journal article·2022-01

Three-Dimensional Printing of Innovative Intramedullary Pin Profiles with Direct Metal Laser Sintering

Rupinder Singh, Jashanpreet Singh Sidhu, Rishab, B. S. Pabla, Ashwani Kumar

Publisher page

Abstract

In the past one decade, use of intramedullary (IM) pins (Steinmann pins or end-threaded pins) as implants for the repair of long bone fractures in canine has been widely reported. One of the major limitations of these pins is implant dislodgement and proximal migration mainly due to less retention rate in the proximal end. Some studies have reported the fabrication of IM pins for canine by conventional machining methods, but hitherto little has been reported on the innovative profiles of IM pins for canine prepared by direct metal laser sintering (DMLS) of 17-4 precipitation-hardening (PH) stainless steel (SS). This paper reports the fabrication and process parametric optimization for innovative IM pin profiles on 17-4PH SS with DMLS. The selected output parameters are surface hardness (HV), surface roughness (Ra), and dimensional error (∆d). The results of the study suggest that laser power 100 W, scan speed 1200 mm/s, and layer thickness-0.04-mm are the best settings of DMLS from a multi-factor optimization viewpoint. The results have been supported with scanning electron microscopy-based photo-micrographs, 3D rendered images, porosity (%), and grain size number.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Additive Manufacturing and 3D Printing Technologies · Anatomy and Medical Technology · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Standard, A.S.T.M., 2012. F2792-12a" Terminology for Additive Manufacturing Technologies". ASTM International. West Conshohocken https://doi.org/10.1520/F2792-12A.10.1520/F2792-12A ↗
2. J.P. Kruth, M.C. Leu and T. Nakagawa, Progress in Additive Manufacturing and Rapid Prototyping, CIRP Ann., 1998, 47(2), p 525–540.10.1016/S0007-8506(07)63240-5 ↗
3. D.T. Pham and S.S. Dimov, Rapid Prototyping and Rapid Tooling—The Key Enablers for Rapid Manufacturing, Proc. Inst. Mech. Eng. C J. Mech. Eng. Sci., 2003, 217(1), p 1–23.10.1243/095440603762554569 ↗
4. I. Campbell, O. Diegel, J. Kowen and T. Wohlers, Wohlers Report 2018: 3D Printing and Additive Manufacturing State of the Industry: Annual Worldwide Progress Report, Wohlers Associates, New York, 2018.
5. L. Kumar, Q. Tanveer, V. Kumar, M. Javaid and A. Haleem, Developing Low-Cost 3 D Printer, Int. J. Appl. Sci. Eng. Res., 2016, 5(6), p 433–447.
6. S. Peel, D. Eggbeer, H. Burton, H. Hanson and P.L. Evans, Additively Manufactured Versus Conventionally Pressed Cranioplasty Implants: An Accuracy Comparison, Proc. Inst. Mech. Eng. [H], 2018, 232(9), p 949–961.10.1177/0954411918794718 ↗
7. R. Bibb, D. Eggbeer, P. Evans, A. Bocca and A. Sugar, Rapid Manufacture of Custom-Fitting Surgical Guides, Rapid Prototyp. J., 2009, 15, p 346–354.10.1108/13552540910993879 ↗
8. A.J. Festas, A. Ramos and J.P. Davim, Medical Devices Biomaterials–A Review, Proc. Inst. Mech. Eng. Part L J. Mater. Des. Appl., 2020, 234(1), p 218–228.
9. D.F. Williams, Biofunctionality and biocompatibility. Materials Science and Technology, 200610.1002/9783527603978.mst0160 ↗
10. M. Saini, Y. Singh, P. Arora, V. Arora and K. Jain, Implant Biomaterials: A Comprehensive Review, World J. Clin. Cases, 2015, 3(1), p 52–57. https://doi.org/10.12998/wjcc.v3.i1.5210.12998/wjcc.v3.i1.52 ↗
11. S. Hosseini, S. Mirdamadi and A. Nemati, Porous Ti6Al4V Scaffolds for Dental Implants: Microstructure, Mechanical, and Corrosion Behavior, Proc. Inst. Mech. Eng. Part L J. Mater. Des. Appl., 2016, 230(5), p 927–933.
12. D.H. Kohn, P. Ducheyne, Materials for Bone and Joint Replacement. Materials Science and Technology, 200610.1002/9783527603978.mst0161 ↗
