Hardware-In-the-Loop Equipment for the Development of an Automatic Perturbator for Clinical Evaluation of Human Balance Control
Source abstract
Abstract
Nowadays, increasing attention is being paid to techniques aimed at assessing a subject’s ability to maintain or regain control of balance, thus reducing the risk of falls. To this end, posturographic analyses are performed in different clinical settings, both in unperturbed and perturbed conditions. This article presents a new Hardware-In-the-Loop (HIL) equipment designed for the development of an automatic perturbator for postural control analysis, capable of providing controlled mechanical stimulation by means of an impulsive force exerted on a given point of the body. The experimental equipment presented here includes the perturbator and emulates its interaction with both the subject’s body and the operator performing the test. The development of the perturbator and of the entire HIL equipment is described, including component selection, modeling of the entire system, and experimentally verified simulations used to study and define the most appropriate control laws.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Balance, Gait, and Falls Prevention · Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Turin, Italy
Department of Neuroscience, University of Torino, 10125 Turin, Italy
Department of Physical Therapy, Tel Aviv University, Tel Aviv 6997801, Israel
Funding
Politecnico di Torino (Italy)
References (46)
Show source-provided references
1. Control of grip force and vertical posture while holding an object and being perturbed10.1007/s00221-016-4717-2 ↗
2. Neural control of posture during small magnitude perturbations: Effects of aging and localized muscle fatigue10.1109/TBME.2010.2095500 ↗
3. Home-Based Risk of Falling Assessment Test Using a Closed-Loop Balance Model10.1109/TNSRE.2015.2508960 ↗
4. Light touch modulates balance recovery following perturbation: From fast response to stance restabilization10.1007/s00221-015-4214-z ↗
5. Anticipatory postural adjustments and anticipatory synergy adjustments: Preparing to a postural perturbation with predictable and unpredictable direction10.1007/s00221-016-4835-x ↗
6. Human postural control against external force perturbation applied to the high-back
7. Role of point of application of perturbation in control of vertical posture10.1007/s00221-017-5069-2 ↗
8. Postural responses to anterior and posterior perturbations applied to the upper trunk of standing human subjects10.1007/s00221-015-4442-2 ↗
9. Duncan, C.A., Ingram, T.G.J., Mansfield, A., Byrne, J.M., and McIlroy, W.E. (2016). Population Differences in Postural Response Strategy Associated with Exposure to a Novel Continuous Perturbation Stimuli: Would Dancers Have Better Balance on a Boat?. PLoS ONE, 11.10.1371/journal.pone.0165735 ↗
10. Central programming of postural movements: Adaptation to altered support-surface configurations10.1152/jn.1986.55.6.1369 ↗
11. Postural responses evoked by platform perturbations are dominated by continuous feedback10.1152/jn.00457.2006 ↗
12. Assessment of the underlying systems involved in standing balance: The additional value of electromyography in system identification and parameter estimation10.1186/s12984-017-0299-x ↗
13. The test-retest reliability of centre of pressure measures in bipedal static task conditions--a systematic review of the literature10.1016/j.gaitpost.2010.09.012 ↗
14. Measures of postural steadiness: Differences between healthy young and elderly adults10.1109/10.532130 ↗
15. Older adults utilize less efficient postural control when performing pushing task10.1016/j.jelekin.2015.09.002 ↗
16. Short-latency muscle response patterns to multi-directional, unpredictable perturbations to balance applied to the arm are context dependent10.1016/j.neuroscience.2017.03.062 ↗
17. A robotic system for delivering novel real-time, movement dependent perturbations10.1016/j.gaitpost.2017.08.038 ↗
18. Identification of the contribution of the ankle and hip joints to multi-segmental balance control10.1186/1743-0003-10-23 ↗
19. Standing balance evaluation using a triaxial accelerometer10.1016/S0966-6362(01)00199-0 ↗
20. An accelerometry-based system for the assessment of balance and postural sway10.1159/000021981 ↗
21. Trunk accelerometry as a measure of balance control during quiet standing10.1016/S0966-6362(01)00200-4 ↗
22. Test-retest reliability of trunk accelerometric gait analysis10.1016/S0966-6362(03)00069-9 ↗
23. Postural feedback responses scale with biomechanical constraints in human standing10.1007/s00221-003-1674-3 ↗
24. On the Role of Dynamic Models in Quantitative Posturography10.1109/TBME.1980.326583 ↗
25. Identifying mechanisms of stance control: A single stimulus multiple output model-fit approach10.1016/j.jneumeth.2017.12.015 ↗
26. An adaptive model of sensory integration in a dynamic environment applied to human stance control10.1007/s004220000196 ↗
27. On making robots understand safety: Embedding injury knowledge into control10.1177/0278364912462256 ↗
28. Applications of artificial intelligence in safe human-robot interactions10.1109/TSMCB.2010.2058103 ↗
29. Human-intent detection and physically interactive control of a robot without force sensors10.1109/TRO.2010.2040202 ↗
30. Muscolo, G., Marcheschi, S., Fontana, M., and Bergamasco, M. (2020). Dynamics Modeling of Human–Machine Control Interface for Underwater Teleoperation. Robotica, 1–15.10.1017/S0263574720000624 ↗
31. Effects of Impedance Reduction of a Robot for Wrist Rehabilitation on Human Motor Strategies in Healthy Subjects during Pointing Tasks10.1163/016918611X558270 ↗
32. Hand rehabilitation device actuated by a pneumatic muscle10.1007/978-3-030-00232-9_11 ↗
33. Heidingsfeld, M., Feuer, R., Karlovic, K., Maier, T., and Sawodny, O. (2014, January 5–8). A force-controlled human-assistive robot for laparoscopic surgery. Proceedings of the 2014 IEEE International Conference on Systems, Man, and Cybernetics (SMC), San Diego, CA, USA.10.1109/SMC.2014.6974460 ↗
34. The parallel approach to force/position control of robotic manipulators10.1109/70.246048 ↗
35. Impedance control for a pneumatic robot-based around pole-placement, joint space controllers10.1016/j.conengprac.2004.03.011 ↗
36. Dynamic Modeling and Interactive Performance of PARM: A Parallel Upper-Limb Rehabilitation Robot Using Impedance Control for Patients after Stroke10.1155/2018/8647591 ↗
37. Hybrid impedance control of robotic manipulators10.1109/56.20440 ↗
38. Frequency-Shaped Impedance Control for Safe Human–Robot Interaction in Reference Tracking Application10.1109/TMECH.2014.2309118 ↗
39. A high performance pneumatic force actuator system: Part II—nonlinear controller design
40. Tracking control of non-linear systems using sliding surfaces, with application to robot manipulators10.1080/00207178308933088 ↗
41. Pressure estimation-based robust force control of pneumatic actuators10.1080/14399776.2013.10781067 ↗
42. Pneumo-tronic Perturbator for the Study of Human Postural Responses10.1007/978-3-030-19648-6_43 ↗
43. Development of an automatic perturbator for dynamic posturographic analysis
44. Stiffness control of balance in quiet standing10.1152/jn.1998.80.3.1211 ↗
45. Fast online corrections of tripping responses10.1007/s00221-014-4038-2 ↗
46. Linearity and repeatability of postural responses in relation to peak force and impulse of manually delivered perturbations: A preliminary study10.1007/s00421-020-04364-y ↗