Abstract
Titanium and its alloys are widely used as implant materials due to their exceptional biocompatibility, light weight, good mechanical properties and high corrosion resistance. Despite remarkable corrosion resistance of titanium alloys, loosening of implants occurs after long-term use due to metallic ions produced during corrosion. This work focuses on corrosion behavior of Ti-6Al-4 V samples fabricated by the laser-powder bed fusion (L-PBF) process and also after heat treatment at 800 °C for 1.5 h and subsequent cooling in furnace. While there was martensitic (α′) phase in the as-built condition, there was dual phase microstructure of α + β phase after heat treatment. Corrosion testing was carried out in Ringer’s solution. Electrochemical impedance spectroscopy (EIS) revealed that after heat treatment, the charge-transfer resistance increased from 98096 to 310130 Ω.cm2, due to increase in the oxide layer thickness. The Tafel plot showed a noticeable reduction in corrosion of the heat-treated samples. It was observed by x-ray photoelectron spectroscopy that there was an increase in atomic percentage of Ti, Al, and Oxygen, and decrease in their full width at half maximum, following heat treatment. The ductility of the heat-treated samples under compression was more than double than that of the as-built sample. While the yield strength in compression of heat-treated samples was lower, the compressive strength was higher than that of the as-built sample. Thus, L-PBF process combined with heat treatment can be utilized to fabricate high corrosion resistant Ti-6Al-4 V bioimplants.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Additive Manufacturing Materials and Processes · Titanium Alloys Microstructure and Properties · High Entropy Alloys Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. M. Salmi, Additive Manufacturing Processes in Medical Applications, Materials, 2021, 14(1), p 191.10.3390/ma14010191 ↗
2. F.J.M. Rivera and A.J.R. Arciniegas, Additive Manufacturing Methods: Techniques, Materials, and Closed-Loop Control Applications, Int. J. Adv. Manufact. Technol., 2020, 109(1), p 17–31.10.1007/s00170-020-05663-6 ↗
3. P.K. Singh, S. Kumar and P.K. Jain, Additive Manufacturing Technologies and Post-processing, Design Optimization, and Material Considerations for Reliable Printing, Nanotechn. Based Addit. Manufact. Product Des. Propert. Appl., 2023, 1, p 27–52.
4. S. Maher, A.R. Wijenayaka, L. Lima-Marques, D. Yang, G.J. Atkins and D. Losic, Advancing of Additive-Manufactured Titanium Implants with Bioinspired Micro-to Nanotopographies, ACS Biomater. Sci. Eng., 2021, 7(2), p 441–450.10.1021/acsbiomaterials.0c01210 ↗
5. M. Luqman, A.H. Seikh, A. Sarkar, S.A. Ragab, J.A. Mohammed, M.F. Ijaz et al., A Comparative Study of the Electrochemical Behavior of α and β Phase Ti6Al4V Alloy in Ringer’s Solution, Crystals, 2020, 10(3), p 190.10.3390/cryst10030190 ↗
6. H.M. Hamza, K.M. Deen and W. Haider, Microstructural Examination and Corrosion Behavior of Selective Laser Melted and Conventionally Manufactured Ti6Al4V for Dental Applications, Mater. Sci. Eng. C, 2020, 113, p 110980.10.1016/j.msec.2020.110980 ↗
7. Y. Li, C. Yang, H. Zhao, S. Qu, X. Li and Y. Li, New Developments of Ti-Based Alloys for Biomedical Applications, Materials., 2014, 7(3), p 1709–1800.10.3390/ma7031709 ↗
8. P.K. Singh, S. Kumar, P.K. Jain and U.S. Dixit, Effect of Build Orientation on Metallurgical and Mechanical Properties of Additively Manufactured Ti-6Al-4V Alloy, J. Mater. Eng. Perform., 2023, 2023(05), p 4.
9. M. Qi, B. Chen, C. Xia, Y. Liu, S. Liu, H. Zhong et al., Microstructure, Mechanical Properties and Biocompatibility of Novel Ti-20Zr-xMo Alloys, J. Alloys Comps., 2021, 888, p 161478.10.1016/j.jallcom.2021.161478 ↗
10. L.C. Zhang and L.Y. Chen, A Review on Biomedical Titanium Alloys: Recent Progress and Prospect, Adv. Eng. Mater., 2019, 21(4), p 1801215.10.1002/adem.201801215 ↗
11. J. Delgado, J. Ciurana and C.A. Rodríguez, Influence of Process Parameters on Part Quality and Mechanical Properties for DMLS and SLM with Iron-Based Materials, Int. J. Adv. Manufact. Technol., 2012, 60(5–8), p 601–610.10.1007/s00170-011-3643-5 ↗
12. M. Shunmugavel, A. Polishetty, M. Goldberg, R. Singh and G. Littlefair, A Comparative Study of Mechanical Properties and Machinability of Wrought and Additive Manufactured (Selective Laser Melting) Titanium Alloy–Ti-6Al-4V, Rapid Prototyp. J., 2017, 23, p 1051.10.1108/RPJ-08-2015-0105 ↗
13. B. Sivakumar, S. Kumar and T.S. Narayanan, Comparison of Fretting Corrosion Behaviour of Ti-6Al-4V Alloy and CP-Ti in Ringer’s Solution, Tribol. Mater. Surf. Interf., 2011, 5(4), p 158–164.10.1179/1751584X11Y.0000000020 ↗
14. Y. Xu, Y. Lu, J. Liang and R.D. Sisson, Microstructure and Corrosion Behaviour of Additively Manufactured Ti–6Al–4V with Various Post-Heat Treatments, Mater. Sci. Technol., 2019, 35(1), p 89–97.10.1080/02670836.2018.1542052 ↗
15. E. Alkhateeb and S. Virtanen, Influence of Surface Self-Modification in Ringer’s Solution on the Passive Behavior of Titanium, J. Biomed. Mater. Res. Part A Offic. J. Soc. Biomater. Japan. Soc. Biomater. Austral. Soc. Biomater. Korean Soc. Biomater., 2005, 75(4), p 934–940.
