Magneto-impedance properties of thin-film type sensors using CoNbZr/SiO2 multilayer films
Source abstract
Abstract
Abstract Thin-film magneto-impedance (MI) sensors have attracted much attention because of their advantages such as high sensitivity at room temperature and ease of miniaturization. However, further improvement in their sensitivity is required for detecting weak biomagnetic signals such as the magnetic fields of the brain. Since the high-frequency permeability of magnetic multilayer films with insulator layers improves due to the reduction in eddy current loss in the films, sensors using such multilayer films are expected to show a larger impedance change. In this paper, we fabricated sensors using Co85Nb12Zr3/SiO2 multilayer films and investigated their properties to evaluate the effect of their use on the sensor properties. The high-frequency permeability of the multilayer films improved as compared with that of CoNbZr single-layer films due to the reduction in eddy current loss. Because of the improvement in the permeability, the maximum impedance change ratio (ΔZ/Z) of the sensors using the multilayer films increased from 140% to 280% as compared with that of the sensor using the single-layer films. Thus, the use of magnetic multilayer films is effective for increasing the ΔZ/Z value of MI sensors.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnetic properties of thin films · Magnetic Properties and Applications · Metallic Glasses and Amorphous Alloys
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. Magneto-impedance effect in amorphous wires10.1063/1.112104 ↗
2. Giant magneto-impedance effect in layered thin films10.1109/20.620448 ↗
3. Theory of giant magneto-impedance in the planar conductor with uniaxial magnetic anisotropy10.1016/S0304-8853(99)00286-3 ↗
4. Directivity and sensitivity of high-frequency carrier type thin-film magnetic field sensor10.1016/S0924-4247(99)00096-5 ↗
5. A thin film magnetic field sensor of sub-pT resolution and magnetocardiogram (MCG) measurement at room temperature10.1016/j.jmmm.2008.11.083 ↗
6. Thin-film magneto-impedance structures with very large sensitivity10.1016/j.jmmm.2015.07.107 ↗
7. Analysis of thin-film magnetoimpedance sensor using the variations in impedance and the magnetic domain structure10.1063/1.4863163 ↗
8. High frequency characteristics of a planar inductor and a magnetic coupling control device10.1109/TJMJ.1991.4565180 ↗
9. Initial permeability of amorphous single and multilayered films10.1109/TMAG.1986.1064282 ↗
10. Enhancement of high frequency permeability in amorphous CoNbTi/SiO2 layered films10.1109/TMAG.1986.1064517 ↗
11. Role of various spacer materials on magnetic properties of CoNbZr amorphous multilayered thin films10.3379/jmsjmag.15.S2_131 ↗
12. Magnetic softness and domain wall structures of double-layered amorphous Co-Zr-Nb films10.1143/JJAP.25.419 ↗
13. Analysis of the high-frequency impedance of micromachined films10.3379/jmsjmag.21.789 ↗