journal article·2026-08-01

Applicability of 5× maximum permissible exposure limit for near-infrared laser directed energy weapon hazard zones

Dominik Pudo, Semih Kumru, David Sliney

Journal of Laser Applications· Volume 38· Issue 3
Publisher page

Abstract

The authors review the underlying safety aspects of maximum permissible exposure (MPE), defined as the level of laser radiation to which an unprotected person may be exposed without adverse biological changes in the eye or skin, in laser safety, as well as the rationale behind the Class 3R laser classification so as to propose using a more relaxed exposure guideline for the use of laser directed energy weapons. Based on the unique constraints applicable to laser weapons as well as the inherent safety factor built into the maximum permitted exposure, the authors recommend allowing 5× MPE as the hazard zone guideline.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular and Laser Science Research · Traumatic Ocular and Foreign Body Injuries · Optical Systems and Laser Technology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Defence Research and Development Canada—Valcartier Research Centre 1 , Quebec, Quebec G1X4Y1,

U.S. Air Force Laboratory 2 , San Antonio, Texas 78235

Consulting Medical Physicist 3 , Fallston, Maryland 21047

References (19)

Show source-provided references
1. Evaluating health hazards from military lasers10.1001/jama.1970.03180060025005 ↗
2. Computational modeling and damage threshold prediction of continuous-wave and multiple-pulse porcine skin laser exposures at 1070 nm10.2351/7.0000367 ↗
3. Comparison of laser induced corneal injury thresholds with safety limits for the wavelength range of 1200–1500 nm10.2351/7.0001375 ↗
4. What is the meaning of threshold in laser injury experiments? Implications for human exposure limits10.1097/00004032-200203000-00006 ↗
5. Real-time temperature determination during retinal photocoagulation on patients10.1117/1.JBO.17.6.061219 ↗
6. Non-contact in vivo measurement of ocular microtremor using laser speckle correlation metrology10.1088/0967-3334/35/7/1229 ↗
7. Probabilistic laser safety: Ocular damage models for Q-switched neodymium and ruby lasers10.1097/00004032-199404000-00006 ↗
8. Retinal light toxicity10.1038/eye.2010.149 ↗
9. Pupil size in outdoor environments10.1097/HP.0000000000000887 ↗
10. 1985
11. The history of Class 3A—A review10.2351/1.5056879 ↗
12. Measured statistics of laser beam scintillation in strong refractive turbulence relevant to eye safety10.1097/00004032-198712000-00007 ↗
13. Laser safety evaluation for high-energy laser interaction with solids10.1117/1.OE.56.2.026106 ↗
14. Reflection measurements in TNO’s 30 kW laser facility10.1117/12.2634047 ↗
15. Creation and use of probabilistic dynamic bidirectional reflectance distribution functions
16. Laser safety assessments supported by analyses of reflections from metallic targets irradiated by high-power laser light10.1364/AO.424722 ↗
17. Probability and risk in laser safety10.2351/1.4745344 ↗
18. Probabilistic laser safety: Ocular damage models for Q-switched neodymium and ruby lasers10.1097/00004032-199404000-00006 ↗
19. Probabilistic risk assessment modelling for laser directed energy weapon systems10.2351/7.0001439 ↗