Nitinol, a group of nearly equiatomic Ni-Ti alloys, steadily conquers new areas of application. Because of the need to keep a low profile of miniature implant devices, and considering the lack of compatibility between Nitinol superelasticity and the mechanical properties of traditional coatings, bare surfaces are of interest. In this article, an overview of our studies of bare Nitinol surfaces is presented, and the performance of coated surfaces is outlined. Together dense and porous Nitinol offer a wide array of surface topographies, suitable for attachment and migration of biological cells and tissue ingrowth. Native Nitinol surface oxides vary from amorphous to crystalline and exhibit semiconducting properties associated with better blood compatibility. Nitinol surfaces are analyzed with regard to high and lasting nickel release in vitro. Surface oxide thickness and Nitinol intermetallic particulates are discussed in relation to corrosion resistance and mechanical performance of the material.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Bone Tissue Engineering Materials · Ferroelectric and Piezoelectric Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. S. Shabalovskaya (1996), On the nature of biocompatibility and medical applications of NiTi shape memory alloys, Bio Med Mater Eng, 6, 1996, p. 267-290.10.3233/BME-1996-6405 ↗
2. S. Shabalovskaya and J. Van Humbeeck, Biocompatibility of Nitinol for Medical Applications, Shape Memory Alloys for Medical Applications, Chap. 9, 1st ed., T. Yoneyama and S. Miyazaki, Ed., Woodhead Publishing Limited, Cambridge, 200810.1201/9781439829219.ch9 ↗
3. O. Cisse, O. Savagodo, M. Wu, L. Yahia, Effect of surface treatment of NiTi alloy on its corrosion behavior in Hank’s solution, J Biomed Mater Res, 61, 2002, p. 339–345.10.1002/jbm.10114 ↗
4. B. Clarke, W. Carroll, Y. Rochev, M. Hynes, D. Bradley, D. Plumley, Influence of Nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release, J Biomed Mater Res, 79A, 2006, p. 61–70.10.1002/jbm.a.30720 ↗
5. B. Wertman, B. Azabal, M. Riedl, J. Tobis, Adverse events associated with nickel allergy in patients undergoing percutaneous Atrial Seoptal Defect of Paten Foramen Ovale closure, J Am Coll Cardiol, 47, 2006, 1226–1227. doi: 10.1016/j.jacc.2005.12.017 .10.1016/j.jacc.2005.12.017 ↗
6. S. Shabalovskaya, Surface, corrosion and biocompatibility aspects of Nitinol as an implant material, Bio Med Mater Eng, 12, 2002, p. 69–109.
7. S. Shabalovskaya, J. Anderegg, J. Van Humbeeck, Critical overview of Nitinol surfaces and their modifications for medical applications, Acta Biomater, 4, 2008, p. 447-467.10.1016/j.actbio.2008.01.013 ↗
8. S. Shabalovskaya, G. Rondelli, A. Undisz, J. Anderegg, D. Burleigh, and M. Rettenmayr, The Electrochemical Characteristics of Native Nitinol Surfaces, Biomaterials, 2009, 30, p 3662–3671. doi: 10.1016/j.biomaterials.2009.03.03410.1016/j.biomaterials.2009.03.034 ↗
9. S. Barison, S. Cattarin, S. Daolio, M. Musiani, A. Tuissi, Characterization of surface oxidation of nickel-titanium alloy by ion-beam and electrochemical techniques. Electrochemica Acta 50, 2004, p. 11–18.10.1016/j.electacta.2004.07.007 ↗
10. S. Shabalovskaya, He Tian, J. Anderegg, D. Schryvers, W. Carroll, J. Van Humbeeck, The influence of surface oxides on the distribution and release of nickel from Nitinol wires, Biomaterials, 30, 2009, p. 468–477.10.1016/j.biomaterials.2008.10.014 ↗
11. V. Chuprina, Examination of the Process of Oxidation of Titanium Nickelide, Poroshkovaya Metall. (Eng.), 1989, 316(4), p 310–313 and 1989, 318(6), p 57–6110.1007/BF00797991 ↗
12. C. Chan, C. Tringwell, T. Duerig, Oxidation of NiTi alloy, Surface and Interface Analysis 15, 1990, p. 349–354.10.1002/sia.740150602 ↗
13. L. Zhu, J. Fino, and A. Pelton, Oxidation of Nitinol, Proceedings of the Conference on Shape Memory and Superelastic Technologies (SMST), Asilomar, A. Pelton and T. Duerig, Ed., 2003, p 357–365
14. D. Bogdanski, “Untersuchungen zur Biocompatibilität and Biofunktionalität von Implantatmaterialien am Beispiel von Nickel-Titan-Formgedächtnislegierungen,” Ph.D. Thesis, Ruhr-Universität Bochum, Germany, 2005
15. C. Heintz, G. Riepe, L. Birken, E. Kaiser, N. Chakfe, M. Morlock, G. Delling, H. Imig, Corroded Nitinol wires in explanted aortic endografts: An important mechanism or failure? J Endovasc Ther, 8, 2001, p. 248–253.10.1177/152660280100800303 ↗
16. C. Trepanier, L. Zhu, J. Fino, and A. Pelton, Corrosion Resistance of Oxidized Nitinol, Oxidation of Nitinol, Proceedings of the SMST, Asilomar, A. Pelton and T. Duerig, Ed., 2003, p 367–375
17. A. Undisz, F. Schrempel, W. Wesch, M. Rettenmayr, In situ observation of surface oxide layers on medical NiTi alloy during straining, J Biomed Mater Res, 88A, 2009, p. 1000–1009.10.1002/jbm.a.31946 ↗
18. S. Shabalovskaya, J. Anderegg, G. Rondelli, and J. Xiong, The Effect of Surface Particulates on the Corrosion Resistance of Nitinol Wire, Proceedings of the SMST, Asilomar, A. Pelton and T. Duerig, Ed., 2003, p 399–408
19. S. Shabalovskaya, J. Anderegg, J. Van Humbeeck, Recent observations of particulates in Nitinol, Mater Sc Eng, A481-482, 2008, p. 431–436.10.1016/j.msea.2007.01.177 ↗
20. T. Jacobs, J. Won, C. Gravereaux, P. Faries, N. Morryssey, V. Teodorescu, L. Hollier, M. Marin, Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices, J Vasc Surg, 37, 2003, p. 16–26.10.1067/mva.2003.58 ↗
21. Morita M, Hashimoto T, Yamauchi K, Suto Y, Homma T, Kimura Y. Evaluation of biocompatibility for titanium-nickel shape memory alloys in vivo and in vitro environments. Mater Trans 48, 2007, p. 352–360.10.2320/matertrans.48.352 ↗
22. C. Heßing, J. Frenzel, M. Pohl, S. Shabalovskaya, Effect of martensitic transformation on the performance of coated NiTi surfaces, Mater Sci Eng, A 486, 2008, p. 461–469.10.1016/j.msea.2007.09.029 ↗
23. G. Tepe, J. Schmehl, H. Wendel, S. Schaffner, S. Heller, M. Gianotti, C. Claussen, S. Duda, Reduced thrombogenicity of Nitinol stents - In vitro evaluation of different surface modifications and coatings, Biomaterials, 27, 2006, p. 643–650.10.1016/j.biomaterials.2005.06.004 ↗
24. T. Peitsch, A. Klocke, B. Kahl-Nieke, O. Prymak, M. Epple, The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation, J Biomed Mater Res, 82A, 2007, p. 731–739.10.1002/jbm.a.31097 ↗