Influence of tensile stress and frequency on the longitudinal magnetic hysteresis of amorphous wires
Source abstract
Abstract
Abstract This work studies the longitudinal magnetic hysteresis of amorphous wires with different Fe or Co compositions through an external magnetic field in the axial direction. Measurements have been carried out with the help of a digitally processed system in the 50 Hz–1 kHz frequency range. In addition, the influence of different tensile stresses has been also analyzed. The results show that both parameters change considerably the magnetic hysteresis of the wires but in a different way depending on their composition. This behaviour has been interpreted in terms of the different domain distribution associated with the opposite sign of the magnetostriction for Fe and Co-based wires, respectively.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metallic Glasses and Amorphous Alloys · Magnetic Properties and Applications · Magnetic properties of thin films
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Vázquez · Physica B · 2001 · 299 · 30210.1016/S0921-4526(01)00482-3 ↗
2. Advanced magnetic microwires
3. Reininger · J. Appl. Phys. · 1993 · 73 · 535710.1063/1.353730 ↗
4. Chiriac · Phys. Rev. B · 2007 · 76 · 21443310.1103/PhysRevB.76.214433 ↗
5. Chiriac · Prog. Mater. Sci. · 1996 · 40 · 33310.1016/S0079-6425(97)00001-7 ↗
6. Chen · J. Phys. D · 1995 · 28 · 102210.1088/0022-3727/28/6/002 ↗
7. Aragoneses · J. Phys. D · 1998 · 31 · 49410.1088/0022-3727/31/5/005 ↗
8. Varga · Phys. Rev. Lett. · 2005 · 94 · 01720110.1103/PhysRevLett.94.017201 ↗