journal article·2022-12

Improvement in magnetic nanoparticle tomography estimation accuracy by combining sLORETA and non-negative least squares methods

Teruyoshi Sasayama, Naoki Okamura, Kohta Higashino, Takashi Yoshida

Publisher page

Abstract

Imaging methods that can detect biofunctionalized magnetic nanoparticles (MNPs) accumulated at cancerous tumor sites are expected to be part of the in vivo cancer diagnostic techniques. An imaging technique called magnetic nanoparticle tomography (MNT), which uses a magnetic sensor array, has been proposed. High sensitivity and spatial resolution were achieved using the non-negative least-squares (NNLS) inverse solution in MNT. However, owing to the presence of measurement noise, the concentration and position of certain MNPs were estimated inaccurately, i.e., artifacts were generated. To overcome this issue, this study first applied standardized low-resolution brain electromagnetic tomography (sLORETA), a spatial filter method with no location bias, to approximate the position of MNPs. The region of analysis was restricted to where the estimated value exceeded the threshold. Subsequently, the NNLS method was applied to estimate the concentration and position of MNPs in the restricted region. In the experiment, two Resovist MNP samples (300 or 500 μgFe) were arranged at a distance of 25 – 50 2 mm, and the concentration and position estimation were performed. The estimation results demonstrated that the proposed method successfully suppresses artifacts and adequately estimates the concentration and position of MNPs within a position error of 10 mm and a concentration error of 20 %.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Electrical and Bioimpedance Tomography

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. Biosensing utilizing magnetic markers and superconducting quantum interference devices10.1088/1361-6668/aa5fce ↗
2. Progress in applications of magnetic nanoparticles in biomedicine10.1088/0022-3727/42/22/224001 ↗
3. Were magnetic materials useful in cancer therapy?10.1016/j.biopha.2021.112321 ↗
4. Tomographic imaging using the nonlinear response of magnetic particles10.1038/nature03808 ↗
5. 2012
6. Magnetic particle imaging (MPI) for NMR and MRI researchers10.1016/j.jmr.2012.11.029 ↗
7. Magnetic particle imaging using linear magnetization response-driven harmonic signal of magnetoresistive sensor
8. Three-dimensional magnetic nanoparticle imaging using small field gradient and multiple pickup coils10.1016/j.jmmm.2016.10.107 ↗
9. Magnetostimulation limits in magnetic particle imaging10.1109/TMI.2013.2260764 ↗
10. PNS limits for human head-size MPI systems: preliminary results
11. Two-dimensional magnetic nanoparticle imaging using multiple magnetic sensors based on amplitude modulation10.1016/j.jmmm.2020.166765 ↗
12. Sensitivity improvement of magnetic nanoparticle imaging by compensation with digital-to-analog converter10.1109/TMAG.2020.3014375 ↗
13. Inverse problem analysis in magnetic nanoparticle tomography using minimum variance spatial filter10.1109/TMAG.2021.3078748 ↗
14. Application of square-wave inverter in excitation system for magnetic nanoparticle tomography10.1063/9.0000266 ↗
15. Localization of brain electrical activity via linearly constrained minimum variance spatial filtering10.1109/10.623056 ↗
16. Sekihara · 2008
17. Standardized low resolution brain electromagnetic tomography (sLORETA): technical details
18. Localization bias and spatial resolution of adaptive and nonadaptive spatial filters for MEG source reconstruction10.1016/j.neuroimage.2004.11.051 ↗
19. CVX: MATLAB Software for Disciplined Convex Programming Version 2.2. Accessed: July. 1, 2022. [Online]. Available: http://cvxr.com/cvx/.