Appendix: 105-S06 Temporary Corrosion Protection and Bond of Prestressing Steel
Source abstract
Abstract
The results of laboratory and field tests to investigate the perfomance of different temporary corrosion protection methods for prestressing steel are presented. It is demonstrated that a particular emulsifiable oil product applied to the prestressing steel showed by far the best corrosion protection behavior. Using this product, a pullout test with a long embedment length was performed on a post-tensioned seven-strand tendon with a plastic duct and compared with a reference test using untreated strands. Compared with the untreated strands, a bond shear stress reduction by a factor of approximately 2.5 was observed. It is shown that, generally, this reduction does not significantly influence the load-deformation response of post-tensioned concrete members and that the emulsifiable oil does not need to be removed before grouting of the tendons.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.