic Inelastic Loads-Report No. 3,” NISTIR 5246, NIST, Gaithersburg, MD.
13. Cheok, G. S., and Stone, W. C., 1994, “Performance of 1/3-Scale Model Precast Concrete Beam-Column Connections Subjected to Cyclic Inelastic Loads-Report No. 4,” NISTIR 5436, NIST, Gaithersburg, MD.
14. Englekirk, R. E., 2003, Seismic Design of Reinforced and Precast Concrete Buildings, John Wiley & Sons, New York.
15. fib, 2013, “fib Model Code for Concrete Structures 2010,” International Federation for Structural Concrete (fib), Lausanne, Switzerland, 434 pp.10.1002/9783433604090 ↗
16. Hajdukiewicz, M.; Goggins, J.; de la Torre, O.; Holleran, D.; and Keane, M. M., 2019, “An Automated Standard-Based Life Cycle Quality Inspection Methodology for Smart Precast Concrete Solutions in Buildings,” Journal of Structural Integrity and Maintenance, V. 4, No. 3, pp. 123-134. doi: 10.1080/24705314.2019.162745410.1080/24705314.2019.1627454 ↗
17. Ibrahim Ary, M. and Kang, T. H.-K., 2012, “Shear-Strengthening of Reinforced & Prestressed Concrete Beams Using FRP: Part I - Review of Previous Research,” International Journal of Concrete Structures and Materials, V. 6, No. 110.1007/s40069-012-0004-1 ↗
18. Joint ACI-ASCE Committee 352, 2002, “Recommendations for Design of Beam-Column Connections in Monolithic Reinforced Concrete Structures (ACI 352R-02, Reapproved 2010),” American Concrete Institute, Farmington Hills, MI, 38 pp.
19. Kang, T. H.-K., and Ibrahim Ary, M., 2012, “Shear-Strengthening of Reinforced & Prestressed Concrete Beams Using FRP: Part II - Experimental Investigation,” International Journal of Concrete Structures and Materials, V. 6, No. 110.1007/s40069-012-0005-0 ↗
20. Kim, J., 2000, “Final Report on Testing of Hybrid Frame Corner Beam-Column Subassembly with Continuous Post-Tensioning Steel,” Structural Research Laboratory, University of Washington, Seattle, WA.
21. Kim, J., and LaFave, J. M., 2007, “Key Influence Parameters for the Joint Shear Behaviour of Reinforced Concrete (RC) Beam-Column Connections,” Engineering Structures, V. 29, No. 10, pp. 2523-2539. doi: 10.1016/j.engstruct.2006.12.01210.1016/j.engstruct.2006.12.012 ↗
22. Kim, J., and LaFave, J. M., 2012, “A Simplified Approach to Joint Shear Behavior Prediction of RC Beam-Column Connections,” Earthquake Spectra, V. 28, No. 3, pp. 1071-1096. doi: 10.1193/1.400006410.1193/1.4000064 ↗
23. Kim, J.; Stanton, J.; MacRae, G.; Day, S.; and Sugata, M., 2004, “Cyclic Load Testing of Precast Hybrid Frame Connections,” Proceedings, Thirteenth World Conference on Earthquake Engineering, Paper No. 1671, Vancouver, BC, Canada.
24. KSSC, 2009, “Fabrication Guide for Structural Joints Using High-Strength Bolts (KBC-09),” Korean Society of Steel Construction, Seoul, Korea, 111 pp. (in Korean)
25. Lim, W.-Y.; Kang, T. H.-K.; and Hong, S.-G., 2018, “Effect of Reinforcement Details on Seismic Behavior of Precast Concrete Wall-Steel Coupling Beam Systems,” ACI Structural Journal, V. 115, No. 6, Nov.-Dec., pp. 1751-1763. doi: 10.14359/5170241410.14359/51702414 ↗
26. Martin, L. D., and Korkosz, W. J., 1982, “Connections for Precast Prestressed Concrete Buildings, Including Earthquake Resistance,” Technical Report No. 2, Precast/Prestressed Concrete Institute, Chicago, IL.10.15554/TR-2-82 ↗
27. Nakaki, S. D., and Englekirk, R. E., 1991, “PRESSS Industry Seismic Workshops: Concept Development,” PCI Journal, V. 36, No. 6, pp. 54-61. doi: 10.15554/pcij.09011991.54.6110.15554/pcij.09011991.54.61 ↗
28. Nakaki, S. D.; Englekirk, R. E.; and Plaehn, J. L., 1994, “Ductile Connectors for a Precast Concrete Frame,” PCI Journal, V. 39, No. 5, pp. 46-59. doi: 10.15554/pcij.09011994.46.5910.15554/pcij.09011994.46.59 ↗
29. Palmieri, L.; Saqan, E.; French, C.; and Kreger, M., 1996, “Ductile Connections for Precast Concrete Frame Systems,” Proceedings Mete A. Sozen Symposium, SP-162, J. K. Wight and M. E. Kreger, eds., American Concrete Institute, Farmington Hills, MI, pp. 315-355.
30. Park, R., and Paulay, T., 1975, “Reinforced Concrete Structures, John Wiley & Sons, New York, 769 pp.10.1002/9780470172834 ↗
31. Park, M.-K.; Lee, D. H.; Han, S.-J.; and Kim, K. S., 2019, “Web-Shear Capacity of Thick Precast Prestressed Hollow-Core Slab Units Produced by Extrusion Method,” International Journal of Concrete Structures and Materials, V. 19, No. 7.10.1186/s40069-018-0288-x ↗
32. Pillai, S. U., and Kirk, D. W., 1981, “Ductile Beam-Column Connection in Precast Concrete,” ACI Journal Proceedings, V. 78, No. 6, Nov.-Dec., pp. 480-487.10.14359/10926 ↗
33. Probst, A. D.; Kang, T. H.-K.; Ramseyer, C.; and Kim, U., 2010, “Composite Flexural Behavior of Full-Scale Concrete-Filled Tubes without Axial Loads,” Journal of Structural Engineering, ASCE, V. 136, No. 11, pp. 1401-1412. doi: 10.1061/(ASCE)ST.1943-541X.000024110.1061/(ASCE)ST.1943-541X.0000241 ↗