journal article·2008-05-01

New data on the variation of laser induced retinal-damage threshold with retinal image size

J. A. Zuclich, P. E. Edsall, D. J. Lund, B. E. Stuck, S. Till, R. C. Hollins, P. K. Kennedy, L. N. McLin

Journal of Laser Applications· Volume 20· Issue 2
Publisher page

Abstract

In earlier studies, we examined the dependence of the laser induced retinal damage threshold on retinal image size for extended-source ocular exposures. We reported the spot-size dependence of the retinal threshold (based on ophthalmic observations at 24 h postexposure) for two pulsewidth regimes: nanosecond-duration (Q-switched) pulses from a doubled Nd:yttrium–aluminum–garnet laser and microsecond-duration pulses from a flashlamp-pumped dye laser at 590 nm. In either case, the retinal threshold was shown to vary with the area (i.e., diameter squared) for image diameters >5 mrad. More recently, we have collected additional data for the intermediate spot-size range (1.5–10 mrad) and have compared both the absolute values and the spot-size trend of retinal thresholds determined via ophthalmoscopic observation at 1 h postexposure to the analogous threshold data collected with observations at 24 h postexposure. These additional data and analyses reinforce our earlier conclusions regarding the threshold vs. spot-size trend and are compared to and reconciled with results from previously published extended-source ocular damage studies. The experimental spot-size trends are also contrasted to the existing laser safety standard treatments of maximum permissible exposure levels for extended-source ocular exposures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular and Laser Science Research · Retinal Development and Disorders · Visual perception and processing mechanisms

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Northrop Grumman IT, 4241 Woodcock Dr., Suite B-100, San Antonio, Texas 78228-1330

US Army Medical Research Detachment, Brooks AFB, Texas 78235-5138

UK Dstl, Malvern, WR 143PS, United Kingdom

Optical Radiation Branch, USAF/HEDO, Brooks AFB, Texas 78235-5215

References (21)

Show source-provided references
1. Experimental study of the variation of laser-induced retinal damage threshold with retinal image size
2. Laser induced retinal-damage as a function of retinal image size10.1117/12.350594 ↗
3. Variation of laser induced retinal-damage threshold with retinal image size10.2351/1.521917 ↗
4. Eye protection of military personnel from laser radiation
5. Eye protection of military personnel from laser radiation
6. Optical limiter development
7. Nonlinear optical properties of carbon-black suspensions (ink)10.1364/JOSAB.9.001100 ↗
8. Nonlinear refraction and optical limiting in thick media10.1117/1.2169698 ↗
9. A review of optical limiting mechanisms and devices using organics, fullerenes, semiconductors and other materials10.1016/0079-6727(93)90004-S ↗
10. Materials for optical limiting
11. 1980
12. Interaction mechanisms of laser radiation with ocular tissues
13. 1990 · 25
14. American National Standard for the Safe Use of Lasers
15. Safety of Laser Products - Part 1: Equipment, classification, requirements and user’s guide
16. Melanin granule model for heating of tissue by laser
17. Melanin granule model for laser-induced thermal damage in the retina10.1016/0092-8240(95)00360-6 ↗
18. Parameter sensitivity of the Thompson granular retinal damage model10.1117/12.308160 ↗
19. Visible lesion threshold dependence on retinal spot size for femtosecond laser pulses10.2351/1.1356421 ↗
20. Variation of laser-induced retinal injury thresholds with retinal irradiated area: 0.1 s duration 514 nm exposures10.1117/1.2714810 ↗
21. Ex-plant retinal laser induced threshold studies in the millisecond time regime