New data on the variation of laser induced retinal-damage threshold with retinal image size
Source abstract
Abstract
In earlier studies, we examined the dependence of the laser induced retinal damage threshold on retinal image size for extended-source ocular exposures. We reported the spot-size dependence of the retinal threshold (based on ophthalmic observations at 24 h postexposure) for two pulsewidth regimes: nanosecond-duration (Q-switched) pulses from a doubled Nd:yttrium–aluminum–garnet laser and microsecond-duration pulses from a flashlamp-pumped dye laser at 590 nm. In either case, the retinal threshold was shown to vary with the area (i.e., diameter squared) for image diameters >5 mrad. More recently, we have collected additional data for the intermediate spot-size range (1.5–10 mrad) and have compared both the absolute values and the spot-size trend of retinal thresholds determined via ophthalmoscopic observation at 1 h postexposure to the analogous threshold data collected with observations at 24 h postexposure. These additional data and analyses reinforce our earlier conclusions regarding the threshold vs. spot-size trend and are compared to and reconciled with results from previously published extended-source ocular damage studies. The experimental spot-size trends are also contrasted to the existing laser safety standard treatments of maximum permissible exposure levels for extended-source ocular exposures.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ocular and Laser Science Research · Retinal Development and Disorders · Visual perception and processing mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Northrop Grumman IT, 4241 Woodcock Dr., Suite B-100, San Antonio, Texas 78228-1330
US Army Medical Research Detachment, Brooks AFB, Texas 78235-5138
UK Dstl, Malvern, WR 143PS, United Kingdom
Optical Radiation Branch, USAF/HEDO, Brooks AFB, Texas 78235-5215
References (21)
Show source-provided references
1. Experimental study of the variation of laser-induced retinal damage threshold with retinal image size
2. Laser induced retinal-damage as a function of retinal image size10.1117/12.350594 ↗
3. Variation of laser induced retinal-damage threshold with retinal image size10.2351/1.521917 ↗
4. Eye protection of military personnel from laser radiation
5. Eye protection of military personnel from laser radiation
6. Optical limiter development
7. Nonlinear optical properties of carbon-black suspensions (ink)10.1364/JOSAB.9.001100 ↗
8. Nonlinear refraction and optical limiting in thick media10.1117/1.2169698 ↗
9. A review of optical limiting mechanisms and devices using organics, fullerenes, semiconductors and other materials10.1016/0079-6727(93)90004-S ↗
10. Materials for optical limiting
11. 1980
12. Interaction mechanisms of laser radiation with ocular tissues
13. 1990 · 25
14. American National Standard for the Safe Use of Lasers
15. Safety of Laser Products - Part 1: Equipment, classification, requirements and user’s guide
16. Melanin granule model for heating of tissue by laser
17. Melanin granule model for laser-induced thermal damage in the retina10.1016/0092-8240(95)00360-6 ↗
18. Parameter sensitivity of the Thompson granular retinal damage model10.1117/12.308160 ↗
19. Visible lesion threshold dependence on retinal spot size for femtosecond laser pulses10.2351/1.1356421 ↗
20. Variation of laser-induced retinal injury thresholds with retinal irradiated area: 0.1 s duration 514 nm exposures10.1117/1.2714810 ↗
21. Ex-plant retinal laser induced threshold studies in the millisecond time regime