journal article·2020-08-01

Validation of a generalized laser safety analysis method for irregular pulse trains

Mathieu Jean, Karl Schulmeister, Sebastian Kotzur, Annette Frederiksen

Journal of Laser Applications· Volume 32· Issue 3
Publisher page

Abstract

The current laser safety standards do not address specifically how to account for repetitively pulsed lasers with irregular pulse trains. Variations in peak power, pulse duration, and duty cycle within a pulse train pose a number of problems when it comes to product classification or to assess the hazard of a given exposure. This study proposes to analyze irregular pulse trains by generalizing the determination of the number of pulses N used in the IEC 60825-1 or n in the ANSI Z136.1 standard. The proposed method for the determination of N applies to emission durations longer than 5 μs and was validated by generating a large number of theoretical pulse patterns and by comparing the retinal injury threshold, determined with a computer model, with the applicable emission limit. For 18 000 different pulse patterns, the ratio of the injury threshold to the emission limit was never less than 2, which is commonly considered as a sufficient safety margin. The smallest safety margin found for regular pulse patterns also equals 2. This study validates an analysis method for irregular pulse trains that can be included in the standards by simple generalization of the determination of the parameter N.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular and Laser Science Research · Laser Material Processing Techniques · Advanced Optical Sensing Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Seibersdorf Labor GmbH, Laser, LED and Lamp Safety 1 , 2444 Seibersdorf, Austria

Robert Bosch GmbH, Corporate Research 2 , 71272 Renningen, Germany

Institute for Ophthalmic Research, Eberhard Karls University of Tübingen 3 , 72076 Tübingen, Germany

Robert Bosch GmbH, Chassis Systems Control 4 , 71701 Schwieberdingen, Germany

References (15)

Show source-provided references
1. International Electrotechnical Commission · 2014
2. American National Standards Institute, ANSI Z136.1-2014 · 2014
3. 2016
4. 2015
5. International Electrotechnical Commission · 2017
6. 2015
7. 2017
8. Optical detection of intracellular cavitation during selective laser targeting of the retinal pigment epithelium10.1117/1.2804078 ↗
9. ICNIRP guidelines on limits of exposure to laser radiation of wavelengths between 180 nm and 1000 μm10.1097/HP.0b013e3182983fd4 ↗
10. Validation of a computer model to predict laser induced retinal injury thresholds10.2351/1.4997831 ↗
11. What is the meaning of threshold in laser injury experiments?10.1097/00004032-200203000-00006 ↗
12. 2000
13. Ocular hazards of Q-switched blue wavelength lasers10.1117/12.426722 ↗
14. Ocular susceptibility to laser radiation: Human vs. rhesus monkey
15. 2018