journal article·2007Open access

Reliability of Transfer Length Estimation from Strand End Slip

Authors not provided

ACI Structural Journal· Volume 104· Issue 4

Abstract

[EN] An experimental program on twelve series of specimens with different embedment lengths to determine the transfer length was conducted. Transfer length test results of seven-wire strand on twelve different concrete mixtures were analyzed. A testing technique based on the analysis of bond behaviour by means of measuring the force supported by the tendon has been used. The specimens had been instrumented with slip measurement devices at each end of the specimen. A sequence of slip values at each end of the specimen after release versus the embedment length has been analyzed. The expressions relating the transfer length to the tendon end slip are presented. A value of Guyon's factor for tendon stress distribution shape has been obtained. Two criteria to determine the transfer length from the slip sequences at both ends of the specimens have been analyzed.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Geotechnical Engineering and Underground Structures · Concrete Corrosion and Durability · Mechanical stress and fatigue analysis