journal article·2001-05

The use of thermomagnetic analysis for detection and quantification of 475°C embrittlement of duplex stainless steels

M.R da Silva, S.S.M Tavares, D Fruchart, S Miraglia, J.M Neto

Publisher page

Abstract

Abstract A duplex stainless steel was aged at 475°C for different times up to 500 h. The thermal embrittlement was investigated by thermomagnetic analysis using a vibrating sample magnetometer and a thermomagnetic balance. The results obtained with the two equipment were similar and show that the Curie temperature increases with the ageing time. Relationships between T c and mechanical properties (hardness and toughness) were proposed.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Microstructure and Mechanical Properties of Steels · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (7)

Show source-provided references
1. Solomon · Acta Metallurgica · 1978 · 26 · 42910.1016/0001-6160(78)90169-4 ↗
2. Mathew · Mater. Sci. Eng. A · 1999 · 269 · 18610.1016/S0921-5093(99)00140-9 ↗
3. M. Hedin, J.P. Massoud, F. Danoix, J. Phys. IV–Colloq. C5 (6) (1996) C5-235.10.1051/jp4:1996538 ↗
4. Tsuchiya · JSME Int. J. A · 1995 · 38 · 384
5. Evanson · J. Eng. Mater Tech. · 1992 · 114 · 410.1115/1.2904138 ↗
6. Kim · Y. J. Korean Nucl. Soc. · 1997 · 29 · 361
7. Annual Book of ASTM Standards, Designation E-23-94b, 1995 p. 137.