Development and implementation of a tomographic system for the quantitative reconstruction of magnetic microparticles based on AC biosusceptometry sensors
Source abstract
Abstract
Micro and nanostructured magnetic materials (MNMMs) are materials with great potential for several biomedical applications, due to their magnetic properties and small size. However, for better targeting process efficiency, techniques capable of detecting, locating and imaging MNMMs within the organism are necessary. Currently there are some techniques available, but with some disadvantages such as high cost, lack of portability, and restrictions for animal experimentation. Thus, Alternating Current Biosusceptometry (ACB) is an alternative biomagnetic technique capable of detecting and performing quantitative imaging of MNMMs in vitro, ex vivo, in vivo, and in real-time. So far, the ACB results presented were restricted to quantitative planar images. To generate quantitative tomographic images using the ACB, we propose an octagonal array of pick-up and excitation coils arranged in an octagonal geometry, enabling acquisition in different projections. This configuration formed by multiple pick-up and excitation coils allowed us to test different methods and setups of coils activation. These different methods and setups enabled a deeper analysis of the ACB inverse problem stability and details. The results showed that the addition of pick-up coils resulted in a better reconstruction due to the amount of information added to the problem. Here we show for the first time the ACB quantitative tomographic reconstruction of magnetic materials distribution.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Geomagnetism and Paleomagnetism Studies · Electrical and Bioimpedance Tomography
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Magnetic micro-and nano-particle-based targeting for drug and gene delivery
2. Advances in stem cell research and therapeutic development10.1038/s41556-019-0344-z ↗
3. Magnetic Nanoparticles: Current Advances in Nanomedicine, Drug Delivery and MRI10.3390/chemistry4030063 ↗
4. Magnetic nanoparticles: From synthesis to theranostic applications10.1021/acsanm.1c00852 ↗
5. Targeted and controlled drug delivery to a rat model of heart failure through a magnetic nanocomposite10.1007/s10439-019-02394-y ↗
6. Contrast agents as a biological marker in magnetic resonance imaging of the liver: conventional and new approaches10.1007/s00261-011-9734-9 ↗
7. Advanced Magnetic Resonance Imaging (MRI) Techniques: Technical Principles and Applications in Nanomedicine10.3390/cancers14071626 ↗
8. Structure–relaxivity relationships of magnetic nanoparticles for magnetic resonance imaging10.1002/adma.201804567 ↗
9. Biology. Three-dimensional real-time in vivo magnetic particle imaging10.1088/0031-9155/54/5/L01 ↗
10. Biology. Development of a magnetic nanoparticle susceptibility magnitude imaging array10.1088/0031-9155/59/4/1047 ↗
11. Adaptive control of excitation coil arrays for targeted magnetic nanoparticle reconstruction using magnetorelaxometry10.1109/TMAG.2012.2201706 ↗
12. Advancements in magnetic nanoparticle reconstruction using sequential activation of excitation coil arrays using magnetorelaxometry10.1109/TMAG.2011.2173317 ↗
13. Magnetic resonance imaging: Review of imaging techniques and overview of liver imaging10.4329/wjr.v2.i8.309 ↗
14. Prospero, A.G.; Buranello, L.P.; Fernandes, C.A.; Dos Santos, L.D.; Soares, G.; C Rossini, B.; Zufelato, N.; Bakuzis, A.F.; de Mattos Fontes, M.R.; de Arruda Miranda, J.R.J.N. Corona protein impacts on alternating current biosusceptometry signal and circulation times of differently coated MnFe2O4 nanoparticles. Nanomedicine 2021, 16, 2189-2206.10.2217/nnm-2021-0195 ↗
15. AC biosusceptometry and magnetic nanoparticles to assess doxorubicin-induced kidney injury in rats10.2217/nnm-2019-0300 ↗
16. Biology. Magnetic images of the disintegration process of tablets in the human stomach by ac biosusceptometry10.1088/0031-9155/50/23/007 ↗
17. Multichannel AC Biosusceptometry system to map biodistribution and assess the pharmacokinetic profile of magnetic nanoparticles by imaging10.1109/TNB.2019.2912073 ↗
18. 2D Quantitative Imaging of Magnetic Nanoparticles by an AC Biosusceptometry Based Scanning Approach and Inverse Problem10.3390/s21217063 ↗
19. Soares, G., Pinto, L., Liebl, M., Biasotti, G., Prospero, A., Stoppa, E., Bakuzis, A., Baffa, O., Wiekhorst, F., Miranda, J.R.A. Quantitative imaging of magnetic nanoparticles in an unshielded environment using a large AC susceptibility array. 2022, 16(1), 25.10.1186/s13036-022-00305-9 ↗
20. Plane-wise sensitivity based inhomogeneous excitation fields for magnetorelaxometry imaging of magnetic nanoparticles10.1016/j.jmmm.2014.09.007 ↗
21. Evaluating selection criteria for optimized excitation coils in magnetorelaxometry imaging10.1088/1361-6560/ac36e8 ↗
22. Quantitative imaging of magnetic nanoparticles by magnetorelaxometry with multiple excitation coils10.1088/0031-9155/59/21/6607 ↗
23. Compact expressions for the Biot-Savart fields of a filamentary segment10.1063/1.1507589 ↗
24. Vision. Optimizing excitation coil currents for advanced magnetorelaxometry imaging10.1007/s10851-019-00934-8 ↗
25. Quantitative 2D magnetorelaxometry imaging of magnetic nanoparticles using optically pumped magnetometers10.3390/s20030753 ↗
26. Uncertainty of reconstructions of spatially distributed magnetic nanoparticles under realistic noise conditions10.1063/1.4863801 ↗
27. A guide to appropriate use of correlation coefficient in medical research
28. Computing. Analysis and development of AC biosusceptometer for orocaecal transit time measurements10.1007/BF02510514 ↗
29. Employment of a noninvasive magnetic method for evaluation of gastrointestinal transit in rats10.1186/1754-1611-6-6 ↗
30. Quantitative model selection for enhanced magnetic nanoparticle imaging in magnetorelaxometry10.1118/1.4935147 ↗
31. Long-Term Clearance and Biodistribution of Magnetic Nanoparticles Assessed by AC Biosusceptometry10.3390/ma15062121 ↗
32. Effect of magnetic dipolar interactions on nanoparticle heating efficiency: Implications for cancer hyperthermia10.1038/srep02887 ↗
33. Clinical applications of magnetic nanoparticles for hyperthermia10.1080/02656730802104757 ↗
34. Magnetorelaxometry assisting biomedical applications of magnetic nanoparticles10.1007/s11095-011-0630-3 ↗
35. Nonlinear susceptibility magnitude imaging of magnetic nanoparticles10.1016/j.jmmm.2014.11.049 ↗
36. Superparamagnetic iron oxide nanoparticles: from preparations to in vivo MRI applications10.1039/b902394a ↗
37. Magnetic particle imaging (MPI) for NMR and MRI researchers10.1016/j.jmr.2012.11.029 ↗
38. Enteric coated magnetic HPMC capsules evaluated in human gastrointestinal tract by AC biosusceptometry10.1007/s11095-006-9035-0 ↗