Effects of Temperature Variations during Sintering of Metal Ceramic Tooth Prostheses Investigated Non-Destructively with Optical Coherence Tomography
Source abstract
Abstract
Calibration loss of ovens used in sintering metal ceramic prostheses leads to stress and cracks in the material of the prostheses fabricated, and ultimately to failure of the dental treatment. Periodic calibration may not be sufficient to prevent such consequences. Evaluation methods based on firing supplemental control samples are subjective, time-consuming, and rely entirely on the technician’s skills. The aim of this study was to propose an alternative procedure for such evaluations. Fifty prostheses were sintered in a ceramic oven at a temperature lower, equal to or larger than the temperature prescribed by the manufacturer. A non-destructive imaging method, swept source (SS) optical coherence tomography (OCT) was used to evaluate comparatively the internal structure of prostheses so fabricated. A quantitative assessment procedure is proposed, based on en-face OCT images acquired at similar depths inside the samples. Differences in granulation and reflectivity depending on the oven temperature are used to establish rules-of-thumb on judging the correct calibration of the oven. OCT evaluations made on a regular basis allow an easy and objective monitoring of correct settings in the sintering process. This method can serve rapid identification of the need to recalibrate the oven and avoid producing prostheses with defects.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Optical Coherence Tomography Applications · Photoacoustic and Ultrasonic Imaging · Endodontics and Root Canal Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Dental Medicine, Victor Babes University of Medicine and Pharmacy of Timisoara, 2A Eftimie Murgu Place, Timisoara 300070, Romania
Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury CT2 7NH, UK
3OM Optomechatronics Group, Faculty of Engineering, Aurel Vlaicu University of Arad, 77 Revolutiei Ave., Arad 310130, Romania
Doctoral School, Polytechnic University of Timisoara, 1 Mihai Viteazu Ave., Timisoara 300222, Romania
References (38)
Show source-provided references
1. A review of all ceramic restorations10.14219/jada.archive.1997.0193 ↗
2. Mechanical properties of commercial high strength ceramic core materials10.1016/S0109-5641(03)00093-9 ↗
3. Indentation fracture toughness and dynamic elastic moduli for commercial feldspathic dental porcelain materials10.1016/S0109-5641(03)00092-7 ↗
4. Ceramics for dental restorations—An Introduction
5. Shear Bond Strength Tests of Zirconia Veneering Ceramics after Chipping Repair10.1080/01694243.2015.1117304 ↗
6. Porcelain and Pressing Furnaces. Inside Dental Technology
7. (2017, March 23). VITA. Available online: http://vitanorthamerica.com/products/equipment/vacumat-6000-m/.
8. Temperature variation in metal ceramic technology analyzed using time domain optical coherence tomography10.1117/12.2045848 ↗
9. Optical coherence tomography10.1126/science.1957169 ↗
10. Drexler, W., and Fujimoto, J.G. (2008). Optical Coherence Tomography, Springer.10.1007/978-3-540-77550-8 ↗
11. Optical coherence tomography10.1111/j.1365-2818.2012.03619.x ↗
12. Wijesinghe, R.E., Cho, N.H., Park, K., Jeon, M., and Kim, J. (2016). Bio-Photonic detection and quantitative evaluation method for the progression of dental caries using optical frequency-domain imaging method. Sensors, 16.10.3390/s16122076 ↗
13. High-speed optical coherence tomography: Basics and applications10.1364/AO.49.000D30 ↗
14. Optical coherence tomography today: Speed, contrast and multimodality10.1117/1.JBO.19.7.071412 ↗
15. Master–slave interferometry for parallel spectral domain interferometry sensing and versatile 3D optical coherence tomography10.1364/OE.21.019324 ↗
16. Three-dimensional imaging of normal skin and nonmelanoma skin cancer with cellular resolution using Gabor domain optical coherence microscopy10.1117/1.JBO.17.12.126006 ↗
17. Dental OCT10.1364/OE.3.000230 ↗
18. Quality assessment of dental treatments using en-face optical coherence tomography10.1117/1.2992593 ↗
19. Effects of structural orientation of enamel and dentine on light attenuation and local refractive index: An optical coherence tomography study10.1016/j.jdent.2012.01.017 ↗
20. Diagnosis of vertical root fractures with optical coherence tomography10.1016/j.joen.2008.03.013 ↗
21. Optical endomicroscopy and the road to real-time, in vivo pathology: Present and future10.1186/1746-1596-7-98 ↗
22. Polarization sensitive optical coherence tomography for technical materials investigation10.1016/j.sna.2007.04.016 ↗
23. Optical coherence tomography for quality assessment of embedded microchannels in alumina ceramic10.1364/OE.20.004603 ↗
24. Surface imaging of metallic material fractures using optical coherence tomography10.1364/AO.53.005912 ↗
25. In Vivo OCT imaging of hard and soft tissue of the oral cavity10.1364/OE.3.000239 ↗
26. Estimation of lesion progress in artificial root caries by swept source optical coherence tomography in comparison to transverse microradiography10.1117/1.3600448 ↗
27. Schneider, H., Park, K.-J., Häfer, M., Rüger, C., Schmalz, G., Krause, F., Schmidt, J., Ziebolz, D., and Haak, R. (2017). Dental applications of optical coherence tomography (OCT) in cariology. Appl. Sci., 7.10.3390/app7050472 ↗
28. Assessing near infrared optical properties of ceramic orthodontic brackets using cross-polarization optical coherence tomography10.1002/jbm.b.33029 ↗
29. Assessment of curing behavior of light-activated dental composites using intensity correlation based multiple reference optical coherence tomography10.1002/lsm.22447 ↗
30. Imaging artificial caries under composite sealants and restorations10.1117/1.1805562 ↗
31. Handheld scanning probes for optical coherence tomography
32. Non-destructive evaluation of an internal adaptation of resin composite restoration with swept-source optical coherence tomography and micro-CT10.1016/j.dental.2015.10.009 ↗
33. Optical Coherence Tomography for Non-Invasive ex vivo Investigations in Dental Medicine—A Joint Group Experience (Review)
34. (2017, April 26). DeguDent. Available online: http://www.salloumtrade.com/categories.php?act=show&id=62.
35. Optimization of galvanometer scanning for Optical Coherence Tomography10.1364/AO.54.005495 ↗
36. Depth enhancement in spectral domain optical coherence tomography using bidirectional imaging modality with a single spectrometer10.1117/1.JBO.21.7.076005 ↗
37. Theory of the dependence of densification on grain growth during intermediate stage sintering10.1111/j.1151-2916.1975.tb11437.x ↗
38. Perko, S. (2012). Dental Ceramics. [Ph.D. Thesis, Jozef Stefan International Postgraduate School].