Drift Capacity Design of Shear Walls Reinforced with Glass Fiber-Reinforced Polymer Bars
Source abstract
Abstract
First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Invalid Email Address
Only a short abstract or summary was supplied by the source.
Source: openalex_inverted_index · Quality: short
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Engineering and Vibration Analysis · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. ACI Committee 318, 2008, “Building Code Requirements for Structural Concrete and Commentary (ACI 318-08),” American Concrete Institute, Farmington Hills, MI, 473 pp.
2. ACI Committee 440, 2006, “Guide for the Design and Construction of Concrete Reinforced with FRP Bars (ACI 440.1R-06),” American Concrete Institute, Farmington Hills, MI, 44 pp.
3. Adebar, P., 2006, “Drift Capacity of Walls Accounting for Shear: The 2004 Canadian Code Provisions,”Deformation Capacity and Shear Strength of Reinforced Concrete Members under Cyclic Loading, SP-236, A. Matamoros and K. Elwood, eds., American Concrete Institute, Farmington Hills, MI, pp. 151-170.
4. Ductility of Concrete Walls: The Canadian Seismic Design Provision 1984 to 200410.1139/l05-070 ↗
5. ASCE 7, 2008, “Minimum Design Loads for Buildings and Other Structures.” American Society of Civil Engineering, Reston, VA.
6. Plastic Hinge Analysis10.1061/(ASCE)0733-9445(2001)127:9(1092) ↗
7. Shear Deformations of Slender Reinforced Concrete Walls under Seismic Loading
8. Plastic Hinge Lengths in High-rise Concrete Shear Walls
9. Method for the Design of Light Gauge Steel Frame/Wood Panel Shear Walls
10. CAN/CSA A23, 3-04, 2004, “Design of Concrete Structures,” Canadian Standards Association, Mississauga, ON, Canada, 240 pp.
11. CAN/CSA S806-12, 2012, “Design and Construction of Building Components with Fiber-Reinforced Polymers,” Canadian Standards Association, Mississauga, ON, Canada, 208 pp.
12. Low-Rise Shear Wall Ultimate Drift Limit10.1193/1.1585792 ↗
13. FEMA, 356, 2000, “Prestandard and Commentary for the Seismic Rehabilitation of Buildings.” Federal Emergency Management Agency, Washington, DC, 518 pp.
14. Performance of Buildings with Shear Walls in Earthquakes of the Last Thirty Years10.15554/pcij.05011995.62.80 ↗
15. Uniform Building Code (UBC), 1988,International Conference of Building Officials, Whittier, CA, 709 pp.
16. Kessler, S., 2010, “A Study of the Seismic Response Modification Factor for Log Shear Walls.” MSc thesis, Kansas State University, Manhattan, KS, 113 pp.
17. Seismic Force Modification Factors for the Proposed 2005 Edition of the National Building Code of Canada10.1139/l02-111 ↗
18. Cyclic Load Behavior of GFRP-Reinforced Concrete Shear Walls10.1061/(ASCE)CC.1943-5614.0000393 ↗
19. Munoz, W.; Salenikovich, A.; Mohammad, M.; and Quenneville, P., 2008, “Determination of Yield Point and Ductility of Timber Assemblies: in Search for a Harmonised Approach,”Proceedings of Meeting 41 of CIB-W18, St. Andrews, NB, Canada.
20. National Building Code of Canada (NBCC), 2010, Canadian Commission on Building and Fire Codes, National Research Council of Canada, Montreal, QC, Canada.
21. Paulay, T., and Priestley, M. J. N., 1995,Seismic Design of Reinforced Concrete and Masonry Buildings, John Wiley & Sons, Inc., New York, 735 pp.
22. Priestley, M.; Seible, F.; and Calvi, G., 1996,Seismic Design and Retrofit of Bridges, John Wiley & Sons, Inc, New York.10.1002/9780470172858 ↗
23. Rogers, C. A.; Balh, N.; Ong-Tone, C.; Shamim, I.; and DaBreo, J., 2011, “Development of Seismic Design Provisions for Steel Sheet Sheathed Shear Walls,”Proceedings of the Structures Congress, ASCE, Las Vegas, NV, pp. 676-687.10.1061/41171(401)59 ↗
24. Behavior of Fully Grouted Reinforced Concrete Masonry Shear Walls Failing in Flexure: Analysis10.1016/j.engstruct.2009.03.006 ↗
25. Seismic Response Modification Factors for Reinforced Masonry Structural Walls10.1061/(ASCE)CF.1943-5509.0000144 ↗
26. Flexural Drift Capacity of Reinforced Concrete Wall with Limited Confinement
27. Concrete Columns Reinforced Longitudinally and Transversally with Glass Fiber-Reinforced Polymer Bars
28. The Chile Earthquake of March 3, 1985—Performance of Structures