2D magnetic nanoparticle imaging using magnetization response second harmonic
Source abstract
Abstract
Abstract A detection method and an imaging technique for magnetic nanoparticles (MNPs) have been investigated. In MNP detection and in magnetic particle imaging (MPI), the most commonly employed method is the detection of the odd harmonics of the magnetization response. We examined the advantage of using the second harmonic response when applying an AC magnetic modulation field and a DC bias field. If the magnetization response is detected by a Cu-wound-coil detection system, the output voltage from the coil is proportional to the change in the flux, dϕ/dt . Thus, the dependence of the derivative of the magnetization, M , on an AC magnetic modulation field and a DC bias field were calculated and investigated. The calculations were in good agreement with the experimental results. We demonstrated that the use of the second harmonic response for the detection of MNPs has an advantage compared with the usage of the third harmonic response, when the Cu-wound-coil detection system is employed and the amplitude of the ratio of the AC modulation field and a knee field H ac / H k is less than 2. We also constructed a 2D MPI scanner using a pair of permanent ring magnets with a bore of ϕ 80 mm separated by 90 mm. The magnets generated a gradient of G z =3.17 T/m transverse to the imaging bore and G x =1.33 T/m along the longitudinal axis. An original concentrated 10 μl Resovist solution in a ϕ 2×3 mm 2 vessel was used as a sample, and it was imaged by the scanner. As a result, a 2D contour map image could be successfully generated using the method with a lock-in amplifier.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Geomagnetism and Paleomagnetism Studies · Minerals Flotation and Separation Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Tomographic imaging using the nonlinear response of magnetic particles10.1038/nature03808 ↗
2. Multidimensional x-space magnetic particle imaging10.1109/TMI.2011.2125982 ↗
3. Magnetic particle detection by frequency mixing for immunoassay applications10.1016/j.jmmm.2006.10.1164 ↗
4. 2d model-based reconstruction for magnetic particle imaging10.1118/1.3271258 ↗
5. , Detection of magnetic nanoparticles using the second-harmonic signal10.1109/TMAG.2011.2157805 ↗
6. A biosensor based on magnetoresistance technology10.1016/S0956-5663(98)00037-2 ↗
7. Superparamagnetic nanoparticle detection using second harmonic of magnetization response10.1063/1.4820447 ↗
8. Frequency distribution of the nanoparticle magnetization in the presence of a static as well as a harmonic magnetic field10.1118/1.2903449 ↗