Electrode Configurations for Resistivity Measurements on Concrete
Source abstract
Abstract
In this study, two- and four-electrode arrangements were used to evaluate the electrical resistance (hence resistivity) of saturated concrete specimens using both embedded rod-electrodes, external plate-electrodes, and combinations thereof Measurements were obtained mainly at a fixed frequency of 1 kHz. It is shown that the two-electrode external plate measurement system gave higher resistivity values than the four-electrode system; however studying the electrical response in terms of complex impedance, over the frequency range 1 to 10 MHz, revealed that the sponge-contacting system used in the two-electrode method introduced a spurious resistance attributed to the sponge-sample interface.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.