article·2013-09-30Open access

Implementation of a Modified SQI for the Preprocessing of Magnetic Flux Leakage Signal

Bok-Jin Oh, Doo-Hyun Choi

Abstract

A modified SQI method using magnetic leakage flux (MFL) signal for underground gas pipelines ’ defect detection and characterization is presented in this paper. Raw signals gathered using MFL signals include many unexpected noises and high frequency signals, uneven background signals, signals caused by real defects, etc. The MFL signals of defect free pipelines primarily consist of two kinds of signals, uneven low frequency signals and uncertain high frequency noises. Leakage flux signals caused by defects are added to the case of pipelines having defects. Even though the SQI (Self Quotient Image) is a useful tool to gradually remove the varying backgrounds as well as to characterize the defects, it uses the division and floating point operations. A modified SQI having low computational complexity without time-consuming division operations is presented in this paper. By using defects carved in real pipelines in the pipeline simulation facility (PSF) and real MFL data, the performance of the proposed method is compared with that of the original SQI
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Blind Source Separation Techniques · Water Systems and Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.