13. R.N. Brown, B.E. Sexton, T.M.G. Chu, T.R. Katona, K.T. Stewart, H.M. Kyung and S.S.Y. Liu, Comparison of Stainless Steel and Titanium Alloy Orthodontic Mini Screw Implants: A Mechanical and Histologic Analysis, Am. J. Orthod. Dentofac. Orthop., 2014, 145(4), p 496–504.10.1016/j.ajodo.2013.12.022 ↗
14. I. Mutlu and E. Oktay, Biocompatibility of 17–4 PH Stainless Steel Foam for Implant Applications, Bio-Med. Mater. Eng., 2011, 21(4), p 223–233.10.3233/BME-2011-0671 ↗
15. L.E.E. Jae-Ho, J.A.N.G. Jeong-Hwan, J.O.O. Byeong-Don, Y.I.M. Hong-Sup and M.O.O.N. Young-Hoon, Application of Direct Laser Metal Tooling for AISI H13 Tool Steel, Trans. Nonferrous Met. Soc. China, 2009, 19, p s284–s287.10.1016/S1003-6326(10)60286-5 ↗
16. T. Duda and L.V. Raghavan, 3D Metal Printing Technology, IFAC-PapersOnLine, 2016, 49(29), p 103–110.10.1016/j.ifacol.2016.11.111 ↗
17. T. Altan, B. Lilly and Y.C. Yen, Manufacturing of Dies and Molds, CIRP Ann., 2001, 50(2), p 404–422.10.1016/S0007-8506(07)62988-6 ↗
18. M. Krishnan, E. Atzeni, R. Canali, F. Calignano, D. Manfredi, E.P. Ambrosio and L. Iuliano, On the Effect of Process Parameters on Properties of AlSi10Mg Parts Produced by DMLS, Rapid Prototyp. J., 2014, 20, p 449–458.10.1108/RPJ-03-2013-0028 ↗
19. J. Delgado, J. Ciurana and C.A. Rodriguez, Influence of Process Parameters on Part Quality and Mechanical Properties for DMLS and SLM with Iron-Based Materials, Int. J. Adv. Manuf. Technol., 2012, 60(5–8), p 601–610.10.1007/s00170-011-3643-5 ↗
20. R.D.N. Libardoni, G.M.C. Serafini, C.D. Oliveira, P.I. Schimites, R.O. Chaves, J.P.S. Feranti, C.A.S. Costa, A.S.D. Amaral, A.G. Raiser and A.V. Soares, Appendicular Fractures of Traumatic Etiology in Dogs: 955 Cases (2004–2013), Ciência Rural, 2016, 46(3), p 542–546.10.1590/0103-8478cr20150219 ↗
21. N. Rosa, M. Marta, M. Vaz, S.M. Tavares, R. Simoes, F.D. Magalhães and A.T. Marques, Intramedullary Nailing Biomechanics: Evolution and Challenges, Proc. Inst. Mech. Eng. [H], 2019, 233(3), p 295–308.10.1177/0954411919827044 ↗
22. P. Kumar and T.K. Gahlot, Clinical Evaluation of Intramedullary Pinning and Interlocking Nailing Technique for Stabilization of Femoral Fractures in Dogs, J. Anim. Sci. Adv., 2013, 3(6), p 310–313.10.5455/jasa.20130331052115 ↗
23. C.P. Laurent, B. Böhme, J. Verwaerde, L. Papeleux, J.P. Ponthot and M. Balligand, Effect of Orthopedic Implants on Canine Long Bone Compression Stiffness: A Combined Experimental and Computational Approach, Proc. Inst. Mech. Eng. [H], 2020, 234(3), p 255–264.10.1177/0954411919882603 ↗
24. T.D. Braden and W.O. Brinker, Radiologic and Gross Anatomic Evaluation of Bone Healing in the Dog, J. Am. Vet. Med. Assoc., 1976, 169(12), p 1318–1323.
25. M. Jagodzinski and C. Krettek, Effect of Mechanical Stability on Fracture Healing—An Update, Injury, 2007, 38(1), p S3–S10.10.1016/j.injury.2007.02.005 ↗
26. C.E. DeCamp, S.A. Johnston, L.M. Déjardin, S.L. Schaefer, The hip joint. Brinker, Piermattei, and Flo’s Handbook of Small Animal Orthopedics and Fracture Repair. 5th and. St. Louis: Elsevier, 2016, pp. 468–51710.1016/B978-1-4377-2364-9.00025-2 ↗
27. P.C. Frake, R.J. Howell and A.S. Joshi, Strength of Titanium Intramedullary Implant Versus Miniplate Fixation of Mandibular Condyle Fractures, Otolaryngol. Head Neck Surg., 2012, 147(1), p 33–39.10.1177/0194599812439391 ↗
28. A. Kaur, A. Kumar, D. Kumar, J. Mohindroo and N.S. Saini, Feasibility of C-Arm Guided Closed Intramedullary Pinning for the Stabilization of Canine Long Bone Fractures, Vet. World, 2015, 8(12), p 1410.10.14202/vetworld.2015.1410-1415 ↗
29. K. Altunatmaz, S. Ozsoy, Z. Mutlu, Y. Devecioglu and O. Guzel, Use of Intramedullary Fully Threaded Pins in the Fixation of Feline and Canine Humeral, Femoral and Tibial Fractures, Vet. Comp. Orthop. Traumatol., 2012, 25(04), p 321–325.10.3415/VCOT-11-05-0068 ↗
30. K.H. Kraus, S.M. Fox, F.S. Pike and E.C. Salzer, Small Animal Fracture Repair: A Case-Based Approach, CRC Press, London, 2016.10.1201/9781315369891 ↗