Electric field measurements in preclinical MRI at 11.7 T and 7 T for experimental SAR comparison
Source abstract
Abstract
The aim of the current study is to demonstrate the feasibility of radiofrequency (RF) pulses generated via an optimal control (OC) algorithm to perform magnetic resonance elastography (MRE) and quantify the mechanical properties of materials with very short transverse relaxation times (T2 < 5 ms) for the first time. OC theory applied to MRE provides RF pulses that bring isochromats from the equilibrium state to a fixed target state, which corresponds to the phase pattern of a conventional MRE acquisition. Such RF pulses applied with a constant gradient allow to simultaneously perform slice selection and motion encoding in the slice direction. Unlike conventional MRE, no additional motion‐encoding gradients (MEGs) are needed, enabling shorter echo times. OC pulses were implemented both in turbo spin echo (OC rapid acquisition with refocused echoes [RARE]) and ultrashort echo time (OC UTE) sequences to compare their motion‐encoding efficiency with the conventional MEG encoding (classical MEG MRE). MRE experiments were carried out on agar phantoms with very short T2 values and on an ex vivo bovine tendon. Magnitude images, wave field images, phase‐to‐noise ratio (PNR), and shear storage modulus maps were compared between OC RARE, OC UTE, and classical MEG MRE in samples with different T2 values. Shear storage modulus values of the agar phantoms were in agreement with values found in the literature, and that of the bovine tendon was corroborated with rheometry measurements. Only the OC sequences could encode motion in very short T2 samples, and only OC UTE sequences yielded magnitude images enabling proper visualization of short T2 samples and tissues. The OC UTE sequence produced the best PNRs, demonstrating its ability to perform anatomical and mechanical characterization. Its success warrants in vivo confirmation in further studies.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced MRI Techniques and Applications · Ultrasound and Hyperthermia Applications · Atomic and Subatomic Physics Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. MRI safety and devices: An update and expert consensus10.1002/jmri.26909 ↗
2. Risks related to static magnetic fields10.1016/j.ejmp.2016.07.272 ↗
3. Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?
4. A quick guide to safety and compatibility of passive implants and devices in an MR environment10.4102/sajr.v8i2.126 ↗
5. Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil10.1002/mrm.1091 ↗
6. Hazardous situation in the MR bore: induction in ECG leads causes fire10.1007/s00330-003-1841-8 ↗
7. Complexity of MRI induced heating on metallic leads: Experimental measurements of 374 configurations10.1186/1475-925X-7-11 ↗
8. RF power design optimization in MRI system10.1016/j.mrl.2021.100006 ↗
9. Armenean C, Perrin E, Armenean M, Beuf O, Pilleul F, Saint-Jalmes H. RF induced temperature elevation near metallic wires in clinical magnetic resonance imaging. In: Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2003. Vol 1. ; 2003:501-504 Vol.1. doi:10.1109/IEMBS.2003.1279745.10.1109/IEMBS.2003.1279745 ↗
10. MR heating tests of MR critical implants10.1002/jmri.21020 ↗
11. Advances in MRI around metal: MRI Around Metal10.1002/jmri.25708 ↗
12. The dielectric properties of biological tissues: I. Literature survey10.1088/0031-9155/41/11/001 ↗
13. Pros and cons of ultra-high-field MRI/MRS for human application10.1016/j.pnmrs.2018.06.001 ↗
14. Key clinical benefits of neuroimaging at 7 T10.1016/j.neuroimage.2016.11.031 ↗
15. High-field FMRI for human applications: an overview of spatial resolution and signal specificity10.2174/1874440001105010074 ↗
16. Ultra-High-Field Magnetic Resonance Spectroscopy in Psychiatry10.3389/fpsyt.2017.00123 ↗
17. Signal-to-noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arrays10.1002/mrm.25677 ↗
18. IEC. Particular Requirements for the Basic Safety and Essential Performance of Magnetic Resonance Equipment for Medical Diagnosis. https://webstore.iec.ch/preview/info_iec60601-2-33%7Bed3.1%7Db.pdf.
