journal article·2001-08-01

A procedure for multiple-pulse maximum permissible exposure determination under the Z136.1-2000 American National Standard for Safe Use of Lasers

Robert J. Thomas, Benjamin A. Rockwell, Wesley J. Marshall, Robert C. Aldrich, Sheldon A. Zimmerman, R. James Rockwell

Journal of Laser Applications· Volume 13· Issue 4
Publisher page

Abstract

The current national consensus standard for laser safety in the United States is the American National Standard for Safe Use of Lasers (ANSI Z136.1). Over the past few years, a comprehensive rewrite of this standard has been conducted. The updated version of the standard (Z136.1-2000) incorporates a wealth of new bioeffects data and establishes a number of new maximum permissible exposure (MPE) limits for laser safety. The updated standard also includes new procedures for the computation of MPE values, which must be understood by health physicists, laser safety officers, and others in the field of occupational safety. Here we present the first in a series of tutorial articles to clarify laser safety analysis procedures under this new standard. This article deals with the proper application of three rules for determining the appropriate MPE values for repetitively pulsed lasers or repeated exposures from laser beams.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular and Laser Science Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Air Force Research Laboratory, Brooks AFB, Texas 78235-5415

USACHPPM, Aberdeen Proving Ground, Maryland 21010-5422

Dahlgren Division, Naval Surface Warfare Center, Dahlgren, Virginia 22448-5100

Rockwell Laser Industries, Cincinnati, Ohio 45243

References (7)

Show source-provided references
1. Proposed maximum permissible exposure limits for ultrashort laser pulses10.1097/00004032-199904000-00002 ↗
2. Retinal image motion during deliberate fixation: Implications to laser safety for long duration viewing10.1097/00004032-200002000-00002 ↗
3. Revision of guidelines on limits of exposure to laser radiation of wavelengths between 400 nm and 1.4 μm10.1097/00004032-200010000-00013 ↗
4. Thresholds for visible lesions in the primate eye produced by ultrashort near-infrared laser pulses
5. Visible retinal lesions from ultrashort laser pulses in the primate eye
6. Update on ANSI Z136.110.2351/1.521898 ↗
7. Laser hazard evaluation method for middle infrared laser systems10.2351/1.4745424 ↗