16. Petzow G. Metallographic Etching: Techniques for Metallography, Ceramography, Plastography: ASM International; 1999.
17. B.A. Boukamp, A Nonlinear Least Squares Fit Procedure for Analysis of Immittance Data of Electrochemical Systems, Solid State Ionics, 1986, 20(1), p 31–44.10.1016/0167-2738(86)90031-7 ↗
18. Tsoeunyane G, Mathe N, Tshabalala L, Makhatha M. Electropolishing of Additively Manufactured Ti-6Al-4V Surfaces in Nontoxic Electrolyte Solution. Adv. Mater. Sci. Eng. 202210.1155/2022/6987353 ↗
19. J. Bisquert, G. Garcia-Belmonte, P. Bueno, E. Longo and L. Bulhoes, Impedance of Constant Phase Element (CPE)-Blocked Diffusion in Film Electrodes, J. Electroanal. Chem., 1998, 452(2), p 229–234.10.1016/S0022-0728(98)00115-6 ↗
20. M. Simonelli, Y.Y. Tse and C. Tuck, The Formation of α+ β Microstructure in as-Fabricated Selective Laser Melting of Ti–6Al–4V, J. Mater. Res., 2014, 29(17), p 2028–2035.10.1557/jmr.2014.166 ↗
21. T. Vilaro, C. Colin and J.-D. Bartout, As-Fabricated and Heat-Treated Microstructures of the Ti-6Al-4V Alloy Processed by Selective Laser Melting, Metall. Mater. Trans. A, 2011, 42(10), p 3190–3199.10.1007/s11661-011-0731-y ↗
22. Astm G. Standard practice for calculation of corrosion rates and related information from electrochemical measurements. G102-89. 2004.
23. Roach M, Williamson R, Pegues J, Shamsaei N. A Comparison of Stress Corrosion Cracking Susceptibility in Additively Manufactured Ti-6Al-4V for Biomedical Applications. Structural Integrity of Additive Manufactured Parts: ASTM International; 2020.10.1520/STP162020180124 ↗
24. A.H. Ettefagh, C. Zeng, S. Guo and J. Raush, Corrosion Behavior of Additively Manufactured Ti-6Al-4V Parts and the Effect of Post Annealing, Addit. Manuf., 2019, 28, p 252–258.
25. J. Fojt, M. Fousova, E. Jablonska, L. Joska, V. Hybasek, E. Pruchova et al., Corrosion Behaviour and Cell Interaction of Ti-6Al-4V Alloy Prepared by Two Techniques of 3D Printing, Mater. Sci. Eng. C, 2018, 93, p 911–920.10.1016/j.msec.2018.08.066 ↗
26. F.E.-T. Heakal and K.A. Awad, Electrochemical Corrosion and Passivation Behavior of Titanium and its Ti-6Al-4V Alloy in Low and Highly Concentrated HBr Solutions, Int. J. Electrochem. Sci., 2011, 6, p 6483–6502.10.1016/S1452-3981(23)19695-7 ↗
27. A. Shukla, R. Balasubramaniam and S. Bhargava, Properties of Passive Film Formed on CP Titanium, Ti–6Al–4V and Ti–134 Al–29Nb Alloys in Simulated Human Body Conditions, Intermetallics., 2005, 13(6), p 631–637.10.1016/j.intermet.2004.10.001 ↗
28. G. Zhang and Y. Cheng, Micro-Electrochemical Characterization and Mott-Schottky Analysis of Corrosion of Welded X70 Pipeline Steel in carbonate/Bicarbonate Solution, Electrochim. Acta, 2009, 55(1), p 316–324.10.1016/j.electacta.2009.09.001 ↗
29. Y. Zhang, J. Li, S. Che and Y. Tian, Electrochemical Polishing of Additively Manufactured Ti–6Al–4V Alloy, Met. Mater. Int., 2020, 26(6), p 783–792.10.1007/s12540-019-00556-0 ↗
30. Simonelli M. Microstructure Evolution and Mechanical Properties of Selective Laser Melted Ti-6Al-4V: Loughborough University UK; 2014.10.4028/www.scientific.net/KEM.627.125 ↗
31. S. Ren, Y. Chen, T. Liu and X. Qu, Effect of Build Orientation on Mechanical Properties and Microstructure of Ti-6Al-4V Manufactured by Selective Laser Melting, Metall. Mater. Trans. A, 2019, 50(9), p 4388–4409.10.1007/s11661-019-05322-w ↗
32. J. He, D. Li, W. Jiang, L. Ke, G. Qin, Y. Ye et al., The Martensitic Transformation and Mechanical Properties of Ti6Al4V Prepared Via Selective Laser Melting, Materials., 2019, 12(2), p 321.10.3390/ma12020321 ↗