19. A prototype RF dosimeter for independent measurement of the average specific absorption rate (SAR) during MRI10.1002/jmri.21141 ↗
20. Analytical analysis of the Pennes bioheat transfer equation with sinusoidal heat flux condition on skin surface10.1016/j.medengphy.2006.10.008 ↗
21. Experimental and numerical assessment of MRI-induced temperature change and SAR distributions in phantoms and in vivo: Temperature and SAR Distributions in MRI10.1002/mrm.22174 ↗
22. An anatomically realistic temperature phantom for radiofrequency heating measurements: Realistic Temperature Phantom for Radiofrequency Heating Measurements10.1002/mrm.25123 ↗
23. Sensitivity and Power Deposition in a High-Field Imaging Experiment10.1002/1522-2586(200007)12:1<46::AID-JMRI6>3.0.CO;2-D ↗
24. Fiedler · SAR Simulations & Safety. Neuroimage. · 2018 · 168 · 33
25. Electro-optic probe for real-time assessments of RF electric field produced in an MRI scanner: Feasibility tests at 3 and 4.7 T10.1002/nbm.3849 ↗
26. Common modes and cable traps" in
27. Parallel transmission for ultrahigh-field imaging: Parallel Transmission for Ultrahigh-Field Imaging10.1002/nbm.3313 ↗
28. Magnetic-Resonance-Based Electrical Properties Tomography: a review
29. Determination of Electric Conductivity and Local SAR Via B1 Mapping10.1109/TMI.2009.2015757 ↗
30. J.A. Martinez A. Arduino O. Bottauscio L. Zilberti Evaluation and Correction of B1+-Based Brain Subject-Specific SAR Maps Using Electrical Properties Tomography IEEE J Electromagn RF Microw Med Biol. Published online 2023 1–8 10.1109/JERM.2023.3236153.10.1109/JERM.2023.3236153 ↗
31. Proton Resonance Frequency Shift Thermometry: A Review of Modern Clinical Practices10.1002/jmri.27446 ↗
32. Evaluation of MR thermometry with proton resonance frequency method at 7T10.21037/qims.2017.03.05 ↗
33. From Complex B1 Mapping to Local SAR Estimation for Human Brain MR Imaging Using Multi-Channel Transceiver Coil at 7T10.1109/TMI.2013.2251653 ↗
34. Synthesized tissue-equivalent dielectric phantoms using salt and polyvinylpyrrolidone solutions: Synthesized Tissue-Equivalent Dielectric Properties Using a Water-Soluble Polymer10.1002/mrm.27005 ↗
35. Rheology and heat transport properties of a hydroxyethyl cellulose-based MRI tissue phantom10.1088/2057-1976/aa7a41 ↗
36. Electric field measurements and computational modeling at ultrahigh-field MRI10.1016/j.mri.2007.01.115 ↗
37. Spatial distribution of RF-induced E-fields and implant heating in MRI10.1002/mrm.21475 ↗
38. Loader B, Gregory A, Bownds D, Seifert F. Evaluation of an optical electric field sensor for measurement of specific absorption rate (SAR) during magnetic resonance imaging. In: 2012 International Symposium on Electromagnetic Compatibility (EMC EUROPE). ; 2012:1-4. doi:10.1109/EMCEurope.2012.6396819.10.1109/EMCEurope.2012.6396819 ↗
39. Measurement and evaluation of specific absorption rate and temperature elevation caused by an artificial hip joint during MRI scanning10.1038/s41598-020-80828-7 ↗
40. Temperature and SAR measurement errors in the evaluation of metallic linear structures heating during MRI using fluoroptic® probes10.1088/0031-9155/52/6/006 ↗
41. Estimation of convection heat transfer coefficient and surface emissivity of a nonreacting specimen in cone calorimeter using RPSO method10.1007/s12206-013-0402-6 ↗
42. Seo JH, Ryu Y, Chung JY. Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging. Sensors. 2022;22(11):4274. doi:10.3390/s22114274.10.3390/s22114274 ↗
43. MRI in Rodent Models of Brain Disorders10.1007/s13311-010-0002-4 ↗
44. Direct control of the temperature rise in parallel transmission by means of temperature virtual observation points: Simulations at 10.5 tesla: Control of Temperature Rise in Parallel Transmission10.1002/mrm.25637 ↗