journal article·2015-04

Modeling the Normal Spectral Emissivity of Aluminum 1060 at 800-910 K During the Growth of Oxide Layer

Deheng Shi, Fenghui Zou, Zunlue Zhu, Jinfeng Sun

Publisher page

Abstract

This work strives to model the normal spectral emissivity of aluminum 1060 during the growth of oxide layer in air over the temperatures ranging from 800 to 910 K. For this reason, the normal spectral emissivity of aluminum 1060 has been measured over a 6 h heating period at a definite temperature. In our experiment, the radiance coming from the specimen is received by an InGaAs photodiode detector, which works at 1.5 μm with the bandwidth of 20 nm. The temperature of specimen surface is measured by averaging the two platinum-rhodium thermocouples, which are symmetrically welded in the front surface of specimen near the measuring area viewed by the detector. The strong oscillations of normal spectral emissivity have been observed and discussed, which are affirmed to be connected with the thickness of oxide layer on the specimen surface, and originate from the interference effect between the radiation coming from the oxide layer on the specimen surface and the radiation stemming from the substrate. The uncertainty of normal spectral emissivity contributed only by the surface oxidization is about 4.6-10.6%, and the corresponding uncertainty of temperature contributed only by the surface oxidization is about 3.5-8.4 K. The analytical model between the normal spectral emissivity and the heating time is evaluated at a definite temperature. A simple functional form with the exponential and logarithmic functions can be employed to reproduce well the variation of normal spectral emissivity with the heating time at a definite temperature, including the reproduction of strong oscillations.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Calibration and Measurement Techniques · Advanced Sensor Technologies Research · Thermography and Photoacoustic Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. C.-D. Wen and I. Mudawar, Modeling the Effects of Surface Roughness on the Emissivity of Aluminum Alloys, Int. J. Heat Mass Transf., 2006, 49, p 4279–428910.1016/j.ijheatmasstransfer.2006.04.037 ↗
2. C.-D. Wen and T.-Y. Chai, Experimental Investigation of Emissivity of Aluminum Alloys and Application of Multispectral Radiation Thermometry, Appl. Therm. Eng., 2011, 31, p 2414–242110.1016/j.applthermaleng.2011.04.005 ↗
3. C.-D. Wen and I. Mudawar, Emissivity Characteristics of Roughened Aluminum Alloy Surfaces and Assessment of Multispectral Radiation Thermometry (MRT) Emissivity Models, Int. J. Heat Mass Transf., 2004, 47, p 3591–360510.1016/j.ijheatmasstransfer.2004.04.025 ↗
4. C.-D. Wen and I. Mudawar, Emissivity Characteristics of Polished Aluminum Alloy Surfaces and Assessment of Multispectral Radiation Thermometry (MRT) Emissivity Models, Int. J. Heat Mass Transf., 2005, 48, p 1316–132910.1016/j.ijheatmasstransfer.2004.10.003 ↗
5. C.-D. Wen and I. Mudawar, Mathematical Determination of Emissivity and Surface Temperature of Aluminum Alloys Using Multispectral Radiation Thermometry, Int. Commun. Heat Mass Transf., 2006, 33, p 1063–107010.1016/j.icheatmasstransfer.2006.05.010 ↗
6. C.-D. Wen and T.-Y. Chai, Examination of Multispectral Radiation Thermometry Using Linear and Log-Linear Emissivity Models for Aluminum Alloys, Heat Mass Transf., 2011, 47, p 847–85610.1007/s00231-011-0769-9 ↗
7. T. Furukawa and T. Iuchi, Experimental Apparatus for Radiometric Emissivity Measurements of Metals, Rev. Sci. Instrum., 2000, 71, p 2843–284710.1063/1.1150701 ↗
8. T. Iuchi, Modeling of Emissivities of Metals and Their Behaviors during the Growth of an Oxide Film, Temperature: Its Measurement and Control in Science and Technology, AIP Conf. Proc. 684, Ed. D.C. Ripple (AIP, Melville, NY), 2003, 7, p 717–72210.1063/1.1627212 ↗
9. J. Pujana, L. del Campo, R.B. Pérez-Sáez, M.J. Tello, I. Gallego, and P.J. Arrazola, Radiation Thermometry Applied to Temperature Measurement in the Cutting Process, Meas. Sci. Technol., 2007, 18, p 3409–341610.1088/0957-0233/18/11/022 ↗
10. C.-D. Wen, Investigation of Steel Emissivity Behaviors: Examination of Multispectral Radiation Thermometry (MRT) Emissivity Models, Int. J. Heat Mass Transf., 2010, 53, p 2035–204310.1016/j.ijheatmasstransfer.2009.12.053 ↗
11. C.-D. Wen, Study of Steel Emissivity Characteristics and Application of Multispectral Radiation Thermometry (MRT), J. Mater. Eng. Perform., 2011, 20, p 289–29710.1007/s11665-010-9666-5 ↗
12. Z.M. Zhang, B.K. Tsai, and G. Machin, Ed., Radiometric Temperature Measurements: I. Fundamentals, Academic Press (an Imprint of Elsevier), Amsterdam, 2009
13. Z.M. Zhang, B.K. Tsai, and G. Machin, Ed., Radiometric Temperature Measurements: II. Applications, Academic Press (an Imprint of Elsevier), Amsterdam, 2009
14. L. del Campo, R.B. Pérez-Sáez, and M.J. Tello, Iron Oxidation Kinetics Study by Using Infrared Spectral Emissivity Measurements below 570 °C, Corros. Sci., 2008, 50, p 194–19910.1016/j.corsci.2007.05.029 ↗
15. L. del Campo, R.B. Pérez-Sáez, L. González-Fernández, and M.J. Tello, Kinetics Inversion in Isothermal Oxidation of Uncoated WC-Based Carbides Between 450 and 800°C, Corros. Sci., 2009, 51, p 707–71210.1016/j.corsci.2008.12.022 ↗