The Influence of Corrosion and Cross-Section Diameter on the Mechanical Properties of B500c Steel
Source abstract
Abstract
Corrosion is a negative contributor on the structural integrity of concrete structures and leads to degradation of the mechanical properties of steel rebar. Exposure to chloride, seawater, salt and saltwater and deicing chemical environments influences the concrete-steel bond and weakens it. A considerable strength factor of the two-phase steel B500c (martensitic, ferritic-perlitic) is considered to be the outer martensitic cortex thickness, which varies according to the area of the rebar cross section. In order to evaluate the influence of corrosion and the size of the area on the mechanical properties of B500c steel, an experimental investigation was conducted on B500c ribbed steel rebar of 8, 12, 16, and 18 mm diameter, and which were artificially corroded for 10, 20, 30, 45, 60, 90, and 120 days. The laboratory tests suggest that corrosion duration and rebar cross-sectional area size had a significant impact on the strength and ductility degradation of the specimens. The tensile mechanical properties before and after corrosion indicated progressive variation and drastic drop in their values. The extended salt spray exposure enhanced the damage and created pits and notches, resulting in stress concentration points and progressive reduction of ductility and available energy. Anti-seismic design and codes that ignore the influence of the size of the cross-section area and the level of corrosion and mechanical behavior of reinforcing steel could lead to unpredictable performance during severe ground motion.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Infrastructure Maintenance and Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. J.P. Broomfield (1997) Corrosion of Steel in Concrete. E & FN Spon., London, pp 2210.4324/9780203414606 ↗
2. V.G. Papadakis, Supplementary Cementing Materials in Concrete—Activity, Durability and Planning. Danish Technological Institute Concrete Center, January 1999
3. R. Capozucca (1995) Damage to reinforcement concrete due to reinforcement corrosion, Constr Build Mater., 9(5), p 295–303.10.1016/0950-0618(95)00033-C ↗
4. MG. Alvarez, JR. Galvele (1984) The mechanisms of pitting of high purity iron in Nacl solutions. Corrosion Science, 24, p 27–48.10.1016/0010-938X(84)90133-1 ↗
5. Glass GK, Buenfeld NR. (2000) Chloride-induced corrosion of steel in concrete. Prog Struct Eng Material 2(4):448–45810.1002/pse.54 ↗
6. C. Fang, K. Lundgren, L. Chen, and C. Zhu. Corrosion Influence on Bond in Reinforced Concrete, Cement Concrete Res, 2004, 34(11),p 2159–216710.1016/j.cemconres.2004.04.006 ↗
7. A. Ouglova, Y. Berthaud, M. François, F. Foct (2006) Mechanical properties of an iron oxide formed by corrosion in reinforced concrete structures. Corrosion Science 48(12):3988–400010.1016/j.corsci.2006.03.007 ↗
8. J.P. Broomfield, Corrosion of Steel in Concrete: Understanding, Investigation and Repair, St. Edmundsbury Press Limited, Bury St. Edmunds, Suffolk, Great Britain, 1997.10.4324/9780203414606 ↗
9. A.A. Almusallam, A.S. Al-Gahtani, A.R. Aziz, and Rasheeduzzafar, Effect of Reinforcement Corrosion on Bond Strength, J. Constr. Build. Mater., 1996, 10(2), p 123–12910.1016/0950-0618(95)00077-1 ↗
10. A.A. Almusallam, A.S. Al-Gahtani, A.R. Aziz, F.H. Dakhil, and Rasheeduzzafar, Effects of Reinforcement Corrosion on Flexural Behavior of Concrete Slabs, J. Mater. Civil Eng., 8(3), p 123–12710.1061/(ASCE)0899-1561(1996)8:3(123) ↗
11. C.A. Apostolopoulos, M.P. Papadopoulos, Sp. G. Pantelakis (2006) Tensile behaviour of corroded reinforcing steel bars BSt500 s . Journal Construction and Building Materials 20:782–9.10.1016/j.conbuildmat.2005.01.065 ↗
12. C. Apostolopoulos, D. Michalopoulos (2007) Impact of corrosion on mass loss, fatigue and hardness of BSt500 s steel. Journal of Materials Engineering and Performance 16(1):63–67.10.1007/s11665-006-9009-8 ↗
13. Ch. Alk. Apostolopoulos, D. Michalopoulos (2006) The Effect of Corrosion on the mass loss and low cycle fatigue of reinforcing steel. JMEP 15(6):742–749.10.1361/105994906X150867 ↗
14. C. Apostolopoulos, Mechanical Behavior of Corroded Reinforcing Steel Bars S500 s tempcore under Low Cycle Fatigue, Construction and Building Materials, 2007 (21), p 1447–1456.10.1016/j.conbuildmat.2006.07.008 ↗
15. C.A. Apostolopoulos, M.P. Papadopoulos (2007) Tensile and low cycle fatigue behavior of corroded reinforcing steel bars S400, Journal Construction Building Materials 21:855–86410.1016/j.conbuildmat.2005.12.012 ↗
16. M.G. Fontana (1987) Corr.Eng.3rd ed. McGraw-Hill, New York
17. Hellenic Regulation for the Technology of Steel in Reinforced Concrete, No Δ14/36010-29.2/24.3.2000 (Government Gazette Issue), 381B (in Greek)
18. EAK 2000, Ministry of Environment Planing and Public Works, Greek Earthquake Resistant Design Code. Athens, 2000 (in Greek)
19. FEMA-310, 1998, Handbook for the Seismic Evaluation of Buildings: A Prestandard, prepared by the American Society of Civil Engineers for the Federal Emergency Management Agency, Washington, DC
20. Steel for Reinforcement of Concrete—Weldable Ribbed Reinforcing Steel B500—Technical Delivery Condition for Bars, Coils and Welded Fabric prEN 100080/95
21. M. Papadopoulos, C. Apostolopoulos, N. Alexopoulos, and S. Pantelakis, Effect of Salt Spray Corrosion Exposure on the Mechanical Performance of Different Technical Class Reinforcing Steel Bars, Mater. Des., 2007, 28(8), p 2318–232810.1016/j.matdes.2006.07.017 ↗
22. ELOT 1421, Hellenic Standard Steel for the Reinforcing of Concrete—Weldable Reinforcing Steel—Part 1, 2, 3: Technical class B500c, Athens, 2004