Cores at Early Ages for In-Place Concrete Acceptance
Source abstract
Abstract
First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Invalid Email Address
Only a short abstract or summary was supplied by the source.
Source: openalex_inverted_index · Quality: short
Research context
OpenAlex topics: Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Ariöz, Ö.; Tuncan, M.; Ramyar, K.; and Tuncan, A., “A Comparative Study on the Interpretation of Concrete Core Strength Results,” Magazine of Concrete Research, V. 58, No. 2, 2006, pp. 117-122. doi: 10.1680/macr.2006.58.2.11710.1680/macr.2006.58.2.117 ↗
2. Szypula, A., and Grossman, J. S., “Cylinder versus Core Strength,” Concrete International, V. 12, No. 2, Feb. 1990, pp. 55-61.
3. SSP 999F31, “Construction Specification for Non-Prestressed Precast Concrete Bridge Elements,” Ontario Ministry of Transportation, Toronto, ON, Canada, 2016, 19 pp.
4. OPSS, PROV 909, “Construction Specification for Prestressed Concrete – Precast Girder,” Ontario Ministry of Transportation, Toronto, ON, Canada, 2016, 32 pp.
5. ASTM C42/42M-13, “Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete,” ASTM International, West Conshohocken, PA, 2013, 7 pp.
6. ASTM C39/C39M-18, “Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens,” ASTM International, West Conshohocken, PA, 2018, 8 pp.
7. ASTM C1202-12, “Standard Test Method for Electrical Indication of Concrete’s Ability to Resist Chloride Ion Penetration,” ASTM International, West Conshohocken, PA, 2012, 8 pp.
8. ASTM C1760-12, “Standard Test Method for Bulk Electrical Conductivity of Hardened Concrete,” ASTM International, West Conshohocken, PA, 2012, 5 pp.
9. Layssi, H.; Ghods, P.; Alizadeh, A. R.; and Salehi, M., “Electrical Resistivity of Concrete,” Concrete International, V. 37, No. 5, May 2015, pp. 41-46.
10. Goto, S., and Roy, D. M., “The Effect of w/c Ratio and Curing Temperature on the Permeability of Hardened Cement Paste,” Cement and Concrete Research, V. 11, No. 4, 1981, pp. 575-579. doi: 10.1016/0008-8846(81)90087-910.1016/0008-8846(81)90087-9 ↗
11. Shideler, J. J., and Chamberlin, W. H., “Early Strength of Concrete as Affected by Steam Curing Temperatures,” ACI Journal Proceedings, V. 46, No. 12, Dec. 1949, pp. 273-282.10.14359/12057 ↗
12. Nokken, M. R., and Hooton, R. D., “Electrical Conductivity Testing,” Concrete International, V. 28, No. 10, Oct. 2006, pp. 58-63.
13. Hassan, K. E.; Cabrera, J. G.; and Maliehe, R. S., “The Effect of Mineral Admixtures on the Properties of High-Performance Concrete,” Cement and Concrete Composites, V. 22, No. 4, pp. 2000, 267-271.10.1016/S0958-9465(00)00031-7 ↗
14. Suprenant, B., “An Introduction to Concrete Core Testing,” Civil Engineering for Practicing and Design Engineers, V. 4, 1985, pp. 607-615.
15. Bartlett, F. M., and MacGregor, J. G., “Assessment of Concrete Strength in Existing Structures,” Department of Civil Engineering, University of Alberta, Edmonton, AB, Canada, 1994, 321 pp.
16. Bloem, D. L., “Concrete Strength Measurement—Cores Versus Cylinders,” Proceedings, American Society for Testing and Materials, V. 65, 1965, pp. 668-696.
17. Khoury, S.; Aliabdo, A. A.-H.; and Ghazy, A., “Reliability of Core Test—Critical Assessment and Proposed New Approach,” Alexandria Engineering Journal, V. 53, No. 1, 2014, pp. 169-184. doi: 10.1016/j.aej.2013.12.00510.1016/j.aej.2013.12.005 ↗
18. Bartlett, F. M., and MacGregor, J. G., “Effect of Moisture Condition on Concrete Core Strengths,” ACI Materials Journal, V. 91, No. 3, May-June 1994, pp. 227-236.10.14359/4328 ↗